tau ARM2000ENC Use And Maintenance Manual Download Page 11

11

ARM2000 Series

DESCRIPTION

The ARM2000  automated  system  for  swing  gates  is  an  electro-

mechanical non-reversing actuator that transmits motion to the leaf 

via a worm screw system.

The actuator is available in 12 Vdc and 230 Vac versions. All ver-

sions are equipped with closing limit switches.

The non-reversing system ensures the leaf is mechanically locked 

when the motor is not operating. A convenient and safe release 

system with customised key makes it possible to manually move  

the leaf in the event of a malfunction or of a power failure.

ATTENTION:

The  correct  operation  and  the  declared  specifica-

tions only apply if TAU accessories and safety de-

vices are used.
In the absence of a mechanical clutch, the use of 

a control unit with an adjustable electronic clutch, 

or the installation of a sensitive edge, is required in 

order to ensure crush-proof safety.
The ARM2000 automated system was designed and 

built for controlling vehicle access. Avoid any other 

use whatever.

ACTUATOR PARTS (fig.1)

Nr. Description

Nr. Description

1

Actuator

6

Terminal board cover

2 Release device

7 Opening mechanical stop

3 Worm screw cover

8 Closing mechanical stop

4

Wing connection bracket

9 Opening  electrical  limit 

switch

5 Rear bracket

10 Closing 

electrical 

limit 

switch

DIMENSIONS (fig.2)

INSTALLATION (fig.3)

Electrical set-up (standard system - ARM2000)

Pos. Description

Cables

Actuator

4x1,5 mm²

Control unit

3x1,5 mm²

(power supply)

3  TX photocells

4x0,5 mm²

4  RX photocells

2x0,5 mm²

5  Key-operated selector switch

3x0,5 mm²

6  Flashing light and aerial

2x1 mm² + 1RG58

7  Mechanical stops

-

Electrical set-up (standard system - ARM2000ENC)

Pos. Description

Cables

Actuator

2x2,5 mm² + 3x0,5 mm²

Control unit

3x1,5 mm²

(power supply)

3  TX photocells

4x0,5 mm²

4  RX photocells

2x0,5 mm²

5  Key-operated selector switch

3x0,5 mm²

6  Flashing light and aerial

2x1 mm² + 1RG58

7  Mechanical stops

-

Notes:

•   Use suitable tubes and/or hoses to lay electric cables

•   Choose short routes for cables and keep power cables sepa-

rate from control cables.

Preliminary checks

Prior to installing the automation, make all structural modifications 

in order to ensure safety distances and protect and segregate ar-

eas in which people may be exposed to the risk of crushing, shear-

ing, dragging or similar dangers.

•   Make sure the existing structure is sufficiently sturdy and stable;

•   the mechanical parts must conform to the provisions of Stand-

ards EN 12604 and EN 12605;

•   leaf length in compliance with the actuator specifications;

•   regular and uniform movement of the leaves, without any fric-

tion and dragging during their entire travel;

•   stiff hinges in good conditions;

•   presence of both opening and closing mechanical limit stops;

•   presence of an efficient earthing for electrical connection of the 

actuator.

Perform any necessary metalwork job before installing the auto-

mated system.

The condition of the gate structure directly affects the reliabil-

ity and safety of the automated system.

Installation dimensions (fig.4)

Determine the fitting position of the actuator with reference to fig.4.

Check with care if the distance between the open leaf and any ob-

stacles (walls, fences etc.) is higher than the actuator dimensions.

A (mm)

B (mm)

Thickness

of the gate

90

140

150 ÷ 210

40 mm

90

145

150 ÷ 205

40 mm

90

150

150 ÷ 200

40 mm

90

155

150 ÷ 195

40 mm

90

160

150 ÷ 190

40 mm

90

165

150 ÷ 185

40 mm

90

170

150 ÷ 180

40 mm

90

175

150 ÷ 175

40 mm

90

180 ÷ 185

150 ÷ 170

40 mm

90

190

150 ÷ 155

40 mm

100

170

150 ÷ 155

40 mm

100

175

150

40 mm

A (mm)

B (mm)

Thickness

of the gate

90

140 ÷ 145

155 ÷ 205

50 mm

90

150

155 ÷ 200

50 mm

90

155

155 ÷ 195

50 mm

90

160

155 ÷ 190

50 mm

90

165

155 ÷ 185

50 mm

90

170

155 ÷ 180

50 mm

90

175

155 ÷ 175

50 mm

90

180 ÷ 185

155 ÷ 170

50 mm

100

170

155

50 mm

÷ =   RANGE  BETWEEN  PERMITTED  MINIMUM AND  MAXI-

MUM VALUES

Useful travel = 350 mm

If the pillar dimensions or the hinge position do not allow the in-

stallation of the actuator, a niche on the pillar, as shown in Fig. 5, 

should be created in order to maintain the A dimension as deter-

mined. The niche should be dimensioned in such a way to enable 

easy installation, actuator rotation and operation of the release de-

vice. The mounting brackets are designed to enable small adjust-

ments in both directions (fig.5A). In any case, always refer to the 

measurements shown in the table.

Please  keep  to  the  values  given  in  the  table  and  oil  the  gate’s 

hinges.

1_  Fix the rear bracket in the position determined before. In the 

event  of  iron  pillar  carefully  use  n°4  Ø  6,3  mm  self-drilling 

screw (fig.6). In the event of brick pillar (fig.7), use n°4 M8 bolts 

(after you have assembled it, fig.7A).

During  the  fastening  operations,  check  if  the  bracket  is 

perfectly horizontal by means of a level.

WARNING  -    In  case  of  large  gate  leaves  and  /or 

closed design leaves other than the installation of 

an electro lock it is suggested to strengthen the fas-

tening of the back bracket (weld the steel parts in-

stead of using screws to assemble the bracket, use 

M10 instead of M8 screws, weld the bracket onto the 

pillar, etc.).

ENGLISH

Summary of Contents for ARM2000ENC

Page 1: ...Uso Residenziale Condominiale Swing Gate Operator Residential Communities Drehtorantrieb für Privat und Gewerbe Automatisme pour Portails à Battant Usage Résidentiel Intensif Accionador para Puertas Batientes Uso Residencial Comunidades Via Enrico Fermi 43 36066 Sandrigo VI Italia Tel 39 0444 750190 Fax 39 0444 750376 info tauitalia com www tauitalia com IT Istruzioni originali D_MNL0ARM2000 08 11...

Page 2: ...book will be corrected in the next edition When opening the packing please check that the product is intact Please recycle materials in compliance with current regulations This product may only be installed by a qualified fitter The manufacturer declines all liability for damage to property and or personal injury deriving from the incorrect installation of the system or its non compliance with cur...

Page 3: ...a cancello completamente aperto Y L Utente utilizzatore deve astenersi da qualsiasi tentativo di riparazione o d intervento diretto e rivolgersi solo a personale qualificato Z Tutto quello che non è previsto espressamente in queste istruzioni non è permesso Consigliamo di riporre tutta la documentazione relativa all impianto all interno o nelle immediate vicinanze della centralina Italiano IMPORTA...

Page 4: ...r der Installation genau lesen da sie wichtige Hinweise mit Bezug auf Sicherheit Installation Bedienung und Wartung liefern Eine falsche Installation oder ein fehlerhafter Betrieb des Produktes können zu schwerwiegenden Personenschäden führen B Das Verpackungsmaterial Kunststoff Styropor usw sollte nicht in Reichweite von Kindern aufbewahrt werden da es eine potentielle Gefahrenquelle darstellt C ...

Page 5: ...ón dispone de un dispositivo de seguridad antiaplastamiento constituido por un control de par No obstante es necesario comprobar el umbral de intervención según lo previsto en las Normas indicadas en el punto I O Los dispositivos de seguridad norma EN 12978 permiten proteger posibles áreas de peligro de Riesgos mecánicos de movimiento como por ej aplastamiento arrastre corte P Para cada equipo se ...

Page 6: ...Arbeitzzyklus Cycle de travail Ciclo de trabajo 100 36 Tempo corsa 90 90 travel time Laufzeit 90 Temps de course 90 Tiempo recorrido 90 12 sec 20 sec NOTA QUANDO IL SISTEMA IN 12 VDC È ALIMENTATO UNICAMENTE DALLA BATTERIA IN CASO DI BLACK OUT OPPURE IN ABBINAMENTO CON PANNELLO FOTOVOLTAICO LE PRESTAZIONI ESPRESSE DAL MOTORIDUTTORE FORZA E VELOCITÀ SI RIDUCONO DEL 30 CA N B WHEN THE SYSTEM IS IN TH...

Page 7: ...allare l automazione apportare tutte le modifiche strutturali relative alla realizzazione dei franchi di sicurezza ed alla protezione o segregazione di tutte le zone di schiacciamento ce soiamento convogliamento e di pericolo in genere Verificare che la struttura esistente abbia i necessari criteri di robustezza e stabilità gli elementi costruttivi meccanici devono essere in accordo con quanto sta...

Page 8: ...ci in apertura 1 fig 9B ed in chiu sura 2 fig 9B nella posizione che consenta di aprire l an ta dell angolo desiderato Per accedere ai grani di fissaggio degli arresti meccanici 3 fig 9B è necessario movimentare manualmente l attuatore vedi par SBLOCCO MANUALE Verificare l esattezza della regolazione tramite una manovra manuale con attuatore sbloccato ed eventualmente correg gere Nota future regol...

Page 9: ...a descritta RUMOROSITÀ Il rumore aereo prodotto dal motoriduttore in condizioni normali di utilizzo è costante e non supera i 70 dB MESSA IN FUNZIONE ATTENZIONE Prima di effettuare qualsiasi inter vento sull impianto o sull attuatore togliere l ali mentazione elettrica Seguire scrupolosamente i punti I J K L ed M degli OBBLIGHI GENERALI PER LA SICUREZZA Seguendo lo schema di fig 3 e la relativa ta...

Page 10: ...chine 2006 42 CE Dichiara inoltre che questo prodotto è conforme ai requisiti essenziali di sicurezza delle seguenti ulteriori direttive CEE 2006 95 CE Direttiva Bassa Tensione 2004 108 CE Direttiva Compatibilità Elettromagnetica ed ove richiesto alla Direttiva 1999 5 CE Apparecchiature Radio e apparecchiature terminali di telecomunicazione Dichiara inoltre che non è consentito mettere in servizio...

Page 11: ...and ards EN 12604 and EN 12605 leaf length in compliance with the actuator specifications regular and uniform movement of the leaves without any fric tion and dragging during their entire travel stiff hinges in good conditions presence of both opening and closing mechanical limit stops presence of an efficient earthing for electrical connection of the actuator Perform any necessary metalwork job b...

Page 12: ...s 3 fig 9B incise the endless screw compromising the correct sliding of the fork 12_ When a gate operator with electric limit switch is used ARM2000F or ARM2000FC proceed as follows ARM2000F nominal rod stroke is 350 mm to adjust stroke loosen the locking nuts 1 pict 9C and set the limit switch to the required position Max adjustment is 50 mm Once the adjustment is completed tighten the locking nu...

Page 13: ...needs by following the given instructions TESTING THE AUTOMATED SYSTEM Carefully check operating efficiency of the automated system and of all accessories connected to it paying special attention to the safety devices Hand the User Guide to the final user together with the Main tenance register Explain correct operation and use of the automated system to the user Indicate the potentially dangerous...

