Model C709
057010-27
06/14
Taylor Company
2014 Carrier Commercial Refrigeration, Inc.
c
JP6
NO
JP7
JUMPER INSTALLED DISABLES RESET.
NO
RTCK
RESERVED (DO NOT USE)
NO
DBGEN
RESERVED (DO NOT USE)
NO
W1
RESERVED (DO NOT USE)
NO
JUMPER INSTALLED-FORCE BRUSH CLEAN STATUS.
JUMPER INSTALLED-OPEN ALL SOLENOIDS.
RESERVED (DO NOT USE)
W6
JUMPER INSTALLED-REDUCED MIX LOW SENSITIVITY.
NO
W7
JUMPER INSTALLED-REDUCED MIX OUT SENSITIVITY.
NO
PINS 1 & 2
JUMPER INSTALLED-ENABLES 59
F HOPPER
TEMPERATURE CHECK.
PINS 7 & 8
JUMPER INSTALLED W/SWITCH-SELF SERVE
APPLICATION ONLY. LOCKS OUT TOUCH
PANEL. NEW SWITCH ACTS AS THE ON/OFF
ABILITY TO ACTIVATE THE TOUCH PANEL.
NO
B
SOFT SERVE
PERSONALITY
BOARD
0-12 AMP BEATER MOTOR AMPERAGE RANGE
YES
BROWN
J2
J3
GND
+5V
J5
1 2 3 4 5 6
J6
1
2
3
4
5
6
L1
7
J7
1
2
3
4
5
6
7
3
1
5
J8
J9
J12
J11
1
2
3
4
5
6
7
8
J10
1
2
3
4
5
6
7
8
9
10
B A
J14
INTFC PCB A.
WITH SOFT SERVE
PERSONALITY PCB A.
7 8
J13
RED
WHT/RED
ON
OFF
BARREL
LIQUID
SOLENOID
HOPPER
LIQUID
SOLENOID
WHT/O
RN
14
13
BEATER
INTERLOCK
RELAY
4
12
8
1
9
5
WHT
M
AGITATOR
MOTOR
SEE
DETAIL
WHT
24 VAC
CO
M
BLU/WHT
WHT
BLK/BLU
HOPPER
HOT GAS
SOLENOID
BARREL
HOT GAS
SOLENOID
BLU
BLU
BEATER
MOTOR
INTERLOCK
N.O. SWITCH
USER
INTERFACE
BOARD
0
1
3
4
2
7
8
6
0
1
3
4
2
7
8
6
HOPPER
HOT GAS
SOLENOID
RELAY
BARREL
HOT GAS
SOLENOID
RELAY
- 8 LEDS
- LCD SCREEN
- 9 KEYS
- BEEPER
BLK
BLK
TAN
WHT
BLK
GRA/BLK
GRA
BLU/WHT
BLU/WHT
BLK
YEL/BLK
BLK
GRA
BLU
BLU/WHT
BLU/WHT
BLK
BRN/WHT
BRN/WHT
BRN/WHT
BRN/WHT
BRN/WHT
RED
1
2
3
4
T8
T1
T7
T4
T5
BLACK
BLUE
BLACK
T1
CP
T2
L1
CP
L2
BEATER MOTOR
CONTACTOR
LEESON BEATER MOTOR WIRING
STEPS:
1) DISCONNECT WIRE T7 FROM TERMINAL 3
2) SPLICE BLUE WIRE AS SHOWN
1
2
4
6
BLACK
BLUE
BLACK
T1
CP
T2
L1
CP
L2
BEATER MOTOR
CONTACTOR
A.O. SMITH BEATER MOTOR WIRING
STEPS:
1) REMOVE BROWN JUMPER FROM BETWEEN TERMINAL #1 TO TERMINAL #5
2) MOVE BLUE INTERNAL (FROM MOTOR MAIN WINDING)
FROM TERMINAL #5 TO TERMINAL #1.
NOTE: FOR CCWLE - BLUE INTERNAL ON #1, YELLOW INTERNAL ON #6
BLUE INTERNAL
3
5
ORANGE INTERNAL
RED INTERNAL
YELLOW INTERNAL
BLACK INTERNAL
BLUE
BLUE
T3
L3
USE T3 AND L3 WHEN
CP CONTACTS ARE NOT AVAILABLE
T3
L3
USE T3 AND L3 WHEN
CP CONTACTS ARE NOT AVAILABLE
1
2
5
4
S
R
LINE
RELAY
START CAPACITOR
C
INTERNAL OVERLOAD
RUN CAPACITOR
SCHEMATIC WIRING DIAGRAM - CSR
1
2
5
4
C
S
R
LINE
RELAY
RUN
CAP.
