To the Installer

101027

Water Connections

(Water Cooled Units Only)

An adequate cold water supply must be provided with

a hand shut--off valve. On the underside rear of the

base pan, two 3/8” I.P.S. water connections for inlet

and outlet have been provided for easy hook--up. 1/2”

inside diameter water lines should be connected to the

machine. (Flexible lines are recommended, if local

codes permit.) Depending on local water conditions, it

may be advisable to install a water strainer to prevent

foreign substances from clogging the automatic water

valve. There will be only one water “in” and one water

“out” connection. DO NOT install a hand shut--off valve

on the water “out” line! Water should always flow in this

order: first, through the automatic water valve; second,

through the condenser; and third, through the outlet

fitting to an

open trap drain.

A back flow prevention device is required

on the incoming water connection side.

Please

refer to the applicable National, State, and local codes

for determining the proper configuration.

Electrical Connections

In the United States, this equipment is intended to be

installed in accordance with the National Electrical

Code (NEC), ANSI/NFPA 70-1987. The purpose of the

NEC code is the practical safeguarding of persons and

property from hazards arising from the use of

electricity. This code contains provisions considered

necessary for safety. In all other areas of the world,

equipment should be installed in accordance with the

existing local codes. Please contact your local

authorities.

FOLLOW YOUR LOCAL ELECTRICAL CODES!

Each unit requires one power supply for each data

label on the unit. Check the data label(s) on the freezer

for branch circuit overcurrent protection or fuse, circuit

ampacity, and other electrical specifications. Refer to

the wiring diagram provided inside of the electrical box

for proper power connections.

CAUTION: THIS EQUIPMENT MUST BE

PROPERLY GROUNDED! FAILURE TO DO SO

CAN RESULT IN SEVERE PERSONAL INJURY

FROM ELECTRICAL SHOCK!

DO NOT operate this freezer with larger fuses

than specified on the unit data label. Failure to follow

this instruction may result in electrocution or damage

to the machine.

This unit is provided with an equipotential

grounding lug that is to be properly attached to the rear

of the frame by the authorized installer. The installation

location is marked by the equipotential bonding

symbol (5021 of IEC 60417-1) on both the removable

panel and the equipments frame.

Stationary appliances which are not equipped

with a power cord and a plug or another device to

disconnect the appliance from the power source must

have an all-pole disconnecting device with a contact

gap of at least 3mm installed in the external

installation.

Appliances that are permanently connected to

fixed wiring and for which leakage currents may

exceed 10 mA, particularly when disconnected or not

used for long periods, or during initial installation, shall

have protective devices such as a GFI, to protect

against the leakage of current, installed by the

authorized personnel to the local codes.

Summary of Contents for C706

Page 1: ...Model C706 Soft Serve Freezer Original Operating Instructions 056436 M February 2003 Original Publication Updated May 2011...

Page 2: ...the data label Model Number Serial Number Electrical Specs Voltage Cycle Phase Maximum Fuse Size A Minimum Wire Ampacity A E February 2003 Taylor All rights reserved 056436 M The word Taylor and the...

Page 3: ...Simplified 9 Accessories 10 Section 5 Important To the Operator 11 Symbol Definitions 12 Power Switch 12 Indicator Lights 12 MIX REF Key 12 STANDBY Key 12 WASH Key 13 AUTO Key 13 Pump Key 13 Beater M...

Page 4: ...s Replacement Schedule 34 Section 10 Parts List 35 Wiring Diagram 43 Note Continuing research results in steady improvements therefore information in this manual is subject to change without notice No...

Page 5: ...performed by an authorized Taylor Service Technician This unit has many sharp edges that can cause severe injuries Site Preparation Review the area the unit is to be installed in before uncrating the...

Page 6: ...ld be installed in accordance with the existing local codes Please contact your local authorities FOLLOW YOUR LOCAL ELECTRICAL CODES Each unit requires one power supply for each data label on the unit...

Page 7: ...t Taylor proudly uses only earth friendly HFC refrigerants The HFC refrigerant used in this unit is R404A This refrigerant is generally considered non toxic and non flammable with an Ozone Depleting P...

Page 8: ...e disposed as unsorted municipal waste The user is responsible for returning the product to the appropriate collection facility as specified by your local code For additional information regarding app...

Page 9: ...emovable panel and the equipments frame DO NOT use a water jet to clean or rinse the freezer Failure to follow these instructions may result in serious electrical shock S DO NOT operate the freezer un...

Page 10: ...ve gloves must be worn and the mounting holes must NOT be used to lift or hold the dispenser Failure to follow this instruction can result in personal injury to fingers or equipment damage Cleaning an...

Page 11: ...NEL SIDE LEFT 066722 SP2 5 STUD NOSE CONE 055987 6 SHIELD SPLASH 049203 7 TRAY DRIP 056858 8 PANEL FRONT LOWER 058942 9 PANEL A FRONT UPPER X58950 ITEM DESCRIPTION PART NO 10 PANEL A SIDE RIGHT STD UN...

Page 12: ...0 015872 5 PIN HANDLE S S 055819 6 PLUG PRIME 028805 7 O RING 3 8 OD X 070W 016137 8 VALVE A DRAW X56072 9 O RING 7 8 OD X 103 W 014402 ITEM DESCRIPTION PART NO 10 NUT STUD BLACK 3 25 LONG 058765 11 N...

Page 13: ...STON 053526 4 O RING 2 1 8 OD RED 020051 5 CAP VALVE 056874 12 6 GASKET SIMPLIFIED PUMP VALVE 053527 7 ADAPTOR MIX INLET 054825 8 O RING 11 16 OD RED 016132 ITEM DESCRIPTION PART NO 9 PIN COTTER 04473...

Page 14: ...DRAW VALVE 1 ODX2 013073 5 BRUSH MIX PUMP BODY 3 X7 023316 6 SANITIZER STERA SHEEN JAR 010425 CS SANITIZER STERA SHEEN 100 2 OZ PACKETS 055492 ITEM DESCRIPTION PART NO 7 PAIL MIX 10 QT 013163 8 BRUSH...

Page 15: ...IPTION 1 MIX LOW INDICATOR LIGHT 2 MIX OUT INDICATOR LIGHT 3 MIX REFRIGERATION KEY 4 STANDBY KEY 5 WASH KEY 6 AUTO KEY ITEM DESCRIPTION 7 PUMP KEY 8 RESET BUTTON BEATER MOTOR 9 RESET BUTTON PUMP 10 PO...

Page 16: ...tion system is operating The MIX REF function cannot be cancelled unless the AUTO or STANDBY modes are cancelled first STANDBY Key The Separate Hopper Refrigeration System SHR and the Cylinder Tempera...

Page 17: ...ress the AUTO key to cancel the cycle Turn the power switch to the OFF position Press the reset button firmly Do not use metal objects to press the reset button Failure to follow this instruction may...

Page 18: ...ery time the draw handle is raised new mixand air from the hopper flow into the freezing cylinder This keeps the freezing cylinder properly loaded and maintains overrun 2 Long No Sale Periods During l...

Page 19: ...ml Check the water daily Place the heater switch in the ON position The heating process will take approximately 1 1 4 hours Prepare a pail of an approved 100 PPM sanitizing solu tion examples Kay 5R...

Page 20: ...e must fit securely over the pin to prevent costly damage Figure 8 Holding the rear blade on the beater slide it halfway in to the freezing cylinder Install the front scraper blade over the front hold...

Page 21: ...e is at the bottom Figure 14 Step 6 Install the adjustable draw handle Slide the fork over the bar in the slot of the draw valve Secure with pivot pin Figure 15 Note This unit features an adjustable d...

Page 22: ...condition for the pump and entire machine to operate properly The o rings and gasket cannot properly serve their intended function if nicks cuts or holes in the material are present Replace any defect...

Page 23: ...ith a paper thin layer of lubricant Figure 22 Step 7 Insert the piston into the bottom of the pump cylinder Figure 23 Step 8 Insert the mix inlet assembly into the pump cylinder Figure 24 The drive ho...

Page 24: ...f the retaining pin should be facing UP with the pump correctly installed Step 10 Assemble the feed tube assembly Slide the valve o ring into the groove of the feed tube Figure 26 Step 11 Install one...

Page 25: ...PPM sanitizing solution examples 2 1 2 gal 9 5 liters of Kay 5R or 2 gal 7 6 liters of Stera SheenR USE WARM WA TER AND FOLLOW THE MANUFACTURER S SPECIFICATIONS Step 2 Pour the sanitizing solution ov...

Page 26: ...place by slipping the pump clip over the collar of the pump making sure the clip fits into the grooves in the collar Figure 32 Step 5 Place the power switch in the ON position Figure 33 Step 6 Press t...

Page 27: ...ese instructions Step 10 Lubricate the mix feed tube o rings located on the end of the tube with the small hole on the side Stand the mix feed tube in the corner of the mix hopper Place the locking cl...

Page 28: ...he mix pump Secure with locking clip Figure 40 Step 4 Press the AUTO key When the unit cycles off the product will be at serving viscosity Figure 41 Step 5 Fill the hopper with fresh mix As the mix le...

Page 29: ...rinse water is flowing from the prime plug opening in the bottom of the freezer door lower the draw handle Drain all the rinse water from the freezing cylinder When the water stops flowing from the d...

Page 30: ...emove the gasket front bearing pivot pin adjustable draw handle draw valve and prime plug Remove all o rings Note To remove the o rings use a single service towel to grasp the o ring Apply pressure in...

Page 31: ...stration which indicates proper brush usage Rinse all parts with clean warm water Place the pump parts on a clean dry surface Step 8 Wipe clean all exterior surfaces of the freezer ITEM DESCRIPTION 1...

Page 32: ...re the mix rerun is stored in an NSF approved sanitized covered stainless steel container and used the following day DO NOT prime the machine with rerun When using rerun skim off the foam and discard...

Page 33: ...urposes Deteriorated or cracked water lines should be replaced only by an authorized Taylor distributor The Air Mix Pump Checklist j 1 Dispose of o rings and valve gaskets if they are worn torn or fit...

Page 34: ...d Turn the breaker on or replace the fuse e There is inadequate mix in the mix hopper e Fill the mix hopper with mix 24 2 The product is too stiff a The viscosity needs adjustment a Contact service te...

Page 35: ...to repair or replace the beater and to correct the cause of insufficient mix in the freezing cylinder b The front bearing is missing or worn on the freezer door b Install or replace the front bearing...

Page 36: ...utton on the side of the pump motor reducer Press the PUMP key to continue pump operation 13 The air mix pump will not operate when the draw valve is opened and the unit is in the AUTO mode a The pump...

Page 37: ...ring inside the pump cylinder a Cleaner was left inside the pump cylinder a After brush cleaning the pump cylinder allow it to air dry Follow disassembly procedures carefully 26 17 The ball crank of t...

Page 38: ...O Ring X Air Orifice O Ring X White Bristle Brush 3 x 7 Inspect Replace if Necessary Minimum White Bristle Brush 1 x 2 Inspect Replace if Necessary Minimum Black Bristle Brush 1 x 2 Inspect Replace if...

Page 39: ...208 230V 60HZ 1PH BLOCK TERMINAL 3P L1 L2 L3 039423 1 103 208 230V 60HZ 3PH BOARD LOGIC GEN 2 9 HOPR PMP X42002SERP 1 212 BOARD POWER GEN 1 2 X32326 SER 1 212 BRUSH REAR BRG 1IN DX2IN LGX14 013071 1 0...

Page 40: ...N PMP HPR 042170 1 000 DECAL TROUBLESHOOT 038374 1 000 DIAGRAM WIRING C706 C707 064288 27 1 000 208 230V 60HZ 1PH K7026650 UP BRISTOL DIAGRAM WIRING C706 C707 064288 33 1 000 208 230V 60HZ 3PH K702665...

Page 41: ...2 000 O RING 2 1 8 OD X 139W 225 020051 2 000 O RING 1 2 ID X 139W 048632 2 000 GASKET SIMPLIFIED PUMP VALVE 053527 1 000 RING CHECK FEED TUBE 056524 1 000 KIT A DOOR BARREL SS C602 X56200 14 1 000 O...

Page 42: ...103 NUT OVERLOAD RESET 045026 1 000 NUT STUD BLACK 2 563 LONG 058764 2 103 K3060000 UP NUT STUD BLACK 3 250 LONG 058765 2 103 K3060000 UP ORIFICE 022465 100 1 103 O RING 3 8 OD X 070W 016137 1 000 PA...

Page 43: ...CLE A QUICK CONNECT X33321 1 103 DRAW SWITCH RELAY 3 POLE 20A 208 240 50 60 066795 33 1 103 REPLACES 012725 33 SANITIZER KAY 5 125 PACKETS 041082 1 000 SHAFT A DRIVE MIX PUMP HOPPER X41947 1 103 O RIN...

Page 44: ...METER DIGITAL C706 056239 1 103 TOOL O RING REMOVAL FREEZER 048260 WHT 1 000 TOOL SHAFT DRIVE PUMP HOPR LVB 047919 1 000 TOOL SHAFT DRIVE PUMP HOPPER 057167 1 000 TRAY DRIP SOFT SERVE C706 056858 1 10...

Page 45: ...0 1 000 NIPPLE 3 8 X 3 1 2 GALV 016768 1 103 SWITCH PRESSURE 350 PSI S 048231 1 103 VALVE WATER 3 8 REG HEAD PRESS 046686 1 103 INTERNATIONAL SPECIFICATIONS BELT AX42 023877 2 000 220 240V 50HZ 1PH 22...

Page 46: ...6 BEATER MTR 056328 33G 1 103 220 380V 60HZ 3PH 4 WIRE 380 415V 50HZ 3N 460V 60HZ 3PH HARNESS WIRE SOL LIQ C706 C707 064155 G 1 103 220 240V 50HZ 1PH 380 415V 50HZ 3N LABEL CK MTR ROTATE CW EN 020090...

Page 47: ...Model C706 064288 27 Rev 5 11...

Reviews: