TBB power MPPT User Manual Download Page 10

                                 

    MPPT charge controller User Manual 

                              

 

2.2.2 Connection compartment 

External interface terminal as shown in Figure 2-2. 

 

Figure 2-2 Connection terminals   

Table 2-3 Connection terminal introduction 

Silk-screen

 

Definition

 

PV 

Connection terminal for PV array Positive 

Connection terminal for PV array Negative 

BAT 

Connection terminal for Battery Positive 

Connection terminal for Battery Negative 

EPO 

EPO contacts, defined for remote on/off. 

NC 

Output dry contacts. 

NO 

RS485 

Connection terminal for RS485 communication. 

Temp. Sensor 

Connection terminal for battery temperature sensor. 

Table 2-4 Pin definition of Temp. Sensor 

Pin 

Definition 

Pin1 

Battery Positive 

Pin2 

Battery Negative 

Pin3 

Temperature sensor 

Pin4 

Battery Negative 

Table 2-5 Pin definition of RS485 communication port 

Pin 

Definition 

Pin1 

 

Pin2 

 

Pin3 

RS485_A 

Pin4 

 

Pin5 

 

Pin6 

RS485_B 

Pin7 

 

Pin8 

 

Summary of Contents for MPPT

Page 1: ......

Page 2: ...MPPT charge controller User Manual...

Page 3: ...MPPT charge controller User Manual WARNING HIGH VOLTAGE INSIDE CAUTION THE DC FUSE MUST HAVE BEENTURNED OFF BEFORE SERVICING MADE IN CHINA...

Page 4: ...cts taking no responsibility for direct or indirect loss due to equipment failure About this Manual This manual describes our product features and provides procedure of installations This manual is fo...

Page 5: ...3 Function 5 2 3 1 Maximum Power Point Tracking 5 2 3 2 Battery charging control 5 2 3 3 Auxiliary Output 6 2 3 4 TBB premium II charging algorithm 6 2 3 5 Comprehensive Protection 7 2 3 6 Equalizati...

Page 6: ...wer OFF 16 4 4 Setup Wizard 16 5 Operation 17 5 1 Menu introduction 17 5 2 Initial interface 18 5 3 Real time information interface 18 5 4 Information query interface 18 5 5 5 5 P Pa ar ra am me et te...

Page 7: ...hock make sure all cables selected with right gauge and being connected well Smaller diameter and broken cable are not allowed to use Please do not put any inflammable goods near to charge controller...

Page 8: ...fered as well Meantime version for Lead Carbon battery and lithium ion battery were available upon request Maximum MPPT efficiency up to 99 9 Maximum efficiency up to 98 2 Excellent performance at sun...

Page 9: ...n 2 seconds to scroll the page up Display the next page Decrease the value of the selected item Press the button for more than 2 seconds to scroll the page down Enter into this menu displaying the nex...

Page 10: ...minal for Battery Positive Connection terminal for Battery Negative EPO EPO contacts defined for remote on off NC Output dry contacts C NO RS485 Connection terminal for RS485 communication Temp Sensor...

Page 11: ...n attempt to find the maximum power point of the array no matter how the weather changes With MPPT we can maximize the usage of the PV array increasing the system efficiency by maximum 30 2 3 2 Batter...

Page 12: ...harging and Recycle charging program guarantee your battery could get proper maintenance in case of long time connected Battrry Voltage Charging Current Soft Start Bulk Absorption Float Recycle Icc 11...

Page 13: ...above commonly encountered battery categories of which you can set through the LCD and control button 2 3 5 Comprehensive Protection The equipment is being protected against many failures through har...

Page 14: ...ended to read this section carefully before you start the EQ charging and Don t leave battery unattended while performing desulfuration Always check if your battery supplier recommended EQ charging On...

Page 15: ...uring equalization The voltage applied to the battery during equalization may be above the safe levels for some loads Frequency Maximum once a month for heavily used battery you may wish to equalize y...

Page 16: ...ler 1 User manual 1 3Pin connector 1 2Pin connector 1 3 2 Select installation location 3 2 1 Requirement The protection level of charger is IP31 which can only be installed indoors During the operatio...

Page 17: ...tallation Please choose a flat surface and with 4xM5 supplied to install following Figure 3 2 Install the SP as close to the batteries as possible reducing the voltage drop on cable for the better per...

Page 18: ...exceed 20A when PV polarity is reversed The Voc or Vmpp of solar panel was rated at 25 with normal weather condition Along with temperature reduced the Voc Vmpp of solar array will increase Please co...

Page 19: ...100V 2 The current requirement is greater than 40A SP100 20 1 The voltage requirement is greater than 100V 2 The current requirement is greater than 32A SP50 40 1 The voltage requirement is greater th...

Page 20: ...moving wiring cover plate follows the arrow then you will see as Figure 3 3 b Table 3 5 toggle switch definition on cover plate Pin Definition Pin1 NA Pin2 NA Pin3 NA Pin4 OFF Low power consumption mo...

Page 21: ...Array Battery BAT BAT Figure 3 4 Wiring diagram of Solar Mate Step2 Please select the appropriate wire according to section 3 4 3 Step3 Please connect BAT to battery negative and connect BAT to batte...

Page 22: ...by step according to the setup wizard Step 4 Observe the LED light to make sure the MPPT charger is running normally refer to Table 2 2 LED directive function 4 3 Power OFF After the MPPT charger is p...

Page 23: ...own Down Down Down Up Up Up Up Down CANCEL Up System Info ENTER CANCEL Up Down User Control Up Down ENTER CANCEL ENTER CANCEL 0 error 0 warning Para_Battery Change Password Model Serial Number Softwar...

Page 24: ...10 13 26 Charger_Standby U_PV 103 4V P_Output 0W U_BAT 53 4V I_CHG 0 0A 5 4 Information query interface Press the in the standby interface to enter the 1st level menu Press the button on the first le...

Page 25: ...PPT Warn 06 T_BatExt_OT History Record Enter to see history record information Press to scroll through the pages the secondary menu when the event occur Press the to enter the third level menu to disp...

Page 26: ...o the begin and set again A failure Setting prompt appears Go to the next setting item Yes No Change the parameters Yes No Press the a confirmation prompt appears press the to set the default paramete...

Page 27: ...nput dry contacts of the Kinergier Pro Select1 short connection at fault alarm Silent_Mode_EN 0 Disable 1 Enable Default setting 0 Disable Silent mode setting Force_Charger 0 Disable 1 BAT_Level_12 2...

Page 28: ...hanged when changing the battery type users can reset it with their requirements U_Float_CHG Please refer to Table 5 1 Default setting 13 7V The float charging voltage of battery Note This value will...

Page 29: ...fault setting 55 The over temperature warning of BAT setting In EQ Setting there are the following Setting options Display Setting range Description EQ_Command 0 Off 1 On Default setting 0 Off Equaliz...

Page 30: ...tting 15 2V Setting range 14 0 15 5V Default setting 13 5V Setting range 13 0 14 0V 0 15C OPzS Default setting 14 7V Setting range 14 0 15 5V Default setting 13 4V Setting range 13 0 14 0V 0 15C BMS G...

Page 31: ...on Change battery voltage of the charger or change battery configuration If it happens frequently please contact your dealer 03 U_Bat_OV_HD 04 Buck_Short Cut Battery short circuit Check battery wiring...

Page 32: ...U_BAT_LV Battery voltage is too low Please check the battery voltage Wait the charger charging until the battery voltage normally 03 Cur_Limit Charging current over range Check whether the maximum cha...

Page 33: ...56 4VDC Charge voltage float Default setting 13 7VDC 27 4VDC 54 8VDC Charging algorithm TBB II multiple stages Temperature compensation Default setting 3mV cell Others Display LED LCD Communication p...

Page 34: ...MPPT charge controller User Manual 2...

Page 35: ...MPPT charge controller User Manual 2...

Page 36: ...MPPT charge controller User Manual 3...

Reviews: