TB Wood's Form-Flex HH Series Installation Instructions Download Page 1

 

WARNING: Cancer and Reproductive Harm - www.P65Warnings.ca.gov

Form-Flex

® 

Single Flex Coupling 

Type HH & FH All Sizes 

Installation Instructions

P-5004-TBW

FORM 1174

Form 1174

Single Flex Coupling

Installation and Maintenance Instructions

TYPE HH & FH ALL SIZES

(HH)

Fig. 1

Fig. 2

(FH)

    PARTS LIST

1. NUT (8)

2. WASHER (8)

3. FLEX ELEMENT (1)

4. BOLT (8)

5. HUB (2)

    PARTS LIST

1. ADAPTER (1)

2. NUT (8)

3. WASHER (8)

4. FLEX ELEMENT (1)

5. BOLT (8)

6. HUB (1)

Proper care in installing and aligning will permit couplings to operate to full capacity, compensate for misalignment, and 

provide very good service life.

1. Inspect shafts and hubs bores and make sure they are free from burrs. Check for the proper fit of the keys to the shafts 

    and hubs.

2. Fit the couplings hub(s) so that the shaft end(s) is/are flush with the machined face of the flange. If the hub is bored for 

    interference fit, the hubs should be heated then quickly positioned on the shaft. 

Do Not

 spot heat or heat above 300°F 

    as it may cause distortion.

3. Move the equipment to be connected into position. Set the gap to the required “D” dimension. See Fig. 1 or 2.