TC3005
(LED/ELED/LASER)
User's Manual
Rev. 3.0
−2−
5.
5.
5.
5.
5.
LEDs, DIP Switches and Connectors
LEDs, DIP Switches and Connectors
LEDs, DIP Switches and Connectors
LEDs, DIP Switches and Connectors
LEDs, DIP Switches and Connectors
Figure 2. TC3005's Rear Panel
Figure 2. TC3005's Rear Panel
Figure 2. TC3005's Rear Panel
Figure 2. TC3005's Rear Panel
Figure 2. TC3005's Rear Panel
Figure 1. TC3005's Front Panel
Figure 1. TC3005's Front Panel
Figure 1. TC3005's Front Panel
Figure 1. TC3005's Front Panel
Figure 1. TC3005's Front Panel
LEDs Functions
LEDs Functions
LEDs Functions
LEDs Functions
LEDs Functions
ALARM Status Indicator-
Alarm Buzzer &
ALM LED Flashing - Indicates that the optical signal is not present or lost at the Multimode and/or
Dry contact Relay:
Single mode receiver(s) and the alarm will be triggered.
ALM LED Off - Indicates the unit is under normal working condition (
receiving good optical signals
).
Alarm Condition:
When the Alarm is triggered, the alarm buzzer will sound & the dry contact relay will close. (
see section 6 on next page
).
Power Supply Status Indicators-
PWR A/B:
When lit, these LEDs indicate which power source on the rear panel the unit is drawing from. If power
redundancy is utilized, both LEDs will be lit.
Vcc:
+5V Voltage indicator. The Vcc LED should light solidly whenever power is connected to the unit.
It indicates the correct operating voltage is being derived from the power source.
Multimode Optic Signal Status Indicators-
MM RX:
Solidly lit, indicates a valid optical signal is received at the MM receiver & it is above sensitivity threshold.
Off, indicates the optical signal at the MM RX is not present, lost, bursty or questionable (not valid).
- Verify that the user’s Multimode device optical wavelength matches that of the TC3005 units.
- Verify the integrity of the Multimode fiber cables and connections.
Single Mode Optic Signal Status Indicators-
SM Rx:
Solidly lit, indicates optical signal at the SM optic receiver is received & it is above sensitivity threshold.
Off, indicates the single mode optical signal at the SM optic receiver is not present or it is lost.
Optical Connectors
Optical Connectors
Optical Connectors
Optical Connectors
Optical Connectors
MM Tx:
Multimode Transmitter (Tx). - Connect to local equipment's MM receiver (Rx).
MM Rx:
Multimode Receiver (Rx). - Connect to local equipment's MM transmitter (Tx).
SM Tx:
Single mode Transmitter (Tx). - Connect to remote unit's SM receiver (Rx).
SM Rx:
Single mode Receiver (Rx). - Connect to remote unit's SM transmitter (Tx).
DIP Switch Functions
DIP Switch Functions
DIP Switch Functions
DIP Switch Functions
DIP Switch Functions
SW1,2,3:
Not used; reserved for future functions.
SW4:
DISALM - Down (or Right) disables the audio buzzer and dry contact relay alarm switch.
Note
:
Keep the "DISALM" dip switch in the Off or "up position" under normal condition.
ALARM
PWR
A
PWR
B
+ -
(12-14 VDC)
@600mA
+ -
1
2
3
4
ON
Made in U.S.A.
Vcc
SM RX
B
A
MM RX
TCCOMM.COM
ALM
PWR
FIBER OPTIC
MODE CONVERTER
Rx
Tx
Rx
Tx
SM
MM
Multimode Transmitter
& Receiver (Tx & Rx)
Not Used. Reserved
for future functions.
Not Used. Reserved
for future functions.
Single mode Transmitter
& Receiver (Tx & Rx)