background image

 
 

 

 

Installation Manual for TBS readers: 

 

2D IRON and 3D AIR 

Document TBS-056-057

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

NOTE: 

The latest version of this document is always available at: 

https://cloud1.tbs-biometrics.com/index.php/s/IcgqtcdZXJVBrzA

  

 

 

 

Revision 

Author 

New content 

Oct 22, 2021 

AG/TO 

First Release 

April 13, 2022 

AG/TO 

Minor updates 

Aug 18, 2022 

AG 

Name changes 

Nov 20, 2023 

AG 

Port assignments for BME, device front closing, FM box dimensions 

Summary of Contents for 2D IRON

Page 1: ...of this document is always available at https cloud1 tbs biometrics com index php s IcgqtcdZXJVBrzA Revision Author New content Oct 22 2021 AG TO First Release April 13 2022 AG TO Minor updates Aug 18...

Page 2: ...3 Mounting Instructions 9 4 3 1 Preparation 9 4 3 2 Wall Mount Box 9 4 3 3 Heavy Duty Box IP65 10 4 3 4 Flush Mount Box IP54 11 5 Power and Signal Wiring 12 5 1 Electrical Connection and Cabling 12 5...

Page 3: ...TBS 056 ICL WM HID PROX TBS 056 PRO WM Legic Mifare Classic or Desfire TBS 056 LEM WM Wall Mount Heavy Duty IP65 none TBS 056 STD HD HID iClass TBS 056 ICL HD HID PROX TBS 056 PRO HD Legic Mifare Cla...

Page 4: ...of our appliances must be carried out when disconnected from the power supply in particular appliances that are normally supplied by low voltage current It is prohibited to alter the device or to remo...

Page 5: ...nditions 1 the device may not cause harmful interference and 2 the device must accept any interference received including interference that may cause undesired operation Changes or modifications not e...

Page 6: ...ng temperature 20 to 60 C Relative humidity 10 to 90 Outdoor device use is not compliant with UL294 In the case of 3D AIR strong ambient light and or direct light into the sensor of the terminal shoul...

Page 7: ...ame for all three mounting variants wall mount heavy duty wall mount flush mount 4 2 1 Opening the Device IMPORTANT Always disconnect power supply before opening terminals Unlock 1 Use Allen wrench si...

Page 8: ...Allen wrench size 3 to lock front part to back cover Screw in fully and turn back half a turn IMPORTANT To avoid destruction and electrical shorts please ensure no cable or metal parts press against t...

Page 9: ...the installation for the passage of cables Make sure that the installation wall is completely flat to allow a nice and proper mounting TBS provides very accurately manufactured enclosures that only fi...

Page 10: ...he heavy duty variant Four 4 5mm screws and fitting raw plugs suitable for the wall material not included One screwdriver appropriate to drive the above screws One drill with a drill bit of an appropr...

Page 11: ...t a rectangular shape with dimensions of 204 x 127 mm height x width as in the two pictures These dimensions include 1 5 mm air spacing all around the box It is not required to cut the precise box dim...

Page 12: ...of the wire terminal before removing the cable to unlock the latch NOTE Removing cables with force from the wire terminal may damage the wire terminal or the board Unlock the latches before removing...

Page 13: ...wer supply to the terminal can also be provided by Ethernet using RJ45 connection Power over Ethernet IEEE802 3af compliant TBS recommends using an ethernet cable of Cat5e standard or higher The termi...

Page 14: ...age to the input line For each input independently the desired operating mode is selected by inserting or removing a resistor to a respective GP IN pull up resistor socket on the mainboard Resistor is...

Page 15: ...activate security access equipment For such TBS offers two dedicated controllers 5 6 Connecting TBS Controllers For various applications TBS Terminals need to be connected with external controllers e...

Page 16: ...pen Closes when the tamper switch is activated C Common 30 VDC 1A 220 VDC 0 14 A 120 VDC 0 25 A 250 VAC 0 12 A NC Normally Closed Opens when the tamper switch is activated A recommended way of utilizi...

Page 17: ...ring regular usage Special tests to check for correct functioning are therefore not required TBS recommends checking the integrity of the sensor surfaces and openings of the terminals at least every 6...

Page 18: ...unication with reader failed Shutdown and re power the device 423 RFID card reading error 430 Unknown Relay GPIO error 431 Relay GPIO communication error 440 General problem with external verification...

Page 19: ...8 HTTPS communication channel to BME server and Device Control Center DCC No Yes Enrollment API 8281 8282 8284 HTTP S communication channel between enrollment components Yes 2 No 8283 MQTT Enrollment...

Page 20: ...T Enrollment PC WE channel 1 80 443 HTTP S communication channel to WE server and Device Control Center DCC No Yes Series12 terminal WebEdition 1 80 443 HTTP S communication channel to WE server and D...

Page 21: ...istered TBS Partners TBS System Requirements Permanent link https cloud1 tbs biometrics com index php s q8V3hzrLyR0Mnyg Summarizes the prerequisites a site needs to offer regarding server network to h...

Reviews: