background image

Batteries

 

The thermometer incorporates visual low battery indication as follows: 

 

 

 

‘Battery OK’: measurements 

  are possible 

‘Battery Low’: batteries needs to be   

replaced, measurements are possible 

‘Battery Exhausted’: 

measurements are not possible

>

>

>

>

>

>

  

 

Specification 

 

Infrared Scan function   

(IRT Mode) 

Thermocouple  Probe  (K  type,  Grounded) 
(COT Mode)

 

Measurement Range   

-55~250°C (-67~572°F) 

-55~330°C 

(-67 to +626

 o

F)

 

Operating Range 

0~50°C (32~122°F) 

Accuracy 
(Tobj=15-35°C, Tamb=25°C) 

+/-0.6°C (1.1

 o

F

Accuracy  
(Tobj=above -33°C) 

-33~0:+/-(1°C+0.1/degree) 
0~ 65: +/-1°C 
65~200:+/-1.5% of reading

 

below -5 :+/-1°C 
-5~ 65 : +/-0.5°C       
above 65 :+/-1% of reading

 

Resolution (-9.9~199.9°C) 

0.2°C/0.5°F 

0.2°C/0.5°F 

Dimension 

22.18*38*190.09mm 

Weight (with battery)   

98.1g 

Battery Life                           Typically 40 hours, minimum 30 hours continuous use (auto power off after 15 seconds)

CAUTION:

 Since the thermometer is 

splash proof, please make sure the battery 
cover and rubber stopper are on tight.

Readings may be affected if the unit is operated within a radio frequency electromagnetic field strength of 
approximately 3 volts per meter, but the performance of the instrument will not be permanently affected.

1. 

Please pick out the rubber stopper on the battery cover by carefully using a small, pointed tool, such 

as a screwdriver. Then remove the screw that is under the rubber stopper.

2. 

Remove the battery compartment cover.

3.

 Replace the 2 AAA 1.5V batteries. 

4.

 Replace the battery compartment cover.

5.

 Replace the screw and the rubber stopper.

When the 'Low Battery' icon indicates the battery is low, the batteries should be replaced immediately. 
Please note: It is important to turn the instrument off before replacing the batteries, otherwise the 
thermometer may malfunction. Dispose of used batteries properly and keep away from children. Do not 
dispose of batteries in fire, as they may explode or leak.

Two Year Limited Warranty

EMC/RFI

Taylor Precision Products

2220 Entrada Del Sol

Las Cruces, New Mexico 88001, Suite A

Customer Service Phone: 1-800-225-4834

Customer Service Fax: 1-575-526-4347

www.taylorusa.com

There are no expressed warranties except as listed above. This warranty gives you specific legal rights, and you 
may also have other rights which vary from state to state.

For additional product information, or warranty information in Canada or elsewhere outside the USA, please 
contact us through www.taylorusa.com.

©2008 Taylor Precision Products and its affiliated companies, all rights reserved. Taylor® and Leading the Way in 
Accuracy® are trademarks of Taylor Precision Products and its affiliated companies. All rights reserved.

Made to our exact specifications in China.

NOT LEGAL FOR TRADE

This product is warranted against defects in materials or workmanship for two (2) years from date of
original purchase for the original purchaser. It does not cover damages or wear resulting from accident, misuse, 
abuse, or unauthorized adjustment and/or repair. Should this product require service (or replacement at our 
option) while under warranty, please pack the item carefully and return it prepaid, along with receipt showing date 
of purchase and a note explaining reason for return to: