24
1 flash (red):
phototest error
Disable phototest (dip-switch 6 OFF), check the operation of the pho-
tocells and their connection;
1 flash (yellow):
unknown status, next operation REALIGNMENT;
2 flashes (red):
obstacle for motor 1;
Make sure there are no obstacles across the path of the automation
and that it slides smoothly;
With an active automatic closing feature, after the intervention
meant to detect the obstacle, the automatic closing is deactivated. A
command pulse is required to carry out the closing;
2 flashes (yellow):
obstacle for motor 2
Make sure there are no obstacles across the path of the automation
and that it slides smoothly;
With an active automatic closing feature, after the intervention
meant to detect the obstacle, the automatic closing is deactivated. A
command pulse is required to carry out the closing;
3 flashes (red):
no motor 1 encoder signal;
Check wiring, check encoder by TEST-ENCODER (optional);
3 flashes (yellow):
no motor 2 encoder signal;
Check wiring, check encoder by TEST-ENCODER (optional);
4 flashes (red):
no motor 1 signal;
Check wiring, check the motor rotates freely and is powered directly
by the battery, check fuse F5;
4 flashes (yellow):
no motor 2 signal;
Check wiring, check the motor rotates freely and is powered directly
by the battery, check fuse F5;
5 flashes (red):
max current limit for motor 1 exceeded;
Excessive absorption peaks of the gearmotor, check there are no
obstacles on the automation path, check the current absorption of
the motor when in a no-load condition and when applied to the gate,
5 flashes (yellow):
max current limit for motor 2 exceeded;
Excessive absorption peaks of the gearmotor, check there are no
obstacles on the automation path, check the current absorption of
the motor when in a no-load condition and when applied to the gate,
7 flashes (red):
Sensitive edge safety intervention
A command pulse is required to carry out the closure;
8 flashes (red):
Eeprom external memory fault;
Replace the external memory module;
8 flashes (yellow):
Eeprom data error (internal/external);
Perform procedure RADIO MEMORY RESET;
Apart from the logic mistakes, the DL8 LED indicates also the status of the control unit during the sav
-
ing of the radio controls.
always on (green):
channel CH1 waiting to be saved;
fast flashing (green):
CH1 channel memory full;
always on (yellow):
channel CH2 waiting to be saved;
fast flashing (yellow):
CH2 channel memory full;
always on (red):
channel CH3 waiting to be saved;
fast flashing (red):
CH3 channel memory full;
ENGLISH