General safety instructions

Please read the following safety precautions carefully before putting this device to use to avoid
any personal injuries, damage to the instrument, or to the target system. Use this instrument
only for its intended purpose as specified by this manual to prevent potential hazards.

Use included power cord and power supply

The enclosed power supply has been approved for use by iSYSTEM. Please contact iSYSTEM if
you need to consider an alternative power.

Use grounding wire

Prior to applying power to either the BlueBox or the target, connect the device and the target sys-
tem together with the included grounding wire. This is to avoid potential damage caused by any
voltage difference between the device and the target system.

Use proper overvoltage protection

Ensure proper protection to avoid exposing the BlueBox device or the operator to overvoltage
surges (e.g. caused by thunderstorm, mains power).

Do not operate without cover

Do not operate the device with cover removed.

Avoid circuit and wire exposure

Do not touch exposed components or wires when the device is powered.

Do not operate with suspected damage

If you suspect damage may have occurred, the BlueBox device must be inspected by qualified
service personnel before further operation.

Do not operate the device outside its rated supply voltage or environmental
range

Consult with iSYSTEM before using equipment outside of the parameters provided in this
manual.

This symbol is used within the manual to highlight further safety notices. 

Summary of Contents for iSYSTEM CoreSight

Page 1: ...CoreSight Galvanic Isolation Adapter Hardware User Manual V1 3 November 2023 isystem com start...

Page 2: ...otential damage caused by any voltage difference between the device and the target system Use proper overvoltage protection Ensure proper protection to avoid exposing the BlueBox device or the operato...

Page 3: ...Contents Introduction 4 Package content 5 Specifications 6 Device overview 7 Connecting procedure 10 Accessories 11...

Page 4: ...ltages it is mandatory to have a second protection measure in place in case the first insulation barrier fails This is termed double or reinforced isolation How should a double isolation be implemente...

Page 5: ...vanic Isolation Adapter is delivered with the following compon ents CoreSight 20 pin 1 27 mm Galvanic Isolation Adapter USB PD Power supply Ribbon cable Ordering code IEA GI CORESIGHT Ordering code IT...

Page 6: ...ORM 560 V peak DEBUG TOOL SIDE Supply Voltage 5 V via attached power supply Max Supply Current 50 mA TARGET SIDE Supply Voltage 3 V 5 V via VREF Max Supply Current 50mA PERFORMANCE JTAG Up to 50 MHz S...

Page 7: ...supply socket PWR Use only original USB PD Power supply for powering and connecting with the GI Ad apter otherwise the primary functionality of the GI Adapter would be counteracted E Debug interface...

Page 8: ......

Page 9: ...0 pin 1 27 mm CoreSight Debug Adapter The following pinout is valid on the target side Signal Direc tion Signal Descrip tion Signal Pin Pin Signal Signal Descrip tion Signal Direc tion I Reference Vol...

Page 10: ...the BlueBox Refer to the BlueBox User Manual for more details on connecting the Debug Adapter 4 Connect the Debug Adapter to the GI Adapter 5 Connect 1 1 Ribbon cable which is delivered along this pac...

Page 11: ...Accessories Ordering Code Description IC57000 iC5700 BlueBox IC50118 2 20 pin 1 27 mm CoreSight Debug Adapter More information about our products on www isystem com or via sales isystem com...

Page 12: ...www isystem com Visit our website for Support isystem com support Tutorials isystem com start Knowledge Base kb isystem com...

Reviews: