Built-in Test Program 

 

The Finalizer Express has a Built-in Test Program. To run the program; Press the BYPASS button while powering on. Each test has a number which is displayed in the FINALIZE LED 
matrix. Use the left and right arrow buttons to select between the tests. Use the FINALIZE SOFTCLIP button to execute/leave a test. 

 To leave the Built-in Test Program; turn off the power. 

 

Finalizer Express Built-in-Test Program has following tests: 

No. 

TEST 

Function / Comments 

LED test 

Turns on all LEDs. If no light; check soldering at the LED and at the flat cables between the front boards. 

Test of pots  

This test is used for calibration of the pots. All pots must be set in middle position. If any of the pots are outside the specified range, a minus " -" will be 
shown and the LED above the faulty pot will flash. A Plus "+" confirms that all controls are within the specified range. If new pots are mounted the new 
values can be stored by pressing the SELECT INPUT button.  "+" confirms the new values were stored succesfully. 

Analog I/O test 

A sine wave is generated on both analog outputs. When connected directly to one of the analog inputs the LED matrix should read "+". 

Note: When running this test the input Meter must show -12dB for the channel on test. 
Note: In case of defective IC35,  IC36, IC41  they should be replaced with type MC33079 

AES I/O test 

A digital signal is generated on the AES/EBU output. When connected directly to the AES/EBU input the display should read "+".  

S/PDIF I/O test 

A digital signal is generated on the S/PDIF output. When connected directly to the S/PDIF input the display should read "+".  

OPTO I/O test 

A digital signal is generated on the OPTO output. When connected directly to the OPTO input the display should read "+".  

Midi I/O 

A midi signal is generated on output. When connected to the input the display reads "+" if the signal is correct. The midi signal from input is sent on to 
MIDI THRU. If  "-" is shown; try with another midi cable or check soldering  and components in the midi circuit. 

EXT. CONTROL 

IN test 

Tests the status on the EXTERNAL CONTROL IN. When no jack plug is inserted the display should read "-". If a jack plug is inserted and the tip of the 
plug is connected to ground, the display should read "+". 

Battery test 

Tests the DC voltage at the Back up battery. If low; check the battery voltage is min +2.9VDC. Check also the standby current by measuring the voltage 
across R27; max. 20mV (numerical value). If the voltage is higher; check IC4, IC8, C35. If necessary; refer to section "exchange of battery" 

System test 

Tests  the MPU, DSP, DARC and SOUND RAM to some extent.  

10 

Ext. FADER 

calibration 

Connect the TC MASTER FADER (or similar) to EXTERNAL CONTROL IN. 
Move the Fader to position MAXimum when the "arrow up" is shown. Then press the FINALIZE SOFTCLIP button. 
Move the Fader to position MINimum when the "arrow down" is shown. Then press the FINALIZE SOFTCLIP button to finish the calibration. 
If the calibration went Ok the display should read "+" 

  

Summary of Contents for Finalizer Epress

Page 1: ...Technical service manual Finalizer Epress...

Page 2: ...ftware Boot Menu 4 Built in Test Program 6 Disassembly Procedure for Main Board 7 Disassembly Procedure for Front Section 8 Exchange of Power Supply Module 10 Exchange of Battery Exchange procedure 11...

Page 3: ...ists and Component Layouts The schematics start with a main sheet where sub sheets are shown as blocks Even sub sheets might have sub sheets In the schematics some connections have label names to help...

Page 4: ...ow keys to check the application software Press the FINALIZE SOFTCLIP key to execute If corrupted load the application software again Or try to run the self test prom see section Built in Test program...

Page 5: ...____________________________________________________________________________________________________________________________________________________ __________________ TC Electronic A S Finalizer Expr...

Page 6: ...case of defective IC35 IC36 IC41 they should be replaced with type MC33079 3 AES I O test A digital signal is generated on the AES EBU output When connected directly to the AES EBU input the display s...

Page 7: ...IF in out connector see fig 3 7 Remove the screws at the ADAT in out connector see fig 3 8 Remove the jack nut at the EXT CONTROL IN connector see fig 3 9 Push the main board into the front profile a...

Page 8: ...de panels by unscrewing 4 screws at each side see fig 4 5 Remove the front section 6 Pull off the seven pot knobs by hand 7 Place the front profile horizontally with the buttons facing down 8 Pull out...

Page 9: ...____________________________________________________________________________________________________________________________________________________ __________________ TC Electronic A S Finalizer Expr...

Page 10: ...pply by removing the screw just below the AC inlet at the back panel see fig 6 8 Mount the new power supply with the screw at the back panel 9 Solder the power wires into the main board see fig 7 10 M...

Page 11: ...d solder the terminals one by one Avoid any short circuit of the terminals 5 The voltage measured directly across the terminals of the new battery should be higher than 3 0VDC 6 Do not discard the old...

Page 12: ...OG INPUTS balanced ANALOG IN GAIN ANALOG OUT GAIN ANALOG OUTPUTS balanced A D Digital Input Select INPUT PPM OUTPUT PPM Left Left Left Right Normalizer Spectral Balance Fader Bypass Right Right Analog...

Page 13: ...o change An attenuator allows the MPU to measure the contrast voltage The PLL circuit placed on a separate board makes a very stable frequency at 256 x sample rate this frequency is divided down to 64...

Page 14: ...LD3 Code explanation Comment Off off off Normal On on on Checksum error in boot software Reload boot software LD4 has two functions 1 Show power on 2 Define clean power for IC33 pin 6 Jumper settings...

Page 15: ...Analog Outputs Connectors XLR balanced pin 2 hot Impedance 100 ohm active transformer Max Output Level 22 dBu balanced Full Scale Output Range 10 dBu to 22 dBu D to A Conversion 24 bit 1 bit 128 time...

Page 16: ...3001 4 14 pages Part list for Main board ver PC13001 4 16 pages PCB lay out for Main board ver PC13001 4 2 pages Schematic for Main board ver PC13001 3 14 pages Part list for Main board ver PC13001 3...

Reviews: