Important: Operator Checklist
Section 8
Troubleshooting Guide
PROBLEM
PROBABLE CAUSE
REMEDY
PAGE
REF.
1. Soft lock message
appears on display.
a. More than 24 hours since
the last HEAT cycle.
a. The freezer must go
through a HEAT cycle
every 24 hours. The
freezer must now be
disassembled and brush
cleaned or placed in a
heat cycle.
20
b. The power switch is in the
OFF position.
b. The power switch must be
in the ON position. The
freezer must now be
disassembled and brush
cleaned or placed in a
heat cycle.
21
c. The freezer was not in the
AUTO or STANDBY mode
when the heat cycle was
programmed to start.
c. The freezer must be in the
AUTO or STANDBY
mode. The freezer must
now be disassembled and
brush cleaned or placed in
a heat cycle.
21
d. Mix out or mix low
condition.
d. The level of mix in the mix
hopper must be above the
mix low probe. The
freezer must now be
disassembled and brush
cleaned or placed in a
heat cycle.
21
e. The agitator is not
installed.
e. The agitator must be
cleaned and installed
before starting the HEAT
cycle. The freezer must
now be disassembled and
brush cleaned or placed in
a heat cycle.
40
f. There was a power failure.
f. Check fault messages and
product temperature.
Disassemble and brush
clean, or initiate a heat
treatment cycle.
26
Summary of Contents for Wawa C708
Page 1: ...Models C708 C716 Heat Treatment Soft Serve Freezer Operating Instructions 059061 M 6 17 08...
Page 71: ...Model C708 057010 27 Rev 2 08...
Page 72: ...Model C708 057010 27 Inset Rev 2 08...
Page 73: ...Model C708 057010 33 Rev 2 08...
Page 74: ...Model C708 057010 40 Rev 2 08...
Page 75: ...Model C708 057010 58 Rev 2 08...
Page 76: ...Model C716 059900 27 Rev 2 08...
Page 77: ...Model C716 059900 27 Inset Rev 2 08...
Page 78: ...Model C716 059900 33 Rev 2 08...
Page 79: ...Model C716 059900 40 Rev 2 08...
Page 80: ...Model C716 059900 58 Rev 2 08...