TECHNICAL DATA -
MRC/MRCM Series
TYPE
MRC10
MRC20
MRC30
MRC40
MRC50
Torque
10 Nm
20 Nm
30 Nm
40 Nm
50 Nm
Max lifting with Ø 60 mm
18 Kg
38 Kg
56 Kg
76 Kg
94 Kg
Power
146 W
205 W
230 W
292 W
308 W
Current
0,63 A
0,92 A
1,1 A
1,3 A
1,4 A
Power supply
230 V - 50 Hz
Max continuous operating time
4'
Operating temperature
–10 °C ÷ +60 °C
Output speed
15 rpm
15 rpm
15 rpm
15 rpm
12 rpm
Protection level
IP 44
IP 44
IP 44
IP 44
IP 44
TYPE
MRC20M
MRC30M
MRC40M
MRC50M
Torque
20 Nm
30 Nm
40 Nm
50 Nm
Max lifting with Ø 60 mm
38 Kg
56 Kg
76 Kg
94 Kg
Power
205 W
230 W
292 W
308 W
Current
0,92 A
1,1 A
1,3 A
1,4 A
Power supply
230 V - 50 Hz
Max continuous operating time
4’
Operating temperature
–10 °C ÷ +60 °C
Output speed
15 rpm
15 rpm
15 rpm
12 rpm
Protection level
IP 44
IP 44
IP 44
IP 44
CONTENTS OF THE PACKAGE (fig.1)
1_ Gear motor
2_ Pulley cotter pin
3_ Square pin
4_ Pin support bracket
5_ Driving pulley
6_ Indexing ring
7_ Key for
limit switch adjustment
8_
Wall bracket
N.B.: Various kinds of wall brackets for fixing the gearmotor are available on request.
INSTALLATION AND ADJUSTMENT INSTRUCTIONSFOR TUBULAR
MOTOR
1. INSTALLATION
Attention:
- never hit the exit pins;
- do not drill holes in the tube with the gearmotor motor inserted;
english