Specifications
For Safety Use!
Caution labels
Precautions
□Carry out installation or wiring following the method instructed in the operation manual.
□Conduct maintenance and periodic inspection following the method instructed in the operation manual.
□Confirm the rated voltage and supply voltage before installing the machine.
□Never soak it in water! Avoid installing the detector in any location subject to high temperature and high humidity.
□When assembling to the machine for use, don’t install in any locations easily accessible to the general public.
□Avoid using the detector in any location subject to excessively dusty environment.
□Avoid using the detector in any location close to sources of vibration, organic gas or strong electromagnetic induction.
□When performing maintenance on this detector, don’t use solvents such as alcohol, toluene and diluents, etc.
□Do not conduct disassembling or reconstruction to the detector.
□ Do not use the sensor as electric wire!
□ Please contact us in case of any failure.
①
Customer Consultation
Shanghai Representative Office :Room B28/F, Huadu Mansion, No.838 Zhang Yang Road, Pudong, Shanghai
ZIP 200122
Tatsuta Electric Wire & Cable Co., Ltd.
Tel
:
0086-21-5058-5177
Fax
:
0086-21-5058-5199
Headquarter:
〒
578-8585
Tokyo Branch:
〒
210-0015
2-3-1, Iwata-cho, Higashi-Osaka City, Osaka Prefecture
3rd floor, Nihon-Seimei Kawasaki Bldg., 1-1, Minami-machi,
Kawasaki Ward, Kawasaki City, Kanagawa Prefecture
Tatsuta Electric Wire & Cable Co., Ltd.
Tatsuta Electric Wire & Cable Co., Ltd.
System Electronics Division
System Electronics Division
System Department, System Division
Sales Department, System Division
Tel
:
0081-6-6721-3335 Fax
:
0081-6-6725-0018
Tel
:
0081-044-221-7691 Fax
:
0081-44-221-7695
No.1BM-1004-01
Item
Specification
Power source
AC100V~240V (for 50Hz/60Hz)
Allowed scope AC85V~264V (for 50Hz/60Hz)
Sensor electrode voltage
AC5.3V (maximum)
Water leakage detection le
vel
Switchable 3 segments ±30% FOR L: 5KΩ, M: 10KΩ and H: 14KΩ respectively.
Break detection level
30KΩ (for L
,
M and H)
Power consumption
3VA or less
Indicator LED
Dual purpose for power source/water leakage and break alarm
(lighting up once when water leakage happens and lighting up twice when break take
s place)
Non-voltage contact
1 group for water leakage 1c and break 1a respectively
Rated loa
d
Resistive load
Inductive load
AC 250V 6.0A
AC 250V 3.0A
DC 24V 6.0A
DC 24V 2.0A
Caution
■To avoid the occurrence of malfunction!
*Do not touch this detector with wet hands
*Do not insert foreign matters into the detector fromthe gaps
*When carrying out maintenance and periodic inspection
to the
detector, follow the
instructions of the person
in charge of
operation or
the operation manual.
Caution label
Erroneous operation of this water leakage detector not complying with the warning
labels or the
following warnings may not only lead to possible fatality or serious
injury, but also fire, electric shock or detector failure may occur.
Before using, please be sure to read the precautions and the operation manual carefully