10
Notes:
•
The solar charger can be installed in a positive or in a negative grounded system. In a vehicle
for example, always apply a short single ground connection, ideally close to the battery, to
avoid ground loops that could cause system instabilities.
•
Please check the table below for maximum PV and battery current levels plus advised
minimum cable sizes:
Charger
model
PV max. input
current
Min.PV wire
size
Battery max.
charge current
Min. battery
wire size
OCS 150-60
50A
16mm
2
60A
16mm
2
OCS 250-70
40A
10mm
2
70A
16mm
2
•
Please check the next table for battery fuse recommendations:
Charger model
Min. fuse rating
Max. fuse rating
OCS 150-60
70A
85A
OCS 250-70
85A
100A
•
When the battery temperature sensor is connected to the solar charger to enable
temperature compensated charging, please make sure that this sensor is located as close as
possible to the battery. When no temperature sensor is connected to the solar charger,
charge voltages will not be compensated against varying temperature.