VERTICAL TOWED MIXER - ONE AUGER
VN & V SERIES
Tatoma Ag Equipments Corp. Located in Colcord, OK. Phone (918) 422-4271
- 70 -
To change the oil in the auger reductor, follow the next steps:
1. To empty the reductor, first take a container to collect the used oil (capacity ± 5.5 US
Gallons). Disconnect the drain hose (Ld) and the fill hose (Le), place them in the
container and empty the oil of the redactor completely.
2. To fill the reductor connect the filler hose (Le) to an oil pumping system.
3. Introduce oil under pressure through the filling hose (Le) until clean oil starts to come
out without the presence of air bubbles through the drain hose (Ld), provide a clean
container to collect the oil coming from the drain hose.
4. Connect the drain (Ld) and fill (Le) hoses to the tank (D) each in its corresponding
position.
5. Once the hoses are connected, introduce oil into the tank up to the level sight glass
(V).
6. Run the mixer for a few minutes and verify the absence of noise.
7. Stop the mixer and recheck the oil level. Fill if necessary up to the level sight glass (V).
2-speed Gearbox (optional)
To check the oil level there is a sight glass (V)
located on the front of the gearbox.
If the level is low, it must be refilled through the
filling hole (L).
To drain the oil there is a plug (T) at the bottom of
the gearbox.
L
T
V