START CAP.
COMPRESSOR
TERMINAL
COVER
ABOVE ELECTRICAL DIAGRAM SHOWS WIRIN
G NECESSARY
TO HOOK UP A COMPRESSOR USING A STAR
T AND RUN
CAPACITOR (CSR) WITH A RELAY.
WHITE
BROWN
BLACK
BROWN
052396-1
EQUIPMENT
GROUND
BLEED RESISTOR
WHITE(120 VOLTS)
BLACK(230 VOLTS)
BLACK
BLUE
CLR (+5v)
BLK (GRD)
BLU
BRN/WHT
HOPPER
GROUND
BLUE
GRA/WHT
WHT/BRN
BLK
LIV
SOLENOID
BLK
M
L2
L1
T1
T2
AIR COOLED ONLY
COMPRESSOR
CONTACTOR
RED
WHT
M
BLU/WHT
BLUE
AGITATOR MOTOR
DETAIL
SE
BLUE
WHT
RED
SNUBBER
WHT
ORN
TAN
BLK
#3
#1
208
*C708*
NO
NC
DRAW
SWITCH
C0M
PANEL
JACK
ADDITIONAL DRAW SWITCH
FOR FLAVORBURST
BLACK
BLUE
BLACK
T1
CP
T2
L1
CP
L2
BEATER MOTOR
CONTACTOR
GE/RBC BEATER MOTOR WIRING
NOTE: FOR CCWLE - BLUE INTERNAL ON #1,YELLOW INTERNAL ON #2
BLUE
T3
L3
USE T3 AND L3 WHEN CP
CO
NTACTS ARE NO
T AVAILABLE
J12 O
R PURPLE INTERNAL
T1 O
R BLUE INTERNAL
T8 O
R RED INTERNAL
J9 O
R BLACK INTERNAL
A
1
4
5
T4 O
R YELLO
W INTERNAL
2
FIG. 3
A
LEFT SYRUP HEATER
THERMOSTAT
140° OPEN
100° CLOSE
WHT
WHT
O.T.
RIGHT SYRUP HEATER
THERMOSTAT
140° OPEN
100° CLOSE
WHT
WHT
O.T.
BLK
BLK
WHT
GRN
WHT
C
NO
208-230 VAC
012626
WHT
OPTIONAL HEATED SYRUP RAIL
WHT
M
MIX
PUMP
MOTOR
BLK
BLU
2
3
4
RED
START
RELAY
ORN
PUR
YEL
WHT
FIG 2
ALTERNATE MIX PUMP MOTOR WIRING
NOTE:
1. STATIC ELECTRICITY MAY CAUSE
DAMAGE TO SOLID STATE COMPONENTS.
ELIMINATE STATIC ELECTRICITY BY
TOUCHING GROUNDED UNIT BEFORE
HANDLING SOLID STATE COMPONENTS.
2. RED WIRE ON RIBBON CABLES MUST BE
CONNECTED TO PIN 1 AT EACH END.
EXTERNAL
GROUND
L2
GROUND FRAME SECURELY
L1
TERMINAL BLOCK
BRN/WHT
INTERFACE BOARD
POWER TRANSFORMER
BLK
ORN
RED
BLU
16V
L2
LOAD
LINE
L1
L1
L2
240V
WHT
NOT
CONNECTED
WHT
WHT
GRN/YEL
GRN/YEL
BLK
GRN/YEL
BRN/WHT
POWER
SWITCH
DPDT
BLK
ON
OFF
RED
BLU
GRN/YEL
BLK
BLK
BLK
BLK
BLK
HOPPER
BARREL
--THERMISTOR PROBES--
BLK
BLK
YEL
YEL
RIBBON
CABLE
BLU
RED
MIX
LOW
PROBE
MIX
OUT
PROBE
PRP/WHT
PRP/WHT
GRN/YEL
GRA/BLK
RED/BLK
NO
NC
BLK
DRAW
SWITCH
COM
RIBBON CABLE
RED
BLU
RED
BLU
RED
BLU
RIBBON CABLE
WHT
WHT
WHT/ORN
RED
COMPRESSOR
CONTACTOR
COIL
BLK
M
MIX
PUMP
MOTOR
(SEE FIG 2)
BLK
OVERLOAD
SWITCH
2
3
4
WHT
RED
START
RELAY
BEATER
MOTOR
STARTER
COIL
WHT
ORN
WHT/ORN
BLK
BLK
BLK
BEATER
MOTOR
OVERLOAD
SWITCH
BLK
BLK
COMPRESSOR
HIGH PRESSURE
LIMIT SWITCH
BLK
BLK
BLK
ORN/WHT
PURPLE
YEL
