background image

= 75 PSI ULTIMATIC

= 75 PSI ULTIMATIC

= 100 PSI ULTIMATIC

= 100 PSI ULTIMATIC

ULTIMATIC 125 Flow Chart

ULTIMATIC 125 Flow Chart

150 ft.

150 ft.

150 ft.

150 ft.

150 ft.

150 ft.

200 ft.

200 ft.

200 ft.

200 ft.

200 ft.

200 ft.

250 ft.

250 ft.

250 ft.

250 ft.

250 ft.

250 ft.

125

350

600

300

500

250

450

225

400

200

175

150

PUMP

DISCHARGE

PRES

SURE

(PSI)

PUMP

DISCHARGE

PRES

SURE

(PSI)

3/4" HOSE

1" HOSE

1 1/2" HOSE

100 PSI

100 PSI

100 PSI

100 PSI

100 PSI

100 PSI

100 PSI

100 PSI

100 PSI

75 PSI

75 PSI

75 PSI

75 PSI

75 PSI

75 PSI

75 PSI

75 PSI

75 PSI

10

16

20

23

26

29

34

38

42

46

49

55

13

17

20

22

25

29

33

36

39

42

48

11

15

18

20

22

26

29

32

34

37

42

23

34

42

50

56

62

72

80

90

98

105

120

20

29

36

42

48

52

62

70

78

84

90

100

18

26

32

38

42

46

54

62

68

74

80

90

70

60

50

100

125

85

110

125

75

95

110

125

22

25

27

30

32

34

38

42

45

52

57

49

19

21

24

26

28

30

33

37

39

42

45

50

17

19

21

23

25

27

30

33

35

38

40

44

53

61

68

75

82

88

99

109

117

47

54

60

66

71

77

86

95

103

110

117

42

49

55

60

65

69

78

85

93

99

106

117

108

125

89

106

118

97

114

(1) Number in each box indicates flow (GPM). (2) Flows may vary with brand or condition of hose.
(3) Flows are approximate and do not reflect losses in preconnect piping.

(1) Number in each box indicates flow (GPM). (2) Flows may vary with brand or condition of hose.
(3) Flows are approximate and do not reflect losses in preconnect piping.

FLOW (GPM)

75 PSI

100 PSI

= 7 BAR ULTIMATIC

= 7 BAR ULTIMATIC

ULTIMATIC 125 Flow Chart

ULTIMATIC 125 Flow Chart

45M

45M.

45M

60M

60M

60M

75M

75M

75M

8.6

24

41

21

34

17

31

15.5

28

14

12

10

PUMP

DISCHARGE

PRES

SURE

(BAR)

PUMP

DISCHARGE

PRES

SURE

(BAR)

19mm HOSE

25mm HOSE

38mm HOSE

7 BAR

7 BAR

6 BAR

(1) Number in each box indicates flow (LPM). (2) Flows may vary with brand or condition of hose.
(3) Flows are approximate and do not reflect losses in preconnect piping. (4) 1 BAR = 100 KPA

(1) Number in each box indicates flow (LPM). (2) Flows may vary with brand or condition of hose.
(3) Flows are approximate and do not reflect losses in preconnect piping. (4) 1 BAR = 100 KPA

FLOW (LPM)

= 6 BAR ULTIMATIC

= 6 BAR ULTIMATIC

6 BAR

7 BAR

40

60

75

85

100

110

130

145

160

175

185

210

85

95

100

115

120

130

145

160

170

185

195

215

----

50

65

75

85

95

110

125

135

150

160

180

70

80

90

100

105

115

125

140

150

160

170

190

----

40

55

70

75

85

100

110

120

130

140

160

65

70

80

85

95

100

115

125

130

145

150

165

7 BAR

6 BAR

6 BAR

7 BAR

7 BAR

7 BAR

7 BAR

7 BAR

7 BAR

6 BAR

6 BAR

6 BAR

6 BAR

6 BAR

6 BAR

75

110

135

160

180

195

235

265

295

320

340

380

180

205

225

250

270

290

325

360

390

415

445

----

85

130

160

190

210

235

275

305

340

370

395

455

200

230

255

285

310

335

375

415

445

----

----

----

70

100

120

145

160

175

205

235

255

280

305

340

160

185

210

225

245

260

295

320

350

375

400

445

265

380

475

----

----

----

----

----

----

----

----

----

410

475

----

----

----

----

----

----

----

----

----

----

225

320

415

475

----

----

----

----

----

----

----

----

365

430

----

----

----

----

----

----

----

----

----

----

190

285

360

415

475

----

----

----

----

----

----

----

335

400

445

----

----

----

----

----

----

----

----

----

9

9.0 NOZZLE FLOW CHARTS

LIN-030 November 14, 2008 Rev 10

©Copyright Task Force Tips, Inc. 2002-2008

Summary of Contents for Ultimatic

Page 1: ...on manual is intended to familiarize firefighters and maintenance personnel with the operation servicing and safety procedures associated with the Ultimatic Mid Matic and Handline fire fighting nozzle...

Page 2: ...r or moderate injury 2 The member companies of FEMSA that provide emergency response equipment and services want responders to know and understand the following 1 Firefighting and Emergency Response a...

Page 3: ...g pattern control from straight stream to wide fog Power fog teeth for full fill fog Gasket grabber inlet screen to keep large debris from entering nozzle Easily flushable while flowing to clear trapp...

Page 4: ...p Line Orange Preconnect or discharge 2 Red Preconnect or discharge 3 Yellow Preconnect or discharge 4 White Preconnect or discharge 5 Blue Preconnect or discharge 6 Black Preconnect or discharge 7 Gr...

Page 5: ...ing can occur If nozzle gets out of control or away from operator retreat from nozzle immediately Do not attempt to regain control of nozzle while flowing water 4 0 NOZZLE CONTROLS On models that use...

Page 6: ...ing the STREAM SHAPER clockwise as seen from the operating position behind the nozzle moves the SHAPER to the straight stream position Turning the SHAPER counterclockwise will result in an increasingl...

Page 7: ...hat fails inspection is dangerous to use and must be repaired before using Performance tests shall be conducted on the Ultimatic Mid Matic and Handline nozzle after a repair or anytime a problem is re...

Page 8: ...o is an intended or unintended beneficiary of the equipment shall not be entitled to recover from TFT any consequential or incidental damages for injury to person and or property resulting from any de...

Page 9: ...es in preconnect piping FLOW GPM 75 PSI 100 PSI 7 BAR ULTIMATIC 7 BAR ULTIMATIC ULTIMATIC 125 Flow Chart ULTIMATIC 125 Flow Chart 45M 45M 45M 60M 60M 60M 75M 75M 75M 8 6 24 41 21 34 17 31 15 5 28 14 1...

Page 10: ...55 80 179 69 218 112 194 100 215 91 Flow Nozzle Reaction Chart Flow Nozzle Reaction Chart MID MATIC Flow Nozzle Reaction Chart Flow Nozzle Reaction Chart MID MATIC 7 BAR 7 BAR 7 BAR 7 BAR 7 BAR 7 BAR...

Page 11: ...in each box indicates flow LPM and number on bottom indicates nozzle reaction KG 2 Flows may vary with brand or condition of hose 3 Flows are approximate and do not reflect losses in preconnect pipin...

Page 12: ...e and nozzle reaction Shaper turns freely and adjusts pattern through full range Shaper turns into full flush and out of flush with normal flow and pressure restored 10 0 INSPECTION CHECKLIST Any Ulti...