![TBK vision TBK-6004CHZ User Manaul Download Page 9](http://html1.mh-extra.com/html/tbk-vision/tbk-6004chz/tbk-6004chz_user-manaul_3837080009.webp)
8
(1).
Power Input
:
DC 12V ±10% (Recommendation 12 ±0.5V) Max 4.1W.
(2).
Video Output
:
Composite Video 1Vp-p, 75 Ohms, BNC
(3).
Audio Output
:
2Vp-p, 50 Ohms
(4).
Remote Control (6-pin Dry Contact Connector) / Key Control
:
No. Name
Function
1
Tele/
S
Zoom Tele or Up (
S
)
2 Wide/
T
Zoom Wide or Down (
T
)
3
Near/
+
Focus Near or Increase (
+
)
4
Far/
-
Focus Far or Decrease (
-
)
5
Menu
Enter or Exit Setup Menu
6 GND
Ground
It is either open under normal status (Normal Open) or close to GND under active status
(connected to GND).
CAUTION: To prevent damage on the camera, do NOT apply voltage to the dry
contact connector.
(5).
Camera Control
:
2.4K/ 4.8K/ 9.6K/ 19.2K BPS (Please refer to OSD setup MENU).
Optional: RS-232
Name Function
RD, TD
Use for RS-232 Control
GND
Pair GND for RS-232
Optional: RS-422/ RS-485
Name Function
R+, R-, T+, T-
Use For RS-422/RS-485 Control