WARNING: The learning process has to be done even if ENCODER function is
disabled (DIP 11 OFF).
It is recommended to start the learning process with the gate partially opened.
Press and hold simultaneously P1 and P2 until DL8 blinks fast. Release the buttons to start automati-
cally the learning process:
1_ the automation starts closing to reach the Closing Limit switch (CLS);
If the automation opens instead of closing, stop the learning process (by cutting the
photocells or opening the STOP contact), invert DIP 10 and continue the learning process
by pressing P1 briefly.
2_ the automation automatically opens to reach the Opening Limit switch (OLS);
WARNING: - SETTING SLOWDOWN: (skip this procedure to disable slowdown) During the
opening cycle press P1 or close the OPEN/CLOSE contact at the desired position where
to start the slowdown.
3_ the automation automatically closes to reach the Closing Limit Switch (CLS);
SETTING SLOWDOWN: (skip this procedure to disable slowdown) During the opening cy-
cle press P1 or close the OPEN/CLOSE contact at the desired position where to start the
slowdown.
4_ LED8 turnss steady ON. Learning process procedure is terminated.
WARNING: if during the learning process either the STOP, or PHOTOCELLS or SAFETY
EDGE contact will be opened the automation stops. By pressing P1 or closing the OPEN/
CLOSE contact the learning process starts again from pont nr. 1
7. ADVANCED FUNCTIONS
Clock function: a timer can be connected to the open-close pushbutton in order to keep the gate open
at certain times during the day, after which it reverts to automatic closing.
Note: the gate remains open as long as the Op/Cl input continues to be activated.
“Open only” function: setting dip 1 and dip 4 to ON, the Op/Cl input will function solely as an opening
command and the gate will close only after the automatic closure time has elapsed.
“Gate contact open” function: setting dip 7 and dip 8 to OFF, the 2nd ch radio (connectors 18 - 19) will
act as a dry contact which indicates when the gate is open. This function can be used to connect “ZONE
LIGHTING” or as a gate open signal.
8. DIAGNOSTICS LED
DL1 (PHOTO)
PHOTOCELL green LED signal
DL2 (SENSITIVE EDGE)
SENSITIVE EDGE green LED signal
DL3 (CLOSE LIMIT SWITCH)
CLOSE LIMIT SWITCH green LED signal
DL4 (OPEN LIMIT SWITCH)
OPEN LIMIT SWITCH green LED signal
DL5 (STOP)
STOP button green LED signal
DL6 (PEDESTRIAN)
PEDESTRIAN button red LED signal
DL7 (OPEN/CLOSE)
OPEN/CLOSE button red LED signal
DL8 (RADIO CONTROLS)
RADIO CONTROLS programming red LED
LED - DL8
The DL8 LED indicates errors in the control board with a series of pre-set flashes:
always on:
normal operation;
2 flashes:
photo-test error;
Disable photo-test (dip-switch 6 OFF), check the operation of the photocells and their
connection;
ENGLISH