BARREL
SUCTION
SOLENOID
ORN
WHT
GRN/YEL
GRN/YEL
BLK
SV CABLE
SV CABLE
BLK
BLK
BLK
BLK
BLK
BLK
BLK
BLK
BLK
BLK
BRN/WHT
M
T2
SOFT SERVE
COMPRESSOR
L2
L1
T1
CONDENSER
FAN MOTOR
M
BLK
BLK
BLUE
BLK
BEATER MOTOR
STARTER
BEATER MOTOR
STARTER
BLK
SOFT SERVE
BEATER MOTOR
BLK
BLK
BLK
BLK
CLR
ONE SIDE OF A
TWO WIRE CORD
FUSE
15A
4
5
EMI FILTER
UVC4
BOARD
FUNCTION
JUMPER
INSTALLED
INITIALLY
JP1
PINS 1 AND 2
JUMPER INSTALLED- BARREL AND HOPPER
TEMPERATURES ARE CHECKED DURING
AUTO/STANDBY. UNIT IS LOCKED OUT IF
EITHER BARREL OR HOPPER IS TOO WARM FOR
A PERIOD OF TIME. LOCKOUT OCCURS WHEN
BARREL OR HOPPER IS ABOVE 45
F (7
C)
FOR MORE THAN ONE HOUR OR ABOVE 41
F
(5
C) FOR MORE THAN FOUR HOURS.
YES
NO JUMPER INSTALLED-NO LOCKOUT DURING
AUTO/STANDBY IF BARREL OR HOPPER IS TOO
WARM FOR A PERIOD OF TIME.
PINS 3 AND 4
RESERVED (DO NOT USE)
NO
JP2
PINS 1 AND 2
DOMESTIC CONFIGURATION-JUMPER INSTALLED.
HOPPER TEMPERATURE NOT DISPLAYED ON
SCREEN/HEAT SYMBOL KEYS ONLY ACTIVE
WHEN A LOCKOUT CONDITION HAS OCCURRED/
STANDBY KEYS DISABLED.
YES
INTERNATIONAL CONFIGURATION-NO JUMPER
INSTALLED. HOPPER TEMPERATURES
DISPLAYED ON SCREEN/MANUAL HEAT CYCLE
START BY SELECTING HEAT SYMBOL/STANDBY
KEYS FUNCTIONAL.
JP3
RESERVED (DO NOT USE)
NO
JP4
RESERVED (DO NOT USE)
NO
JP5
RESERVED (DO NOT USE)
NO
RESERVED (DO NOT USE)
INTERFACE
BOARD
FUNCTION
JUMPER
INSTALLED
INITIALLY
W2
NO
W3
RESERVED (DO NOT USE)
NO
W4
NO
W5
NO
J10
YES
NO
A
SOFT SERVE
PERSONALITY
BOARD
0-6 AMP BEATER MOTOR AMPERAGE RANGE
BLK
BLK
BLK
M
WHT
PANEL SPINNER OPTION
SEE FIG. 1
BRN/WHT
M
BLK
BLK
BLK
BLK
BLK
WHT
LINE
LOAD
LINE FILTER
SPINNER MOTOR WIRING
FIG. # 1
LINE
GRN/YEL
WHT
WHT
WHT
BLK
BLK
BLK
BLU/WHT
BLU
BLU
BLU
LOW PRESSURE
FAN SWITCH
WHT/GRA
BLU
BLU
JUMPER SETTINGS
WHT
WHT
L2
(SEE FIG 3)
J1
J3
GRD
+5V
J2
J11
J10
J7
J1
1
2
UNIVERSAL CONTROL PCB A.
BLK
CLR
J9
J12
SHIELD CUT
NO CONNECTION
THIS END
J17
J15
J8
5
4
6
2
1
3
J13
J4
J16
3
4
2
7
8
6
1
5
RED
GRN
WHT
BLK
CABLE
RIBBON CABLE
RIBBON CABLE
BLK
YEL
SELF SERVICE
ENABLE
(OPTIONAL)
DISABLE
ENABLE
EQUIPOTENTIAL
GROUND
BLK
BLK
208/230 VOLTS, 60HZ
(DOMESTIC)
L1
L2
208/230 VOLTS, 60HZ
(INTERNATIONAL)
L1
L2 OR N
WIRE COLORS - BASED ON INCOMING POWER
FIG. 4
BLK
BLK
GRN/
YEL
GRN/
YEL
GRN/
YEL
GRN/
YEL
G
R
N
/
YEL
G
R
N
/
YEL
(SEE FIG.4)