background image

 

 

 
 

ATTENTION: 

* For different measurement targets and test environment, the range and 
accuracy will be affected. The measuring accuracy is higher than or equal to 
the industry standard in the factory test environment. 

 
*Industry Standard: When measurement range is within 10m, the 
measurement accuracy is ±2mm; More than 10m, the measurement 
accuracy is calculated as follows: ±2mm±0.05 * (D-10) (D is the measurement distance, unit: m). 

Measuring Reference

 

 

Silence Function

 

 

Historical Data Review

 

20Groups

 

Error Code

 

 

Battery Power Indication

 

 

Laser Auto Switch of

 

30s

 

Instrument Auto Switch off

 

180s 

Measuring Range 

50m: 0.05m-50m 

70m: 0.05m-70m 

Measuring Accuracy

 

±2.0mm

 

Measuring Unit

 

m,ft,in

 

Area Unit

 

,ft²

 

Volume Unit

 

,ft³

 

Laser Type

 

620~690nm

 

Laser Class

 

class II ,<1mW

 

Operating Temperature 

0~+40℃ 

Storage Temperature 

-20~+65℃ 

Batteries 

AAA(Alkaline),2×1.5V 

Working time(Fully charged) 

>5000 times 

Weight (Without batteries) 

Approximate 72g 

Dimension (L*W*H) 

110X46X25mm 

Summary of Contents for MD50

Page 1: ...MANUAl Version MD50 70 Tavool Laser Distance Meter CUSTOMER SERVICE service tavool com If any problem question or concern please feel free to contact us via email we will provide you the best solutio...

Page 2: ...diation 3 Please DO NOT remove any safety labels on this product 4 Do not use this device under the flammable and combustible environment Please dispose your wasted device according to your local laws...

Page 3: ...05 D 10 D is the measurement distance unit m Measuring Reference Silence Function Historical Data Review 20Groups Error Code Battery Power Indication Laser Auto Switch of 30s Instrument Auto Switch o...

Page 4: ...tion 1 Laser emitter 7 Clear key Exit key OFF key 2 Laser receiver 8 Spirit bubble 3 Display screen 9 Plus key Reference switch key 4 Spirit bubble 10 Function key Sound key 5 Power key Measuring key...

Page 5: ...the display 3 Please remove the batteries before any long period of non use 4 Waste batteries should be recycled in accordance with national or local regulations 2 Switch on Short time press to switch...

Page 6: ...ault that unit is m indication is shown as figure F Long time press to switch unit m to Ft indication as shown as figure G Long time press again to switch the unit Ft to In indication is shown as figu...

Page 7: ...hort time press again to switch Single Pythagorean Theorem Measurement Mode indication is shown as figure L Short time press again to switch Dual Pythagorean Theorem Measurement Mode indication is sho...

Page 8: ...ous measurement Single Measurement Mode only aim the laser onto target then long time press to enter the continuous measurement the Max measuring value Mix measuring value and Current measuring value...

Page 9: ...Short time press to measure the length of the hypotenuse and right angle side of a right triangle The height calculated value of the right triangle will be displayed immediately on the screen as show...

Page 10: ...ete the measurement one by one Historical Data range 0 19 The screen shown as figure U Figure U 8 Addition and Subtraction Functions Short time press button the next measuring data add the previous me...

Page 11: ...While Using 1 Q Will it work for outdoor A Yes but it is not recommended in direct sunlight if it is too bright outdoor because it is hard to see the target laser dot with the bare eye If the sunligh...

Page 12: ...om a point some distance from the base of the tree and then the distance to the base of the tree and the device can calculate the height of that point it s a great aid for when you can t get a direct...

Reviews: