SETTING UP AND WELDING
12
Switch the controller ON by turning the mains switch
clockwise through 60°. The display will illuminate and
the ventilation fan will start.
A guide to the recommended time settings can be found
on page 14 of this guide.
The 800DA controller has a fixed 800A current output,
with only welding time being operator adjustable.
Referring back to the control panel guide on page 9, set
the controller by following these simple steps :-
SETTING WELD TIME
1.
Press and hold the welding time setting
pushbutton (1).
2.
Turn the adjuster knob (5) until the required time
is displayed in the time display window (3).
3.
Release the pushbutton (1). The welding time is
now set.
SETTING THE GAS PURGE TIME
1.
Press and hold the gas purge time setting
pushbutton (6).
2.
Turn the adjuster knob (5) until the required time
is displayed in the time display window (3).
3.
Release the pushbutton (6). The gas purge time is
now set.
4.
If no gas purge is required, this time parameter
must be set to 0 (zero).