background image

 

Figure 3.1 installation guide for connecting BC and batteries 

 
Mounting: 
Mount the battery charger on a vertical surface, using the mounting holes 

provided. Mounting hardware should be corrosion resistant. Recommend to 
use all four mounting holes. 

Connecting DC wiring for batteries: 

                         

  WARNING

         

                            All the batteries you are charging must be the same type, that is, all 

should be flooded, or all gel, or all AGM. 

 

ÿ

 

Plan the route the DC wires will follow trying to make it as short as possible. 

ÿ

 

Install the DC circuit breaker or fuses in the battery positive circuits close to the 
battery. 

ÿ

 

Fully insert each positive wire into the positive terminal on the charger. Tighten the 
connector and test that the wire is secure.   

ÿ

 

Connect the positive cable from the positive wire terminals on the charger to the 
battery fuse or breaker, which should be installed on the battery positive terminals. 
Leave the DC disconnects or breakers in the OFF position until installation is 
complete. Leaving them off helps prevent sparking when you actually make the 
connection. 

Connect AC wiring: 

Make sure the AC source circuit is disconnected by turning off the breaker feeding 

Summary of Contents for Trident

Page 1: ...ecially agreed in writing TBB Power Co Ltd a Take no warranty as to the accuracy sufficiency of suitability of any technical or other information provided in this manual or other documentation b Assum...

Page 2: ...cially agreed in writing TBB Power Co Ltd a Take no warranty as to the accuracy sufficiency of suitability of any technical or other information provided in this manual or other documentation b Assume...

Page 3: ...allation and gives some tips for the troubleshooting But it does not mention the details of the particular brands of batteries Please consult the battery manufacturer for this information Audience The...

Page 4: ...aterial List 3 2 Preparing for Installation 3 3 Installing TRIDENT 3 4 Installing Bettery Temperature Sensor 4 Operation 4 1 Dip Switch Setting 4 2 Charging Batteries 4 3 Simultaneously Recharging and...

Page 5: ...partment 4 Always interrupt the power supply when doing repair work on the unit 5 Recommend that all wiring be done by a certified technician or electrician to ensure adherence to the local and nation...

Page 6: ...mes because they produce flammable gasses and could explode 12 TRIDENT charger was designed to charge rechargeable lead acid battery GEL battery AGM battery NEVER charge other type battery or NON rech...

Page 7: ...ompartments It has AC to DC isolation a surge protector automatic multi stage charging and many other safety features which reduce potential shock and fire hazards 2 2 1 Automatic multi stage charging...

Page 8: ...ally goes into recycle charging in 14days time 2 2 5 Simultaneous Multi battery Bank charging TRIDENT battery charger has multi separate Dc positive terminals 12A has two banks 25A and 40A has three b...

Page 9: ...r DC load is voltage sensitive and did not permit high input over 14 5VDC do not connect DC load while charging if you are charging your FREEDOM batteries If you choose equalization mode do not connec...

Page 10: ...uilt in Safety TRIDENT battery charger provides the following protection features 1 Unit shutdown if there is a short circuit on output 2 Electronic protection for reversed polarity 3 Unit shutdown in...

Page 11: ...blown FLASHING Battery connection not good Wrong voltage battery connected 24V to 12V battery charger Charging ON Batteries charging constant current stage FLASHING Batteries charging constant voltage...

Page 12: ...nts as following Dry The unit is intended for use in a dry location Do not allow water or other fluids to drip or splash on it Do not mount the charger in an area subject to rain spray or splashing bi...

Page 13: ...mmended wire lengths and sizes Undersized or overly long cables may affect charging accuracy 3 2 1 DC Wiring The DC wiring must meet the following requirements Recommend sections for battery cables 12...

Page 14: ...possible Install the DC circuit breaker or fuses in the battery positive circuits close to the battery Fully insert each positive wire into the positive terminal on the charger Tighten the connector a...

Page 15: ...e sensor which is offered together with the battery charger for a proper charging of your batteries Figure 3 2 plug in the TS OPERATION 4 1 Dip Switch setting Switch 1 Default is OFF OFF battery charg...

Page 16: ...rature sensor to the battery charger and fasten the sensor head directly to the battery To assure the right charging and avoid the chance of over temp in battery it is strongly recommended the tempera...

Page 17: ...e than twice a month Always check battery fluid before and after equalization Fill batteries only with distilled water Always check the equalization switch is set back to OFF after each time s equaliz...

Page 18: ...nerator as Source Power Many generators provide output voltage that is modified sine wave MSW rather than the true sine wave TSW that your utility provides TBB does not permit the use of TRIDENT with...

Page 19: ...oltage 4 options please check 4 1 dip switch setting Equalize mode maximum output voltage 16 5VDC FREEDOM Power supply mode nominal output voltage 13 5 0 6 VDC Efficiency 0 80 PFC 95 5 3 Protection Fe...

Page 20: ...eaning TRIDENT battery charger contains solid state electronic components that require no maintenance The best care you can give the unit is to protect it from contact with liquids spray or fumes whic...

Page 21: ...icator light is flashing Battery connection not good Wrong voltage battery connected 24V to 12V battery charger Charged indicator light is flashing battery charger has no output The equalization switc...

Page 22: ...ART CHARGER Type BP1212 12V 12A BP1225 12V 25A BP1240 12V 40A The products identified above are declared in conformity with the provisions of The Council Directive of the European Union of May 3 1989...

Page 23: ...93 68 CEE This conformity is supposed by the reference to the following specifications Standard NF EN 55014 1 2000 A1 2001 A2 2002 generic Standard emission Standard NF EN 55014 2 1997 A1 2001 generic...