Measure for condensation
<Phenomenon>
Flowing image occurs at printing after power on if the inside machine is in cold condition. (condensation
image occurs)
<Method of measure>
1.Update the firmware above Pack.3.07
2.Change refresh frequency (mode) of U148
3.If the condensation occurs easily depends on installation environment (the temperature difference in the
morning and day time is too large and high humidity), set mode 2 in U148.
4.Set to Mode 3 if the condensation can not be eliminated at mode 2.
* Caution
Refresh frequency will be increased if increment of mode number. Therefore, if it is pointed out that the
warm up period becomes longer, set to mode 1.
However, the effectiveness of this measures decreases in comparison with Mode2 in the case of set
Mode1, please ask the user understand to perform refresh operation manually at the time of the
condensation occurs.
Mode
Inner humidity <70%
70%
≦
Inner humidity <80%
80%
≦
Inner humidity <90%
90%
≦
Inner humidity
0
0 time
0time
0time
0time
1
0
1
2
3
2
0
2
3
4
3
0
4
5
6
⇒
Recomm
ended
Refresh frequency in each mode
26
Summary of Contents for 3500i
Page 48: ...The film attached procedure J49XX J50XX J51XX J600X 3 9 48...
Page 52: ...Replacement procedure for the bushing J49XX J50XX J51XX J600X 7 9 52...
Page 57: ...The film attached procedure J6100 J6110 DF 3 6 57...
Page 71: ...The film attached procedure Corner Folding 3 6 71...
Page 73: ...Corner Folding 5 6 73...
Page 74: ...Corner Folding 6 6 74...
Page 103: ...Abnormal sound from the fuser section 3 5 For 3500i 4500i 5500i 103...
Page 104: ...Abnormal sound from the fuser section 4 5 For 3500i 4500i 5500i 104...