Monitoring tables
Monitoring tables
DA-88 and DA-38
PLAY
REC
STOP, FF.
REW
JOG/
SHUTTLE
ALL INPUT
on
Source
ALL INPUT
off
AUTO MON
off
REC FUNCTION
on
REC FUNCTION
off
Tape
Tape
Mute
Tape
AUTO MON
on
REC FUNCTION
on
Tape
Source
Source
See below
REC FUNCTION
off
Tape
Tape
Mute
DA-88 and DA-38 shuttle modes (ALL INPUT off, AUTO MON on)
JOG/SHUTTLE
JOG/ SHTL MON
off
Tape
JOG/SHTL MON
on
REC FUNCTION
on Source
REC FUNCTION
off Mute
DA-98
PLAY
REC
STOP, FF.
REW
JOG/
SHUTTLE
ALL INPUT
on
Source
ALL INPUT
off
AUTO MON
off
REC FUNCTION
on
Selectable
a
a. “Selectable” means that confidence mode can be used here
Source
Selectable
Selectable
b
b. When the shuttle mute function is active (see 8.6.2 in the DA-98 manual), output is muted in these modes
REC FUNCTION
off
Selectable
b
AUTO MON
on
REC FUNCTION
on
Tape
Source
Source
See below
bc
c. When shuttle monitoring is turned off here, monitoring is off-tape, and when it is turned on, the input source is monitored
REC FUNCTION
off
Selectable
b