WARNING: Cancer and Reproductive Harm - www.P65Warnings.ca.gov
Form-Flex
®
Single Flex Coupling
Type HH & FH All Sizes
Installation Instructions
P-5004-TBW
FORM 1174
Form 1174
Single Flex Coupling
Installation and Maintenance Instructions
TYPE HH & FH ALL SIZES
(HH)
Fig. 1
Fig. 2
(FH)
PARTS LIST
1. NUT (8)
2. WASHER (8)
3. FLEX ELEMENT (1)
4. BOLT (8)
5. HUB (2)
PARTS LIST
1. ADAPTER (1)
2. NUT (8)
3. WASHER (8)
4. FLEX ELEMENT (1)
5. BOLT (8)
6. HUB (1)
Proper care in installing and aligning will permit couplings to operate to full capacity, compensate for misalignment, and
provide very good service life.
1. Inspect shafts and hubs bores and make sure they are free from burrs. Check for the proper fit of the keys to the shafts
and hubs.
2. Fit the couplings hub(s) so that the shaft end(s) is/are flush with the machined face of the flange. If the hub is bored for
interference fit, the hubs should be heated then quickly positioned on the shaft.
Do Not
spot heat or heat above 300°F
as it may cause distortion.
3. Move the equipment to be connected into position. Set the gap to the required “D” dimension. See Fig. 1 or 2.
Form-Flex
®