TAU Wireless is a device that allows to solve the problem of the electrical connection of the prox

-

imity edges on moving and static gates. The system consists of:

1_  Base (TWM) that manages the sensors (via radio) and the controls from and to the gate panel 

(via cable).

2_  Sensor (TWC) that sends the signal of the proximity edge (connected to it) with NC or resistive 

contact, to be used as fixed and/or movable proximity edge.

All devices, both base and sensors, are fitted with a transceiver capable of receiving and trans

-

mitting data on the standard 868 MHz frequency.

TAU Wireless can be used as part of a safety device sensitive to pressure (PSPE), through check

-

ing the status of the proximity edge. The proximity edge, of the 8.2kohm constant resistance or 

NC (normally closed) contact type, is continually monitored by the TWC sensor and its activation 

status is transmitted to the TWM base.  This base interprets the received information and trans

-

mits it to the automation electronic unit.

The TAU Wireless system is compatible with all TAU control units.

  

  TECHNICAL DATA

TWM card power supply

12/24V AC/DC

TWM card absorbed current

70 mA

TWC sensor power supply

2 x AA 1,5V batteries

Maximum load

20 m

TWM housing protection rating

IP 45

TWC housing protection rating

IP 45

Operating temperature

-20 °C ÷ +55 °C

 INSTALLATION

The  whole  installation  must  be  carried  out  with  no  voltage  in  the  system;  if  a  battery 

backup is connected, disconnect it.

PRELIMINARY CHECKS

Check carefully that the use parameters match the data in the “Technical data” chapter.  If in 

doubt, don’t use the product and ask TAU technical service for clarification.

To install the proximity edge, follow the instructions accompanying the product.

For a correct installation, proceed as follows:

1_  Place the TWC sensor near the proximity edge fixing first the support bracket (1 in fig. 1) with 

2 screws (2 in fig. 1) suitable to the gate. Insert the TWC card (3 in fig. 1) into the appropriate 

base supports. 

2_  Connect the TWC sensor to the proximity edge guiding the cables inside the gate (fig. 2). We 

recommend 0.5mm² cables are used. 

3_  Determine the best area for installing the TWM base (it is best to use the relevant housing 

and locate it on the outside near the electronic control unit provided the latter is not built 

into the gearmotor).

Note:  If the motor casing is made from metal (e.g. BIG series), the TWM base must 

be located outside the motor casing with the relevant housing.  Even in the event the 

casing is not made from metal, it is not advisable to position the TWM base near the 

motor  compartment  or,  more  generally  speaking,  near  metal  objects  as  this  might 

Summary of Contents for WIRELESS

Page 1: ...GUIDA ALL INSTALLAZIONE IT Istruzioni originali TAU WIRELESS vers 7 00 e successive vers 7 00 and later D MNL0TWM C 21 05 2019 Rev 17...

Page 2: ...TAU WIRELESS 2 1 3 2 fig 3 fig 1 1 4 2 3...

Page 3: ...TAU WIRELESS 3 4 4...

Page 4: ...ORS 32 E pow M1 ingresso 1 associato all uscita Relay 1 Contatto N C Normalmente Chiuso NC contact Normally Closed Contatto N C Normalmente Chiuso NC contact Normally Closed M1 M2 J2 J5 P1 J4 TWC J2 J...

Page 5: ...M 18 Vdc 18 Vdc USCITA 1 USCITA 2 RELAY 1 1 2 3 RELAY 2 O N 4 3 2 1 P1 LED 4 LED 3 LED 2 LED 1 LED PRG P4 TRA FR TCA CH2 PROG CH1 F4 16A F3 2A F5 10A DL6 DL5 DL4 DL3 DL2 DL1 DL8 DL7 1 2 3 4 5 6 7 8 9...

Page 6: ...almente Chiuso NC contact Normally Closed M1 M2 J2 J5 P1 J4 TWC M J2 J5 P1 J4 J4 CHIUSO ingresso 2 NC APERTO ingresso 2 8K2 J2 CHIUSO ingresso 1 NC APERTO ingresso 1 8K2 J5 NON USATO PULSANTE PROGRAMM...

Page 7: ...A 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 1 2 3 4 5 P1 P2 F1 3 15A F2 500mA 1 2 3 4 5 6 7 8 9 10 11 12 K580M M1 M2 M3 1 2 3 P4 COM CF 24 Vac 24 Vac 24 Vac 24 Vac USCITA 1 USCITA 2 LED 4 LED 3 LED 2...

Page 8: ...e l alimentazione elettrica e gli altri parametri d utilizzo corrispondano ai valori ripor tati nella tabella caratteristiche tecniche La realizzazione di dispositivi di sicurezza per porte e cancelli...

Page 9: ...rado di protezione contenitore TWC IP 45 Temperatura di funzionamento 20 C 55 C INSTALLAZIONE Tutte le operazioni d installazione vanno eseguite in assenza di tensione all impianto nel caso sia presen...

Page 10: ...ne radio tra base TWM e sensore TWC e o delle batterie scariche il led verde relativo lampegger velocemente I contatti delle uscite risulteranno aperti COLLEGAMENTI figg 4 5 COLLEGAMENTI ALLA MORSETTI...

Page 11: ...Premere il pulsante di programmazione P1 sul sensore TWC il led rosso della base TWM si spegner Il led verde invece dopo qualche secondo da lampeggiante rimarr acceso fisso a segnalare l avvenuta pro...

Page 12: ...da TAU In caso di intervento a domicilio anche nel periodo coperto da garanzia l utente tenuto a cor rispondere il Diritto fisso di chiamata per spese di trasferimento a domicilio pi manodopera La ga...

Page 13: ...y and other operating parameters correspond to the values specified in the table technical specifications The installation of safety devices on power operated doors and gates is subject to the followi...

Page 14: ...20 m TWM housing protection rating IP 45 TWC housing protection rating IP 45 Operating temperature 20 C 55 C INSTALLATION The whole installation must be carried out with no voltage in the system if a...

Page 15: ...aster TCM and the slave TWC devices and or when batteries are low the relevant green led will flash quickly Exit contacts will be open CONNECTIONS figures 4 5 CONNECTIONS TO THE TERMINAL BLOCK TWM BAS...

Page 16: ...d on permanently in order to signal that TWC devices have been successfully programmed NOTE to use the TWC sensor with resistive sensitive edges firstly put the J4 jumper of the TWC for M1 contact inp...

Page 17: ...e period a Call out fee will be charged for travelling expenses and labour costs The guarantee does not cover the following cases If the fault was caused by an installation that was not performed acco...

Page 18: ...TAU WIRELESS 18...

Page 19: ...TAU WIRELESS 19...

Page 20: ...TAU WIRELESS 20 Via Enrico Fermi 43 36066 Sandrigo VI Italy Tel 39 0444 750190 Fax 39 0444 750376 info tauitalia com www tauitalia com...

Reviews: