−5−
3. Test Mode
テストモード
TASCAM MD-CD1 & LA-MC1
3-1. How to set the test mode enabled
While holding down the OPEN/CLOSE and EJECT keys, switch on
the power.
(You need to keep both keys held down until the display reads
"Test Mode".)
To turn the test mode off, switch off the power.
3-2. Test mode menu
When running in test mode, the center encoder is available for
selecting test items and confirming your selection.
The following items are available:
[DISPLAY CHK]
[KEY CHECK]
[ENCODER CHK]
[CONT SW CHK][
KEYBOARD CHK]
[RS-232C CHK]
[EEP CHECK]
[MD ADJUST]
This procedure is applicable for MD-CD system
microcomputer version 1.10 and above.
[VERSION UP]
[VERSION CHK]
When an item is selected and you press the CD STOP key, you
will go back to the test mode menu.
3-3. Test items explained
1) DISPLAY CHK
With each press of the DISPLAY key, the FL display tube shows
grids and characters as shown below, with LEDs being on or off:
To turn off this selection, press the CD STOP key.
1st stage: FL display tube and all LEDs turned off
2nd stage:
3-1.テストモードへの入り方
「OPEN/CLOSE」と「EJECT」キーを押しながら電源を投
入する。
(ディスプレイに「Test Mode」と表示するまで押し続ける)
テストモードは電源OFFで終了する。
3-2.テストモードメニュー
テストモードに入ったら、センターエンコーダでテスト項目
を選択、決定する。
選択項目は以下の通りである。
「DISPLAY CHK」
「KEY CHECK」
「ENCODER CHK」
「CONT SW CHK」
「KEYBOARD CHK」
「RS-232C CHK」
「EEP CHECK」
「MD ADJUST」
本手順は、MD-CD1 システムマイコン Ver.1.10
以降に適用されます。
「VERSION UP」
「VERSION CHK」
選択状態でCD側「STOP」キーを押すことで選択項目に戻
る。
3-3.各テストモードの説明
1)DISPLAY CHK
「DISPLAY」キーを押す毎に、下記の様にFL管にGRID、キ
ャラクター部を表示し、LEDが点灯もしくは消灯する。
「CD STOP」キーにてテストモード終了する。
第1段階はFL管消灯、LED全消灯。
第2段階
3rd stage:
4th stage:
第3段階
第4段階