background image

 
 
 
 

 
 

Rev. D 

2017-07-25 

RMM_00042 

 

FCC

 

Tattile herewith declares that this product is in compliance with the following US Federal 
Regulation: 

FCC 47 CFR Part 15  (Emission Class B) 

Contains FCC ID: QOQWF111 

This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: 
(1) this device may not cause harmful interference, and (2) this device must accept any interference 
received, including interference that may cause undesired operation. 

This equipment complies with FCC radiation exposure limits set forth for an uncontrolled environment. 
End users must follow the specific operating instructions for satisfying RF exposure compliance. This 
transmitter must not be co-located or operating in conjunction with any other antenna or transmitter. This 
transmitter is considered as mobile device and should not be used closer than 20 cm from a human 
body.

 

Summary of Contents for F01750

Page 1: ...Reference Manual ENG BASIC Automatic Number Plate Recognition Tattile S r l Via G Donizetti 1 25030 Mairano Brescia Italy Ph 39 030 97 000 Fax 39 030 97 001 http www tattile com...

Page 2: ...nge without notice The content of this document is property of Tattile S r l This document and its parts must not be reproduced or copied without written permission from Tattile S r l and the content...

Page 3: ...1 Camera body 12 5 CONNECTIONS 13 5 1 Connector Layout 13 5 2 Power supply Signal and I O Connector 13 5 3 Gigabit PoE Ethernet Socket 14 5 4 Cabling the device 15 6 ACCESSORIES 17 6 1 Pole Mounting...

Page 4: ...ier must be isolated from EARTH Using External 24Vdc power supply Min Typ Max Power supply voltage 24 10 24 24 10 V DC Total power consumption 12 W Imaging and Illumination Monochrome models F01750 F0...

Page 5: ...tal optoisolated PNP input 2 Relay NO output 1 Strobe output Temperature and humidity sensor 3 axis inclinometer Current consumption sensor Real Time Clock Mechanical characteristics Size 178 x 90 x 1...

Page 6: ...al specifications reference below have been applied Art 3 1a Specifiche di Sicurezza Art 3 1a Safety specifications EN 60950 1 2006 A11 2009 A1 2010 A12 2011 AC 2011 A2 2013 Safety IT equipment Art 3...

Page 7: ...interference and 2 this device must accept any interference received including interference that may cause undesired operation This equipment complies with FCC radiation exposure limits set forth for...

Page 8: ...IR illuminator lens 36 wavelength 860nm 15nm spectral bandwidth 50 of max intensity Hazard Ultraviolet hazard 200 400 nm Es Euva Retinal blue light hazard 300 400 nm Lb Retinal blue light or thermal h...

Page 9: ...led as detailed in the figure below at distance L HD there is no risk to the public Operator or maintenance staff working in front of the camera facing the illuminator at distance less than HD must us...

Page 10: ...5 10 RMM_00042 3 Interfaces characteristics Digital input Type Optoisolated PNP Channels 2 Voltage 24 V DC Relay output Type Normally open Channels 2 Max switching voltage 21 V AC 30 V DC Max switchin...

Page 11: ...Rev D 2017 07 25 11 RMM_00042 OUT1 COM OUT1 NO V IN Strobe output Type Optoisolated open collector Channels 1 Max voltage 24 V DC 10 Min voltage 3 3 V DC 10 Max current 50 mA...

Page 12: ...Rev D 2017 07 25 12 RMM_00042 4 Mechanical dimensions 4 1 Camera body Ref Description 1 Lens 2 IR Illuminator 3 Extruded body 4 Cover 5 Cable Glands...

Page 13: ...trobe Output ground 7 IN1 Digital input 1 positive 8 WD0 Wiegand communication D0 9 IN1 Digital input 1 negative 10 WD1 Wiegand communication D1 11 IN0 Digital input 0 positive 12 SER A RS485 serial p...

Page 14: ...thernet Socket RJ45 Gigabit connector Mating connector RJ45 PLUG included Pin Gigabit mode 1000base T 10 100 mode 10base T 100base TX 1 MX1 TX 2 MX1 TX 3 MX2 RX 4 MX3 5 MX3 6 MX2 RX 7 MX4 8 MX4 LED1 L...

Page 15: ...llen screws placed on the left side of the camera 2 Remove the left cover being careful not to break the gasket 3 Open the cable glands and insert the power signals and Ethernet cables through them 4...

Page 16: ...Connect the cables to the device Make sure you place and correctly bend the cable inside the compartment to prevent it from being damaged when closing the left cover 6 Appropriately tighten the cable...

Page 17: ...tor Drawing Ordering Code Note T19841 Pole Mounting Adaptor for poles with diameter between 65mm and 110mm 6 2 Mating Parts Kit Ordering Code Note T19687 Mating parts kit included in the package 6 3 P...

Page 18: ...escription 1 Tattile logo 2 Product Part Number 3 Product Name 4 Product Serial Number 5 Serial Number Barcode code 128 6 Ethernet Mac Address 7 Mac Address Barcode code 128 8 Revision 9 CE mark 10 Ra...

Page 19: ...ve the power supply voltage from the camera before unplugging the power connector Turn off all electrical power before making or breaking any electrical connections to avoid damaging the device Use a...

Page 20: ...P Forti I Paderno Pre C 2017 03 31 General revision of the document R Marchioni I Paderno Pre D 2017 07 25 Revision document and update scheme update Conformity Compliance and added warning IR radiat...