background image

ZIPPOXL

2

ZIPPO

XL

XLB

 XLB-R

Alimentazione / Power / Stromspeisung / Alimentation / Alimentación

230V AC

Frequenza / Frequency / Frequenz / Fréquence / Frequencia

50/60 Hz

Condensatore / Capacitor / Kodensator / Condensateur / Condensador

12,5 µf

-

-

Motore / Motor / Motor / Moteur / Motor

230V AC

12V DC

24V DC

Tempo di apertura 90° / Opening time 90° / Laufzeit, 90°
Temps de ouverture 90° / Tiempo de apertura 90°

16,5 sec.

16,5 sec.

10 sec.

Assorbimento / Absorption / Stromentnahme / Absorption / Absorción

1,4 A 

1,3 A

1,5 A

Potenza assorbita / Absorbed rated power / Aufgenommene Leistung
Puissance absorbée / Potencia nominal absorbida

260 W 

300 W

Rapporto di riduzione / Reduction ratio / Übersetzungsverhältnis
Rapport de réduction / Relación de reducción

1/1175

Intervento di termoprotezione / Thermal protection trips at / Eingreifen des Warmeschutzes
Intervention protection thermique / Interventiòn termoprotecciòn

160°C 

Grado di protezione / Protection level / Schutzart
Degré de protection / Grado de protección

IP 44

Ciclo di lavoro / Working cicle / Arbeitzyklus / Cycle de travail / Ciclo de trabajo

50%

100%

Temperatura di esercizio / Operating temperature / Betriebstemperatur
Température de fonctionnement / Température de fonctionnement

-20°C + 55°C

Coppia max / Max torque / Max Motordrehmoment / Couple max / Par màx

402 Nm

458 Nm

Lunghezza max. semi-anta

 / Max. length of half-leaf

 / 

Max. halb Torflügellänge

Longueur max. demi-battant / Longitud max. media-hoja

4 mt

Peso max. anta / Max. leaf weight / Flügelgewicht max. - Poids max battant

Peso máximo de la hoja

400 Kg

Peso / Weight / Gewicht / Poids / Peso

21 Kg 

Description and characteristics

The automation 

ZIPPO XL

 have been designed to move swing gates. 

THE USE OF THE EQUIPMENT FOR PURPOSES OR CIRCUMSTANCES OTHER THAN THOSE MENTIONED IS STRICTLY 
PROHIBITED.

English

The data described in this handbook are purely a guide. TAU reserves the right to change them in any moment.
The manufacturer reserves the right to modify or improve products without prior notice. Any inaccuracies or errors found in this 
handbook will be corrected in the next edition.
When opening the packing please check that the product is intact. Please recycle materials in compliance with current regulations.

This product may only be installed by a qualified fitter. The manufacturer declines all liability for damage to property and/or 

personal injury deriving from the incorrect installation of the system or its non-compliance with current law (see Machinery 

Directive).

Summary of Contents for ZIPPO

Page 1: ... MANUAL ZIPPO Automations for swing gates Via Enrico Fermi 43 36066 Sandrigo VI Italia Tel 39 0444 750190 Fax 39 0444 750376 info tauitalia com www tauitalia com D MNL0ZIPPOXL GB 15 11 2017 Rev 01 IT Istruzioni originali ...

Page 2: ...mperatur Température de fonctionnement Température de fonctionnement 20 C 55 C Coppia max Max torque Max Motordrehmoment Couple max Par màx 402 Nm 458 Nm Lunghezza max semi anta Max length of half leaf Max halb Torflügellänge Longueur max demi battant Longitud max media hoja 4 mt Peso max anta Max leaf weight Flügelgewicht max Poids max battant Peso máximo de la hoja 400 Kg Peso Weight Gewicht Poi...

Page 3: ...safety requirements of the following EEC directives 2014 35 EU Low Voltage Directive 2014 30 EU Electromagnetic Compatibility Directive Also declares that it is not permitted to start up the machine until the machine in which it is incorporated or of which it will be a component has been identified with the relative declaration of conformity with the provisions of Directive 2006 42 EC The followin...

Page 4: ... The installer must provide all information regarding manual operation of the system in the event of an emergency and supply the system User with the User Guide enclosed with the product 21 Never allow children or other persons to stay in the vicinity of the product during operation 22 Keep all radio controls or other pulse supplier device out of the reach of children to prevent inadvertent activa...

Page 5: ...lu Phase 1 Cap 5 Light Blue Motor common 6 Grey Phase 2 Cap Use only control units with electric clutch The distance between the control unit and the motor must not exceed 10 12 m TAU srl recommends its composite cable Code M 03000010CO Place the control unit in the immediate vicinity of the motors Be careful not to run cables for auxiliary devices in side raceways housing other cables supplying p...

Page 6: ...the faulty part 6_ SCRAPPING All materials must be disposed of in observance of current stand ards If the automation is to be scrapped there are no particular dan gers or risks associated with the automation itself In the case of material recovery separate components accord ing to the waste category electrical parts copper aluminium plastic etc 7_ DISASSEMBLY If the automation is disassembled for ...

Page 7: ... 1 2 238 231 350 240 439 5 236 450 D B A C L ZIPPO XL DISEGNI DRAWINGS ZEICHNEN PROJETS DIBUJOS fig pic Abb image imagen 1 fig pic Abb image imagen 2 Staffa di ancor aggio a pilastro Fixing bracket on the pillar Staffa di ancoraggio per braccio articolato su anta Fixing bracket for articulated arm A 300 mm MAX B 500 mm MAX C 40 mm D 170 MAX L 1750 mm MAX ...

Page 8: ...L DISEGNI DRAWINGS ZEICHNEN PROJETS DIBUJOS fig pic Abb image imagen 3 fig pic Abb image imagen 5 fig pic Abb image imagen 4 fig pic Abb image imagen 6 fig pic Abb image imagen 7 fig pic Abb image imagen 8 A F G B C D E ...

Page 9: ...blau Phase1 cond com FCO bleu foncé Fase1 cond com FCA azul oscuro 5 Comune motore azzurro Motor common light blue Sammelkontakt blau Commun moteur bleu Común motor azul 6 Fase2 cond com FCC grigio Phase2 cap com CLS grey Phase2 Kond Gem ETZ Grau Phase2 cond com FCF gris Fase2 cond com FCC gris B M Open Com Close To the Control panel B M Open Com Close To the Control panel MOTORE ZIPPO XL VISTO DA...

Page 10: ...SIDE_SWNG LEAFS IMPIANTO TIPO CON ANTE BATTENTI DALL ESTERNO INSTALLATION TYPE OUTSIDE_SWING LEAFS fig pic Abb image imagen 12 fig pic Abb image imagen 11 1 1 2 3 3 4 5 5 1 Motore ZIPPO XL 2 Centrale di comando 3 Coppia di fotocellule a parete 4 Lampeggiante e antenna 5 Coppia di fotocellule su colonnina 6 Selettore a chiave A B ...

Page 11: ...IBUJOS fig pic Abb image imagen 13 1 1 2 3 3 4 5 5 IMPIANTO TIPO CON CANCELLO A 4 ANTE RESIDENTIAL FOLDING GATE TYPICAL INSTALLATION 1 Motore ZIPPO XL 2 Centrale di comando 3 Fotocellule a parete 4 Lampeggiante e antenna 5 Coppia di fotocellule su colonnina ...

Page 12: ...Via Enrico Fermi 43 36066 Sandrigo VI Italy Tel 39 0444 750190 Fax 39 0444 750376 info tauitalia com www tauitalia com ...

Reviews: