Void Line / White Band
2. Horizontal white streaks (Image sample 1)
If 1.2mm interval horizontal streaks occur at
the gray image in the main scanning
direction, take the following measure. *In
case of this appearance at the machine’s
rear side is more noticeable than at front.
a. Replace the LSU.
Image sample 1
About
1.2mm
Machine
Front
Machine
Rear
8
Summary of Contents for 3500i
Page 48: ...The film attached procedure J49XX J50XX J51XX J600X 3 9 48...
Page 52: ...Replacement procedure for the bushing J49XX J50XX J51XX J600X 7 9 52...
Page 57: ...The film attached procedure J6100 J6110 DF 3 6 57...
Page 71: ...The film attached procedure Corner Folding 3 6 71...
Page 73: ...Corner Folding 5 6 73...
Page 74: ...Corner Folding 6 6 74...
Page 103: ...Abnormal sound from the fuser section 3 5 For 3500i 4500i 5500i 103...