Page 14: ...es that this product complies with the essential safety requirements of the following EEC directives 2006 95 EC Low Voltage Directive 2004 108 EC Electromagnetic Compatibility Directive and where required with the Directive 1999 5 CE Radio equipment and telecommunications terminal equipment Also declares that it is not permitted to start up the machine until the machine in which it is incorporated...

Page 15: ...lmente come prima dell installazione Manutenzione per durare nel tempo e funzionare in completa sicurezza come qualsiasi altro macchinario l impianto necessita di una periodica manutenzione Stabilite insieme al vostro installatore i tempi di tale manutenzione Tau consiglia un intervento ogni 6 mesi per un normale uso domestico che può variare in funzione dell intensità d uso sempre ogni 3000 cicli...

Page 16: ...r disconnect the system from the power supply immediately and perform the manual release operation see figure Do not attempt to repair the door but call in your fitter the system will operate manually as it did before installation Maintenance to ensure long life and totally safe operation the system required routine maintenance just like any other piece of machinery Establish maintenance times toget...

Page 17: ...ie Ihren Installateur nach dem Entriegeln wird die Anlage von Hand funktionieren wie vor der Installation Wartung um zu dauern und ganz sicher zu funktionieren bedarf die Anlage wie jede andere Maschine einer periodischen Wartung Legen Sie die Wartungszeiten zusammen mit Ihrem Installateur fest Tau empfiehlt für den normalen Hausgebrauch eine Wartung alle 6 Monate was je nach Gebrauchshäufigkeit unt...

Page 18: ...nstallateur une fois débloquée l installation fonctionnera manuellement comme avant l automatisation Maintenance pour durer dans le temps et fonctionner en toute sécurité comme toute autre machine l installation a besoin d une maintenance périodique Établissez avec votre installateur un plan de maintenance Tau conseille une intervention tous les 6 mois pour un usage domestique normal qui peut vari...

Page 19: ...NGS ZEICHNEN PROJETS DIBUJOS 99 907 3 350 122 5 1 2 6 5 3 4 1 a 2 7 4 4 1 a b f c c d d e 7 3 7 3 5 6 7 8 9 10 ARM2000 ARM2000ENC a 4x1 5 mm 2x2 5 mm 3x0 5 mm b 3x1 5 mm 3x1 5 mm c 2x0 5 mm 2x0 5 mm d 4x0 5 mm 4x0 5 mm e 3x0 5 mm 3x0 5 mm f 2x1 mm 1RG58 2x1 mm 1RG58 ...

Page 20: ...16 ARM2000 Series fig 5 C A X B fig 7 fig 8 fig 6 1 fig 5A fig 4 fig 7A ARM2000 Series DISEGNI DRAWINGS ZEICHNEN PROJETS DIBUJOS C 805 mm ARM2000 ARM2000F C 775 mm ARM2000FC ...

Page 21: ...M2000 Series ARM2000 Series DISEGNI DRAWINGS ZEICHNEN PROJETS DIBUJOS 1 mm fig 10 1 2 fig 9B fig 9D fig 12 fig 9A 2 1 3 3 3 3 fig 11 fig 9C max 50 mm 350 mm max 50 mm max 50 mm 340 mm ARM2000F ARM2000FC 1 1 ...

Page 22: ...n Chiude Close Zu Ferme Cierra Apre Open Auf Ouvre Abre Negativo encoder Encoder negative Minuspol Encoder Négatif encoder Negativo encoder Negativo encoder Positivo encoder Encoder positive Pluspol Encoder Positif encoder Positivo encoder Positivo encoder Segnale encoder Encoder signal Encodersignal Signal encodeur Señal encoder Sinal encoder Negativo motore Motor negative Minuspol Motor Négatif ...

Page 23: ...sbloqueada la instalación funcionará manualmente como antes de montar la automatización Mantenimiento para garantizar una larga vida útil y para un funcionamiento seguro la instalación al igual que cualquier otra maquinaria requiere un mantenimiento periódico Establezca con su instalador las frecuencias de dicho mantenimiento Tau aconseja realizar un mantenimiento cada 6 meses para un uso residenc...

Page 24: ... clutch Connections and operation of safety devices Connection and efficiency of earth socket Anschluss und Funktionstüchtigkeit des Differentialschalters Einstellung und Funktionstüchtigkeit der elktronischen Kupplung Anschlüss und Funktionstüchtigkeit der Sicherheitsvorrichtungen Anschlüss und Funktionstüchtigkeit der Erdung Connexion et efficacité de l interrupteur différentiel Etalonnage et fonc...

Page 25: ... device Operation of limit switches if any Connections and operation of accessories Gearmotor fixing condition Funktionstüchtigkeit der manuellen Freigabevorrichtung Funktionstüchtigkeit der eventuellen endschalter Anschlüss und Funktionstüchtigkeit der Zubehörs Befestigung des Getriebes Fonctionnement du dispositif de déblocage manuel Fonctionnement des fins de course éventuels Connexion et fonctio...

Page 26: ... Fastening pins conditions Wear of front rear fitting Gate general conditions Fitter s signature User s signature Zustand der Befestigungsstifte Verschleiß des Anschlusses vorne hinten Allgemeiner Zustand des Tors Unterschrift des Wartungsmannes Unterschrift des Benutzers Conditions des axes de fixation Usure de la patte d attache antérieure postérieure Conditions générales du portail Signature répa...

Page 27: ... und die Leis tungskabel von den Steuerkabeln getrennt gehalten werden Vorabprüfungen Vor der Installation der Automatisierung alle strukturellen Ände rungen für das Vorhandensein der Sicherheitsabstände und den Schutz aller Bereiche ausführen in denen Quetsch Schnitt und Mitnehmgefahr und Gefahren allgemein bestehen Prüfen ob die vorhandene Struktur die erforderliche Robust heit und Stabilität be...

Page 28: ...rau ben benutzen die Beschläge am Pfosten schwei ßen usw 2_ Den Antrieb nach der Abnahme des Klemmleistendeckels mit der mitgelieferten Schraube und der entsprechenden Mutter am hinteren Bügel befestigen siehe 1 Abb 8 ACHTUNG Sollte der Antriebskopf bei geschlosse nem Tor die Halterung berühren siehe Abb 8 ist die Einstellung nicht korrekt 3_ Prüfen ob sich der vordere Anschluss 1 Abb 9A in der in...

Page 29: ...omversorgung abschalten bevor das Steuergehäuse und oder der Getriebemotor geöffnet werden nicht am Stromkabel ziehen um den Stecker zu ziehen den Motor nicht berühren wenn Sie sich nicht sicher sind dass er abgekühlt ist das Gittertor nur in Bewegung setzen wenn es vollständig sichtbar ist außerhalb des Aktionsbereichs des Tors bleiben wenn es sich bewegt warten bis keine Bewegung mehr erfolgt Ki...

Page 30: ... dieses Produkt den grundsätzlichen Sicherheitseigenschaften der folgenden Richtlinien EWG entspricht 2006 95 EG Niederspannungsrichtlinie 2004 108 EG Richtlinie für elektromagnetische Kompatibilität Und wo gefordert der Richtlinie 1999 5 CE Radio equipment and telecommunications terminal equipment Außerdem wird erklärt dass es nicht zugelassen ist die Vorrichtung in Betrieb zu setzen bis die Masc...

Page 31: ...nde Vérifications préliminaires Avant d installer l automatisme apporter toutes les modifications structurelles relatives à la réalisation des espaces de sécurité et à la protection ou à l isolement de toutes les zones d écrasement cisaillement et de danger en général Vérifier que la structure existante possède la robustesse et la stabilité nécessaires les composants mécaniques doivent répondre au...

Page 32: ... fermeture 2 fig 9B dans la position permettant d ouvrir le vantail avec l angle désiré Pour accéder aux goujons de fixation des bu tées mécaniques 3 fig 9B il faut manœuvrer manuellement le vérin voir par DÉBRAYAGE MANUEL Vérifier l exacti tude du réglage en effectuant une manœuvre manuelle avec le vérin débrayé et corriger éventuellement Notes les prochains réglages à fin d augmenter la course d...

Page 33: ...as tirer le cordon d alimentation pour débrancher la prise de courant ne pas toucher le moteur si l on n est pas sûr qu il est refroidi mettre en mouvement le portail seulement quand il est complè tement visible rester hors du rayon d action du portail tant qu il est en mouve ment attendre qu il soit complètement arrêté ne pas laisser les enfants ou les animaux jouer à proximité du portail ne pas ...

Page 34: ... Déclare d autre part que ce produit est conforme aux exigences essentielles de sécurité des directives CEE suivantes 2006 95 CE Directive Basse Tension 2004 108 CE Directive Compatibilité Électromagnétique et si requis à la Directive 1999 5 CE Équipements hertziens et équipements terminaux de télécommunication Le Fabricant déclare également qu il n est pas permis de mettre en service l appareil t...

Page 35: ...lar la automatización realice todas las modificacio nes estructurales relativas a la realización de las distancias de seguridad y a la protección o separación de todas las zonas de aplastamiento corte y peligro en general Controle que la estructura existente posea los criterios necesa rios de robustez y estabilidad Los elementos constructivos mecánicos deben estar de acuer do con lo establecido en...

Page 36: ...paradas mecánicas en apertura 1 fig 9B y en cierre 2 fig 9B en la posición que permita abrir la hoja hasta el ángulo deseado Para acceder a los bulones de centraje de fijación de las paradas mecánicas 3 fig 9B es necesario mover manualmente el actuador véase apartado DESBLOQUEO MANUAL Compruebe la correcta regulación mediante una maniobra manual con el actuador desbloqueado y eventual mente efectú...

Page 37: ...abrir la caja de mandos o el accionador No tirar del cable de alimentación para desconectar la clavija No tocar el motor si no está seguro de que se haya enfriado completamente Accionar la cancela sólo cuando esté completamente a la vis ta Mantenerse fuera del radio de acción de la cancela si ésta se está moviendo esperar a que se haya detenido No dejar que niños o animales jueguen cerca de la can...

Page 38: ...ue este producto cumple con los requisitos esenciales de seguridad de las siguientes ulteriores directivas CEE 2006 95 CE Directiva Baja Tensión 2004 108 CE Directiva Compatibilidad Electromagnética y donde es necesario con los de la Directiva 1999 5 CE Equipos radioeléctricos y equipos terminales de telecomunicación Declara además que no está permitido poner en servicio la maquinaria hasta que la...

Page 39: ...negratuita francosedeTAU spesediimballoeditrasportosonoacaricodelcliente dellepartichepresentanodifettidilavorazioneovizidimaterialericonosciuti dallaTAU Incasodiinterventoadomicilio anchenelperiodocopertodagaranzia l utenteètenutoacorrispondereil Dirittofissodichiamata perspeseditrasferimentoadomicilio piùmanodopera La garanzia decade nei seguenti casi Qualorailguastosiadeterminatodaunimpiantonon...

Page 40: ... la ley sobre la privacidad 675 96 y modificaciones sucesivas Os dados pessoais do usuário serão utilizados pela garantia e para Enviar material informativo Os dados serão tratados de modo informatizado segundo o art 13 Lei 675 96 e suas sucessivas modificações Doc cod D CGR0TAU00 Garantie TAU conditions générales FRANÇAIS LagarantieTAUauneduréede24moisà compterdeladated achatdesproduits ledocumen...

Reviews: