2
Models C708 & C716
To the Installer
080912
Air Cooled Units
DO NOT obstruct air intake and discharge openings:
Model C708:
Requires a minimum of 6” (152 mm) of
clearance on both sides and 0” in the rear of the
unit.
Model C716:
Requires a minimum of 3” (76 mm) of
clearance on all sides. Install the deflector provided
to prevent recirculation of warm air.
This will allow for adequate air flow across the
condensers. Failure to allow adequate clearance can
reduce the refrigeration capacity of the freezers and
possibly cause permanent damage to the
compressors.
Water Connections
(Water Cooled Units Only)
An adequate cold water supply must be provided
with a hand shut-off valve. On the underside of the
base pan or on the right side, two 3/8” I.P.S. water
connections for inlet and outlet are provided for easy
hook-up. 1/2” inside diameter water lines should be
connected to the machine. (Flexible lines are
recommended, if local codes permit.) Depending on
local water conditions, it may be advisable to install
a water strainer to prevent foreign substances from
clogging the automatic water valve. There will be
only one water “in” and one water “out” connection.
DO NOT install a hand shut-off valve on the water
“out” line! Water should always flow in this order:
first, through the automatic water valve; second,
through the condenser; and third, through the outlet
fitting to an
open trap drain.
A back flow prevention device is
required on the incoming water connection side.
Please refer to the applicable National, State, and
local codes for determining the proper configuration.
Electrical Connections
In the United States, this equipment is intended to
be installed in accordance with the National
Electrical Code (NEC), ANSI/NFPA 70-1987. The
purpose of the NEC code is the practical
safeguarding of persons and property from hazards
arising from the use of electricity. This code contains
provisions considered necessary for safety. In all
other areas of the world, equipment should be
installed in accordance with the existing local codes.
Please contact your local authorities.
FOLLOW YOUR LOCAL ELECTRICAL CODES!
Each freezer requires one power supply for each
data label. Check the data label on the freezer for
fuse, circuit ampacity and electrical specifications.
Refer to the wiring diagram provided inside of the
electrical box, for proper power connections.
CAUTION: THIS EQUIPMENT MUST BE
PROPERLY GROUNDED! FAILURE TO DO SO
CAN RESULT IN SEVERE PERSONAL INJURY
FROM ELECTRICAL SHOCK!
This unit is provided with an equipotential
grounding lug that is to be properly attached to the
rear of the frame by the authorized installer. The
installation location is marked by the equipotential
bonding symbol (5021 of IEC 60417-1) on both the
removable panel and the equipments frame.
S
Stationary appliances which are not
equipped with a power cord and a plug or
another device to disconnect the appliance
from the power source must have an all-pole
disconnecting device with a contact gap of
at least 3mm installed in the external
installation.
S
Appliances that are permanently connected
to fixed wiring and for which leakage
currents may exceed 10 mA, particularly
when disconnected or not used for long
periods, or during initial installation, shall
have protective devices such as a GFI, to
Summary of Contents for Wawa C708
Page 1: ...Models C708 C716 Heat Treatment Soft Serve Freezer Operating Instructions 059061 M 6 17 08...
Page 71: ...Model C708 057010 27 Rev 2 08...
Page 72: ...Model C708 057010 27 Inset Rev 2 08...
Page 73: ...Model C708 057010 33 Rev 2 08...
Page 74: ...Model C708 057010 40 Rev 2 08...
Page 75: ...Model C708 057010 58 Rev 2 08...
Page 76: ...Model C716 059900 27 Rev 2 08...
Page 77: ...Model C716 059900 27 Inset Rev 2 08...
Page 78: ...Model C716 059900 33 Rev 2 08...
Page 79: ...Model C716 059900 40 Rev 2 08...
Page 80: ...Model C716 059900 58 Rev 2 08...