background image

 

 

time press 

  to close the laser point, indication as shown as figure B. Short-time press 

again to open laser point, indication as shown as figure C. 

 

3.Change Reference Edge   

Default reference edge is the bottom of meter, indication is shown as figure D. Long-time press 

to change the measuring reference to the top of meter, indication as shown as figure E.   

 

4.Unit Conversion   

 

Factory default that unit is m, indication is shown as figure F. Long-time press 

  to 

switch unit m to Ft, indication as shown as figure G.     

 

Long-time press 

  again to switch the unit Ft to In, indication is shown as figure H.   

(Note: Long-time press 

to switch the unit of measurement, the value will switch 

correspondent at the same time if there is value of measurement.)   

 

When the unit is m2, Long-time press 

  , the unit will switch unit m2 to Ft2.   

 

When the unit is m3, Long-time press 

, the unit will switch unit m3 to Ft3.   

 

When you switch on meter later, the meter will remember the last measuring unit you used. 

Summary of Contents for MD50

Page 1: ...MANUAl Version MD50 70 Tavool Laser Distance Meter CUSTOMER SERVICE service tavool com If any problem question or concern please feel free to contact us via email we will provide you the best solutio...

Page 2: ...diation 3 Please DO NOT remove any safety labels on this product 4 Do not use this device under the flammable and combustible environment Please dispose your wasted device according to your local laws...

Page 3: ...05 D 10 D is the measurement distance unit m Measuring Reference Silence Function Historical Data Review 20Groups Error Code Battery Power Indication Laser Auto Switch of 30s Instrument Auto Switch o...

Page 4: ...tion 1 Laser emitter 7 Clear key Exit key OFF key 2 Laser receiver 8 Spirit bubble 3 Display screen 9 Plus key Reference switch key 4 Spirit bubble 10 Function key Sound key 5 Power key Measuring key...

Page 5: ...the display 3 Please remove the batteries before any long period of non use 4 Waste batteries should be recycled in accordance with national or local regulations 2 Switch on Short time press to switch...

Page 6: ...ault that unit is m indication is shown as figure F Long time press to switch unit m to Ft indication as shown as figure G Long time press again to switch the unit Ft to In indication is shown as figu...

Page 7: ...hort time press again to switch Single Pythagorean Theorem Measurement Mode indication is shown as figure L Short time press again to switch Dual Pythagorean Theorem Measurement Mode indication is sho...

Page 8: ...ous measurement Single Measurement Mode only aim the laser onto target then long time press to enter the continuous measurement the Max measuring value Mix measuring value and Current measuring value...

Page 9: ...Short time press to measure the length of the hypotenuse and right angle side of a right triangle The height calculated value of the right triangle will be displayed immediately on the screen as show...

Page 10: ...ete the measurement one by one Historical Data range 0 19 The screen shown as figure U Figure U 8 Addition and Subtraction Functions Short time press button the next measuring data add the previous me...

Page 11: ...While Using 1 Q Will it work for outdoor A Yes but it is not recommended in direct sunlight if it is too bright outdoor because it is hard to see the target laser dot with the bare eye If the sunligh...

Page 12: ...om a point some distance from the base of the tree and then the distance to the base of the tree and the device can calculate the height of that point it s a great aid for when you can t get a direct...

Reviews: