TC3005

(LED/ELED/LASER)

User's Manual

Rev. 3.0

−1−

1.

1.

1.

1.

1.

Description

Description

Description

Description

Description

The TC3005 gives users the ability to convert Multimode fiber optic signals to Single Mode format for data
transmission (and vice-versa).  These conversions can benefit users by extending transmission distances
and/or enabling dissimilar fiber optic devices to be used with different fiber types.  The optic receiver detects
the incoming optical signal and regenerates it for transmission through the second optic transmitter.  The
TC3005 is available in multiple configurations depending on your communication requirements.  When both
sides have the same wavelength, the TC3005 works like an optical signal repeater.

2.

2.

2.

2.

2.

Data Rates

Data Rates

Data Rates

Data Rates

Data Rates

165Mbps*

*Contact factory for higher data rates.

3.

3.

3.

3.

3.

Optical Specifications

Optical Specifications

Optical Specifications

Optical Specifications

Optical Specifications

Transmitter:

Transmitter:

Transmitter:

Transmitter:

Transmitter:

LED; typical Launch Power:

-16 dBm* (850nm/1310nm, Multimode @62.5/125µm)

ELED; typical Launch Power:

-16 dBm* (1310nm/1550nm, Single Mode @9/125µm)

LASER; typical Launch Power:

-6 dBm* (1310nm/1550nm, Single Mode @9/125µm)

Receiver:

Receiver:

Receiver:

Receiver:

Receiver:

PIN DIODE; typical Sensitivity:

-33 dBm* (850nm/1310nm, Multimode @62.5/125µm)

-33 dBm* (1310nm/1550nm, Single Mode @9/125µm)

-36 dBm* (1310nm/1550nm, Single Mode @9/125µm)

Loss Budget:

Loss Budget:

Loss Budget:

Loss Budget:

Loss Budget: LED; 850nm/1310nm, MM @62.5/125µm

16 dB

ELED; 1310nm/1550nm, SM @9/125µm

16 dB

LASER; 1310nm/1550nm, SM @9/125µm

25 dB

Distance:

Distance:

Distance:

Distance:

Distance:

850nm, Multimode @62.5/125µm

up to 3km*

1310nm, Multimode @62.5/125µm up to 4km*

1310nm, Single Mode @9/125µm up to 40km*

1550nm, Single Mode @9/125µm up to 110km*

Wavelength:

Wavelength:

Wavelength:

Wavelength:

Wavelength:

Note: Any two wavelength combinations are available on each unit.

850nm Multimode (LED)

1310nm Multimode (LED)

1310nm Single Mode (ELED/LASER)

1550nm Single Mode (ELED/LASER)

Connector:

Connector:

Connector:

Connector:

Connector:

ST, FC, or SC

*Launch power, sensitivity and distance are listed for reference only.  These numbers may vary. Contact

factory for higher loss budgets.

© COPYRIGHT 1992-2010.  ALL RIGHTS RESERVED.

TC Communications, Inc.  17881 Cartwright Road - Irvine, CA  92614

Tel: (949) 852-1972   Fax: (949) 852-1948   Web Site: www.tccomm.com   Email: [email protected]

4.

4.

4.

4.

4.

Power Requirements

Power Requirements

Power Requirements

Power Requirements

Power Requirements

A.

The TC3005 consumes very low power.  The connector is a terminal block with polarity indicated on the
rear panel of the unit (see Figure 2).  The input voltage is typically 12 VDC and current is @600mA.  The
unit can be ordered with optional power options: 24 VDC@300mA, 48 VDC@150mA, or 115/230 VAC
with an external power adapter.

B .

Should an external power adapter need to be replaced, use one that matches the above specifications.
You may order it from TC Communications.

C.

There are two pairs of terminal block connectors on the rear panel (labeled "PWR A" and "PWR B").
Only one pair is required to power the unit.  If both pairs are connected, the built-in power redundancy
feature will be utilized.  When this feature is utilized, both "A" and "B" share the load.  If one power source
fails, the other will assume the full load.

165Mbps Fiber Optic Mode Converter/Repeater

165Mbps Fiber Optic Mode Converter/Repeater

165Mbps Fiber Optic Mode Converter/Repeater

165Mbps Fiber Optic Mode Converter/Repeater

165Mbps Fiber Optic Mode Converter/Repeater

TC3005(LED/ELED/LASER)

TC3005(LED/ELED/LASER)

TC3005(LED/ELED/LASER)

TC3005(LED/ELED/LASER)

TC3005(LED/ELED/LASER)

User's Manual

User's Manual

User's Manual

User's Manual

User's Manual

Summary of Contents for TC3005

Page 1: ...550nm SingleMode 9 125µm up to 110km Wavelength Wavelength Wavelength Wavelength Wavelength Note Any two wavelength combinations are available on each unit 850nmMultimode LED 1310nmMultimode LED 1310nmSingleMode ELED LASER 1550nmSingleMode ELED LASER Connector Connector Connector Connector Connector ST FC or SC Launch power sensitivity and distance are listed for reference only These numbers may v...

Page 2: ...tors MMRX Solidly lit indicates a valid optical signal is received at the MM receiver it is above sensitivity threshold Off indicates the optical signal at the MM RX is not present lost bursty or questionable not valid Verify that the user s Multimode device optical wavelength matches that of the TC3005 units Verify the integrity of the Multimode fiber cables and connections Single Mode Optic Sign...

Page 3: ... for the dry contact relay alarm see Figure 2 Normally in the OPEN position the loss of either optic signal will trigger an alarm condition and force the switch to the CLOSED position This relay can be used in conjunction with an external device to monitor the condition of the fiber optic links Note If SW4 DISALM on the front panel is in the Down position the audio buzzer will not sound and the dr...

Page 4: ...ion permanently insert a 5dB or 10dB in line attenuator into the problem link In line attenuators can be purchased from Metrotek at 727 547 8307 The part numbers are Description Description Description Description Description ST 5dB ST 5dB ST 5dB ST 5dB ST 5dB ST 10dB ST 10dB ST 10dB ST 10dB ST 10dB FC 5dB FC 5dB FC 5dB FC 5dB FC 5dB FC 10dB FC 10dB FC 10dB FC 10dB FC 10dB PartNumber PartNumber Pa...

Page 5: ...all bear the risk of loss until all goods authorized to be returned are delivered to TC Communications Inc TC Communications Inc shall not be liable for any inspection packing or labor costs in connection with the return of goods In the event that TC Communications Inc breaches its obligation of warranty the sole and exclusive remedy of the Buyer is limited to replacement repair or credit of the p...

Reviews: