![tau K580M Installation Manual Download Page 15](http://html.mh-extra.com/html/tau/k580m/k580m_installation-manual_821486015.webp)
15
2
2 / 4 STROKE
On
with automatic closing enabled, a sequence of open/close commands
causes the gate to OPENCLOSE-OPEN-CLOSE etc (see also dip switch 4).
Off in the same conditions, the same command sequence causes the gate
to OPEN-STOP-CLOSESTOP-OPEN-STOP (step-by-step).
3
OPENING
PHOTOCELLS
OPERATION
On
during opening, cutting photocell stops the gate until the obstacle is
removed. When the obstacle is removed the gate resumes opening;
Off during opening, the photocell does not cut in.
4
NO
REVERSE
On
NO-REVERSE function activated; the gate ignores the closure commands
during opening; reversal of movement occurs only during closure;
Off the open-close pushbutton reverses the direction of movement of the
gate even while it is opening.
5
PRE-
FLASHING
On
pre-flashing function enabled.
Off pre-flashing function disabled.
6
PHOTOCELL
TEST
On
“photocell test” function is enabled;
Off “photocell test” function is disabled.
Note: to be used when the photocells are not used.
7 - 8 2nd RADIO CHANNEL operation (terminals no. 18 - 19)
Dip 7 Dip 8 Function
Off
Off
Gate contact open:
The contact activates on opening the gate and remains
active during the open time, during the TCA and during reclosure. It deactivates
once the gate has completed its closure movement.
Off
On Bistable function active:
the radio control impulse causes the contact to activate
and remain active until the subsequent impulse.
On
Off Monostable function active for 2 sec.:
the radio control impulse causes the
contact to activate and remain active for 2 sec.
On
On Monostable function active for 180 sec.:
the radio control impulse causes the
contact to activate and remain active for 180 sec.
9
GATE
TYPE
On
setting for heavy gates
Off setting for standard gates
10
OPENING
DIRECTION
SETUP
On
left-hand leaf opening function;
Off right-hand leaf opening function;
11
ENCODER
On
ENCODER enabled: encoder obstacle detection function activated (use
the trimmers FR and SENS to adjust the sensitivity to obstacles);
Off ENCODER disabled - obstacle detection disabled;
NOTE: moving DIP 11 from ON to OFF (or vice versa), learning process has to be
initialized again.
12
SENSITIVE
EDGE
On
RESISTIVE SENSITIVE EDGE (terminal no. 11);
Off FIXED EDGE (NC contact – terminal no. 11).
OBSTACLE DETECTION
If the obstacle detection function (which can be set through trimmers FR and SENS) gets activated dur-
ing an opening manoeuvre, the gate closes approx. 20 cm., if it is activated during a closing manoeu-
vre, the gate opens fully.
WARNING: the control panel logics may interpret mechanical friction as an obstacle.
6. STROKE SETTING PROCEDURE WITH OR WITHOUT SLOWDOWN (SETUP)
ENGLISH