tau D703 Installation Manual Download Page 7

14

D703

LOGIC ADJUSTMENTS

TRIMMER

T.L. 

Work Time adjustment: from approx. 5 to 240 seconds;

T.C.A. 

Automatic Closing Time adjustment: from approx. 5 to 120 seconds 

(see dip switch 1);

FR.

  

obstacle detection sensitivity adjustment (only for motors with encoder).

Note: turn the TRIMMER clockwise to increase adjustments; turn it anti-
clockwise to decrease.

Dip switches

1

AUTOMATIC

CLOSING

On

after opening, the gate automatically closes when the delay set on 

the T.C.A. trimmer expires;

Off

a command is required to close the gate;

2

2 / 4 STROKE

On

with  automatic  closing  enabled,  a  sequence  of  open/close  com

-

mands causes the gate to OPEN-CLOSE-OPEN-CLOSE etc.;

Off

in the same conditions, the same command sequence causes the 

gate  to  OPEN-STOP-CLOSE-STOP-OPEN-STOP  (step-by-step) 

(see also dip switch 9);

3

MAN

PRESENT

On

Man Present; the automation system will continue to open or close 

as long as the OPEN or CLOSE buttons are held down. The gear 

motor will stop when the button is released;

Off

normal  (or  pulse);  when  the  OPEN,  CLOSE  or  the  PP  button  is 

pushed, the automatic system performs a complete opening or clos-

ing manoeuvre;

Note: in the Man Present mode, the PP input (n° 13) is disabled, as is the radio receiver.
4

not used;

5

ENCODER

On

encoder  disabled  (obligatory  if  the  motor  is  not  itted  with  an  en

-

coder);

Off

encoder enabled (only for motors with encoder);

6

PRE-FLASHING

FOTOTEST

On

pre-lashing and “photocell test” function enabled;

Off

pre-lashing and “photocell test” function disabled;

7

CLOSE

AFTER

PHOTOCELL

On

after the photocell contact triggers (input 16 - 18), the automation 

system closes after 5 seconds;

Off

function disabled;

8

NO

REVERSE

On

the gate works as set by dip switch 2

Off

the gate ignores the close command during the opening cycle;

9

OPENING

PHOTOCELLS

OPERATION

On

during opening, the photocell cuts in to stop the gate until the ob-
stacle is removed. During closing, it stops the gate and then totally 
reopens it.

Off

during opening, the photocell does not trigger while during closing, it 

behaves as if the dip switch were on;

10

BRAKING

On

braking enabled;

Off

braking disabled;

Note: the braking system activates whenever the motor must stop (FCC - FCA - STOP 
– change of direction) and reduces the inertia accumulated by the gear motor during 
movement.

EN

G

L

IS

H

Summary of Contents for D703

Page 1: ...400 Vac single three phase motor Steuerplatine f r einphasigen dreiphasigen 230 400 Vac Motor Logique de commande pour moteur monophase triphase 230 400 Vca Panel de mandos para motor monof sico trif...

Page 2: ...upply 400Vac Power supply Flashing light 230Vac max 20W Cap 12 5 F 2 MASTER 20T BIG18QI Thermal protector OLS CLS Common Common Photocell Fixed safety edge Common Common Photocell Common Open Close St...

Page 3: ...ac 230Vac Radio connector Gate open warning light max 3W Antenna 2nd radio channel OLS Open limit switch CLS Close limit switch O C Open Close Ped Pedestrian Cap Capacitor TX Transmitter RX Receiver M...

Page 4: ...regulations and directives When designing its products TAU observes all applicable standards please see the attached declaration of conformity but it is of paramount importance that installers strict...

Page 5: ...wer 1 5 Kw ca Flashing light rapid fuse F1 5x20 F2A 250V AC Primary input line rapid fuse F2 F3 F4 5x20 F10A 250V AC Input voltage of motor circuits 230 400V AC Input voltage of auxiliary circuits 24V...

Page 6: ...s checked by the safety system the control unit will not work if it is disconnect ed To disable the safety system move dip switch 6 to OFF 19 20 CLS FCC CLOSE LIMIT SWITCH input normally closed contac...

Page 7: ...on is pushed the automatic system performs a complete opening or clos ing manoeuvre Note in the Man Present mode the PP input n 13 is disabled as is the radio receiver 4 not used 5 ENCODER On encoder...

Page 8: ...available voltage c_ Check that the NC contacts of the card are actually normally closed 5 green LEDs on d_ Set the dip 3 man present function to OFF dip 5 encoder to ON dip 6 phototest to OFF e_ Che...

Page 9: ...side of the coil of both relays 4 Connect 5 OPEN from the D703 to the other side of the coil of one relay 5 Connect 6 CLOSE to the other side of the coil on the second relay 6 Take the COM from the r...

Reviews: