background image

©Copyright Task Force Tips LLC  2011-2019 

LIG-012 March 28, 2019 Rev06

24

#

DESCRIPTION

QTY PART #

7

3/16" SS BALL

34

V2120

8

O-RING-032

1

VO-032

9

NFTS ADAPTER

1

G602

10

VALVE BODY

1

G600

TIP ONLY BASE

G601

11

O-RING-222

2

VO-222

12

SLIDER

1

G605

13

VALVE PLUG SUBASSEMBLY

1

G903

14

PORT PLUG

1

B770

15

DISK

2

G615

16

3/8-16 X 5/16 SOCKET SET SCREW

1

VT37-16SS312

17

O-RING-011

3

VO-011

18

HANDLE COVER, BLACK 

2

HM625

19

8-14 X 3/8 PUSHTITE BUTTON HEAD

4

VT08-14PT375

20

VALVE HANDLE

1

G620

21

CAM PIN

2

G616

22

HANDLE SCREW

2

HM645

23

DETENT SPRING

2

HM770

24

.243" TORLON BALL

2

VB243TO

25

1/8" ACETAL BALL

56

VB125AC

26

GRIP SPACER F100

1

HM693-F

27

PISTOL GRIP, BLACK 

1

HM692-BLK

28

WASHER

1

VM4901

29

3/8-16 X 1 SOCKET HEAD SCREW

1

VT37-16SH1.0

30

INDEX RING LABEL G-FORCE 100 PSI      AUTOMATIC       

1

G641A0L

INDEX RING LABEL G-FORCE 100 PSI W/FM      AUTOMATIC       

G641A0L-FM

INDEX RING LABEL G-FORCE 75 PSI      AUTOMATIC       

G641A1L

INDEX RING LABEL - G-FORCE      AUTO 6 BAR, PULSING 250, AUTO, LOW       

G641A2L

INDEX RING LABEL - G-FORCE      AUTO 5 BAR PULSING 200 AUTO LOW       

G641A2L-01

INDEX RING LABEL - G-FORCE      AUTO 100 PSI PULSING 60-150 LOW       

G641A2L-03

INDEX RING LABEL - G-FORCE      AUTO 125 PSI PULSING 90-155 LOW       

G641A2L-04

INDEX RING LABEL - G-FORCE      AUTO 6 BAR, 500 LPM       

G641A2LB

INDEX RING LABEL - G-FORCE      AUTO 6 BAR, PULSING 235, AUTO, LOW       

G641A3L

INDEX RING LABEL - G-FORCE      AUTO 6 BAR, 400 LPM       

G641A3LB

INDEX RING LABEL - G-FORCE      AUTO 6 BAR, PULSING 500 LPM, LOW       

G641A4L

INDEX RING LABEL - G-FORCE      AUTO 6 BAR, PULSING 50/100/150 LPM, LOW       

G641L0L

INDEX RING LABEL - G-FORCE      AUTO 6 BAR, PULSING 50/100/150 LPM       

G641L0LB

INDEX RING LABEL - G-FORCE      AUTO 6 BAR, PULSING 150, AUTO 250       

G641L0LC

INDEX RING LABEL - G-FORCE 40 BAR      AUTO 6 BAR, PULSING 150, AUTO 250       

G641L0LC40

INDEX RING LABEL - G-FORCE      AUTO 75 PSI 60-150 GPM, NO AUTO (150 I.O       

G641L10L

INDEX RING LABEL - G-FORCE, METRIC      AUTO 5 BAR 240-570 LPM, NO AUTO (570 I.O       

G641L10LM

INDEX RING LABEL - G-FORCE      AUTO 6 BAR, PULSING 150 LPM, LOW       

G641L11L

INDEX RING LABEL - G-FORCE 40 BAR      AUTO 6 BAR, PULSING 150 LPM, LOW       

G641L11L40

INDEX RING LABEL - G-FORCE, METRIC L/SEC      AUTO 7 BAR 1.7-6 LPS, 6-9.5 LPS, NO AUTO       

G641L13LM

INDEX RING LABEL - G-FORCE, RUSSIAN      AUTO 7 BAR 2-6, 6-10. 10 LITERS PER SEC       

G641L13LM-RU

INDEX RING LABEL - G-FORCE      AUTO 6 BAR, 250/500 LPM, LOW       

G641L1L

INDEX RING LABEL - G-FORCE      AUTO 6 BAR, 250/500 LPM       

G641L1LB

INDEX RING LABEL - G-FORCE      AUTO 6 BAR, PULSING 100, 250/500 LPM, LO       

G641L2L

INDEX RING LABEL - G-FORCE      AUTO 6 BAR, PULSING 250, 500 LPM       

G641L2LB

INDEX RING LABEL - G-FORCE      AUTO 75 PSI, PULSING 65, 130 GPM       

G641L2LB-CN

INDEX RING LABEL - G-FORCE      AUTO 6 BAR, 235/400 LPM, LOW       

G641L3L

INDEX RING LABEL - G-FORCE      AUTO 6 BAR, 235/400 LPM       

G641L3LB

INDEX RING LABEL - G-FORCE      AUTO 6 BAR, PULSING 400 LPM, LOW       

G641L4L

INDEX RING LABEL - G-FORCE      AUTO 6 BAR, PULSING 235, 400 LPM       

G641L4LB

INDEX RING LABEL - G-FORCE      AUTO 100 PSI, 30-95, 95-150 GPM       

G641L5L

INDEX RING LABEL - G-FORCE, METRIC      AUTO 7 BAR 100-360, 360-570 LPM       

G641L5LM

INDEX RING LABEL - G-FORCE      AUTO 75 PSI 30-100, 90-150 GPM       

G641L6L

INDEX RING LABEL - G-FORCE, METRIC      AUTO 5 BAR 100-390, 330-570 LPM       

G641L6LM

INDEX RING LABEL - G-FORCE      AUTO 100 PSI 30-70, 70-110, 110-150 GPM       

G641L7L

INDEX RING LABEL - G-FORCE, METRIC      AUTO 7 BAR 100-270, 270-430, 430-570 LPM       

G641L7LM

INDEX RING LABEL - G-FORCE, METRIC W/FM      AUTO 7 BAR 100-270, 270-430, 430-570 LPM       

G641L7LM-FM

INDEX RING LABEL - G-FORCE      AUTO 75 PSI 30-80, 60-110,110-150 GPM       

G641L8L

INDEX RING LABEL - G-FORCE, METRIC      AUTO 5 BAR 100-300, 240-420, 420-570 LPM       

G641L8LM

INDEX RING LABEL - G-FORCE      AUTO 100 PSI 60-150 GPM, NO AUTO (150 I.       

G641L9L

INDEX RING LABEL - G-FORCE, METRIC      AUTO 7 BAR 250-570 LPM, NO AUTO (570 I.O       

G641L9LM

INDEX RING LABEL - G-FORCE, METRIC W/FM      AUTO 7 BAR 250-570 LPM, NO AUTO (570 I.O       

G641L9LM-FM

INDEX RING LABEL - G-FORCE, METRIC L/SEC      AUTO 7 BAR 4.2-9.5 LPS, LOW (9.5 I.O.)       

G641L9LMS

Summary of Contents for G-Force G A Series

Page 1: ...g proper training is a misuse of this equipment Obtain safety information at tft com serial number This Instruction Manual is intended to familiarize re ghters and maintenance personnel with the opera...

Page 2: ...IMPULSE TRIGGER VALVE LUBRICATION 11 3 SERVICE TESTING 11 2 1 HYDROSTATIC TESTING 11 2 2 FLOW TESTING 11 2 3 RECORDS 11 4 REPAIR 12 0 WARRANTY 13 0 OPERATION AND INSPECTION CHECKLIST DANGER PERSONAL R...

Page 3: ...ted by quali ed personnel before being considered safe for use WARNING This equipment is intended for use by trained personnel for re ghting Their use for other purposes may involve hazards not addres...

Page 4: ...GRIP DETENTS VARIOUS COUPLINGS AVAILABLE VARIOUS COUPLINGS AVAILABLE FLOW CONTROL OFF ON 4 POSITION LOCK NOZZLE WITH IMPULSE TRIGGER VALVE SYSTEM TACTILE INDICATOR OR SHAPER LOCK STREAM SHAPER Figure...

Page 5: ...75 PSI 230 110 360 570 470 l min 500 kPa 5 bar FIXED GALLONAGE SELECTABLE GALLONAGE A B C D E E 0 20 40 60 80 100 120 140 0 20 40 60 80 100 120 140 160 180 200 220 Flow gpm Pressure psi 0 1 2 3 4 5 6...

Page 6: ...230 l min 700 kPa 7 bar 110 E F A B C D E A B C D E GD A FIXED GALLONAGE SELECTABLE GALLONAGE GD C GD F GD H Figure 4 2C 1 0 25 mm G Force 100 psi 7 bar Fixed and Selectable Nozzles 0 50 100 150 200 2...

Page 7: ...40 60 80 100 120 140 160 180 200 220 Flow gpm Pressure psi 0 1 2 3 4 5 6 7 8 9 0 100 200 300 400 500 600 700 800 Flow LPM Pressure BAR AUTOMATIC FLUSH G F Figure 4 3B 1 5 38 mm G Force 75 psi 5 bar A...

Page 8: ...B 60 150 GPM 100 PSI AUTO AUTOMATIC 250 570 l min 700 kPa 7 bar AUTO AUTOMATIC A B A B G G G R 95 150 GPM 100 PSI 30 95 360 570 l min 700 kPa 7 bar 100 360 A B A B G H G S 0 100 200 300 400 500 600 7...

Page 9: ...150 GPM 75 PSI 30 100 A B 330 570 l min 500 kPa 5 bar 100 390 A B 0 100 200 300 400 500 600 700 800 0 1 2 3 4 5 6 7 8 9 0 20 40 60 80 100 120 140 0 20 40 60 80 100 120 140 160 180 200 220 Flow LPM Pr...

Page 10: ...AUTOMATIC 20 80 gpm 100 psi AUTO B A AUTOMATIC 75 300 l min 7 bar B A AUTO GD U GD W Figure 4 4C 1 0 25 mm G Force 100 psi 7 bar Automatic with Flow Limiting 0 50 100 150 200 250 300 350 400 450 500...

Page 11: ...ide 100 19 8 3 250 34 13 6 500 41 17 9 Reach meters 0 100 200 300 400 500 600 700 800 0 1 2 3 4 5 6 7 8 9 10 Flow l min Pressure bar GP B 100 l min 235 l min 400 l min l min Flow Straight Narrow Wide...

Page 12: ...ow Pm Range l min Flow Straight Narrow Wide 250 34 13 6 500 41 17 9 Reach meters 0 100 200 300 400 500 600 700 800 0 1 2 3 4 5 6 7 8 9 10 Flow l min Pressure bar GP G Pulsing 235 Auto 400 Low Pm Range...

Page 13: ...100 200 300 400 500 600 700 800 0 1 2 3 4 5 6 7 8 9 10 Flow l min Pressure bar GP N Pulsing 235 Auto 400 Pm Range l min Flow Straight Narrow Wide 235 33 13 6 400 40 16 8 Reach meters 0 100 200 300 400...

Page 14: ...0 0 1 2 3 4 5 6 7 8 9 10 Flow l min Pressure bar GP W 100 l min 235 l min l min Flow Straight Narrow Wide 100 19 8 3 235 33 13 6 Reach meters l min Flow Straight Narrow Wide 100 19 8 3 200 28 11 5 300...

Page 15: ...ers 0 1 2 3 4 5 6 7 8 9 10 0 50 100 150 200 250 300 350 Pressure bar Flow l min GDP E 235 l min 150 l min 100 l min 40 l min PN 16 models only l min Flow Straight Narrow Wide 40 11 5 2 100 18 8 3 150...

Page 16: ...8 9 10 0 100 200 300 400 500 600 Pressure bar Flow l min GDP N Auto 400 Pm Range l min Flow Straight Narrow Wide 300 34 13 7 Reach meters 0 1 2 3 4 5 6 7 8 9 10 0 100 200 300 400 500 600 Pressure bar...

Page 17: ...les have NO shut o valve within the nozzle and MUST be used with a separate ball valve attached to the nozzle 5 1 3 BALL SHUT OFF Some models include either an integrated ball valve or a separate ball...

Page 18: ...usting the closing speed and always verify performance after adjustment 5 1 5 NORMAL OPERATING POSITION 45 15 90 45 Horizontal Slow Closer Operating Range Slow Closer Operating Range WARNING The Slow...

Page 19: ...ote Turning the shaper further forward will cause stream crossover and reduce the e ective reach of the nozzle The nozzle reaction is greatest when the shaper is in the straight stream position The no...

Page 20: ...otate the shaper guide to obtain the desired stream pattern 4 Tighten the clamp ring with a pin spanner 5 Apply a new shaper label Figure 5 2 4 Stream Pattern Adjustment 5 3 FLUSH CONTROL Small debris...

Page 21: ...en release of built up pressure in the hose when opening a nozzle 6 1 FOAM ASPIRATING ATTACHMENTS To increase the expansion ratio G Force Series MX Foamjet multi expansion attachment or LX Foamjet low...

Page 22: ...connect or discharge 5 Preconnect or discharge 6 Preconnect or discharge 7 Foam Lines Orange Red Yellow White Blue Black Green Red w White border Red White Other Colors Available Gray Pink Purple Tan...

Page 23: ...0 22 28 29 26 27 58 45 50 51 52 53 54 55 45 46 47 48 49 43 37 35 34 32 31 36 33 39 40 38 44 42 56 63 64 65 66 61 62 59 60 57 56 30 8 56 DESCRIPTION QTY PART 1 GASKET 1 5 1 V3130 2 COUPLING 1 5 BSPF ST...

Page 24: ...O G641L10L INDEX RING LABEL G FORCE METRIC AUTO 5 BAR 240 570 LPM NO AUTO 570 I O G641L10LM INDEX RING LABEL G FORCE AUTO 6 BAR PULSING 150 LPM LOW G641L11L INDEX RING LABEL G FORCE 40 BAR AUTO 6 BAR...

Page 25: ...32 INDEX RING 30 60 95 125 150 GPM 100 PSI 1 G641 suffix is engraved on raised lug 33 CLAMP RING 1 G656 34 CLAMP RING LABEL G FORCE BLUE 1 G656L B CLAMP RING LABEL G FORCE GREY G656L G CLAMP RING LABE...

Page 26: ...5 F N A G690 SWIVEL 2 5 BIC MALE N A G694 3 GASKET GRABBER 1 B730 G606 4 VO RING 1 VO 127 VO 134 5 LABEL TOP 1 TN600LT TN600LT 6 LABEL LEFT 1 TN600LL TN600LL 7 VALVE BODY 1 TN600G10 TN600G15 8 QUAD R...

Page 27: ...R PULSING 250 500 LPM G641L2LB G641L2LB INDEX RING LABEL G FORCE AUTO 75 PSI PULSING 65 130 GPM G641L2LB CN G641L2LB CN INDEX RING LABEL G FORCE AUTO 6 BAR 235 400 LPM LOW G641L3L G641L3L INDEX RING L...

Page 28: ...624 29 BARREL SHAPER LOCK OUT 1 G627 G627 30 BARREL LABEL G FORCE BLUE 1 G625L B G625L B BARREL LABEL G FORCE GRAY G625L G G625L G BARREL LABEL G FORCE BLACK G625L K G625L K 31 QUAD RING 225 1 VOQ 422...

Page 29: ...9 20 22 23 24 25 21 6 5 1 7 8 9 26 28 29 30 31 A 32 27 6 5 51 52 53 54 55 57 57 56 56 56 47 48 16 49 50 42 43 41 44 45 40 33 9 34 36 37 35 38 39 46 66 67 11 10 62 65 63 59 60 58 1 64 5 6 61 68 69 70 2...

Page 30: ...AR PN40 GD642DP40L INDEX RING LABEL ONE INCH G FORCE 40 100 150 235 L MIN 6 BAR GD642EP16L INDEX RING LABEL ONE INCH G FORCE 100 150 235 LPM 6 BAR PN40 GD642EP40L INDEX RING LABEL ONE INCH G FORCE 100...

Page 31: ...IXED METAL TEETH BUMPER SUBASSEMBLY 1 GD954 SPINNING TEETH BUMPER SUBASSEMBLY GD952 SHAPER WITH RUBBER TEETH BUMPER GD650 57 FIXED AND SELECTABLE BAFFLE SUBASSEMBLY 1 GD930 FIX SELECTABLE BAFFLE SUBAS...

Page 32: ...tion of Break Free CLP will be needed on a regular basis CAUTION Aerosol lubricants contain solvents that can swell O Rings if applied in excess The swelling can inhibit smooth operation of the moving...

Page 33: ...elp keep excess BreakFree from the outside of the nozzle 3 Keep nozzle upside down for at least 10 seconds to allow the BreakFree to ow into the valve area 4 Check for smooth and free operation of the...

Page 34: ...king binding or other problems 4 Evaluate the ow of nozzles as de ned by NFPA 1964 in the following manner Basic Spray Nozzles shall ow no less than and no more than 10 percent over the rated ow at th...

Page 35: ...ibutable to TFT To qualify for this limited warranty the claimant must return the equipment to TFT at 3701 Innovation Way Valparaiso Indiana 46383 9327 USA within a reasonable time after discovery of...

Page 36: ...EING PLACED BACK IN SERVICE nozzles must be inspected to this checklist 1 All controls and adjustments are operational 2 Shut o valve if so equipped closes o the ow completely 3 There are no broken or...

Reviews: