Tascam HS-4000 New Features Manual Download Page 8

X

HS-4000

TASCAM HS-4000

Network functions (FTP/telnet/VNC) added

FTP (file transfer protocol) 

By using an FTP client application, you can transfer files between this unit 

and a computer. 
Connect to this unit and login in the same way as with other FTP servers. 

After connecting and logging in, “A:” and “B:” will appear in the root directory. 

These correspond to the unit's CF1 and CF2 slots. If the corresponding slot 

does not contain a card, the “A:” or “B:” will appear empty. 

NOTE

 

i

To display Japanese, use an FTP application that supports Unicode. 

 

i

Always set the maximum number of simultaneous transfers of the FTP client 

application to "1". If not set to "1" files cannot be transferred properly. 

 

i

For information about FTP client applications that have been confirmed to work 

properly with this unit, please contact TASCAM customer support. 

 

0

Required settings for connecting by FTP 
The following settings are necessary for connecting to this unit by FTP. 
IP address:   This unit's IP address is shown in the 

IP Address

 field of 

the 

REMOTE SETUP

 screen 

ETHERNET

 page. 

Port: 

 

  21

User name:   HS-4000 (cannot be changed, case sensitive)
Password:   HS-4000 (default, case sensitive)
 

 

 

 

 This setting can be changed by using the 

Password

 

Change

 button on the 

REMOTE SETUP

 screen 

ETHERNET

 

page. 

NOTE

 

i

The number of simultaneous connections is "1". Depending on the FTP client 

application, two simultaneous connections with this unit might be possible, but 

files might not be transferred correctly, so we recommend that you do not use 

two or more simultaneous FTP connections with this unit. 

 

i

FTP connections cannot be made when EXTERNAL Control has been set to LOCK 

on the Lock Setup screen. Likewise, setting this to LOCK will end any active FTP 

connection.

 

i

Changing any settings on the REMOTE SETUP screen of the ETHERNET page will 

also end any active FTP connection. 

 

0

Working with files using an FTP client application 
1.  Read files from the unit

You can read files from this unit at any time. 

2.  Add new files to the unit

You can add files to this unit at any time. 
When recording, if you add BWF or WAV files to the current session, 

they will be shown in the list with existing files, recorded files and 

added files in that order. 

3.  Overwrite existing files on the unit

You can only overwrite the current take when the unit is stopped. You 

can overwrite other files at any time. See “Important precautions re-

garding overwriting files” below.

4.  Delete a file on the unit

The current take can be deleted only when the unit is stopped. Files 

other than the current take can be deleted at any time. See “Precau-

tions when deleting files on the unit” below.

5.  Add a new folder to this unit

You can add a new folder to this unit at any time.

6.  Delete a folder from this unit

You can only delete the current folder when stopped. 
You can delete any folder other than the current from this unit at any 

time. 

7.  Edit the names of files/folders on this unit

You cannot edit the names of files/folders on this unit. 

CAUTION 

If you work with files/folders by FTP during recording, you will not be able to 

retake (erasing the last recorded region/take).

Important precautions regarding overwriting files

You cannot overwrite the take that is in use on the playlist mode 

ADJUST

 

screen. You can overwrite other files on this unit at any time. 
However, when the 

PLAY SETUP

 screen 

GENERAL

 page 

Play Mode

 setting is 

All Take

, you might not be able to overwrite the take following the current 

take depending on the timing. 

Precaution in playlist mode 

In playlist mode, if you overwrite a take that has been added to a playlist as 

an entry, a “?” will be shown for the corresponding entry on the 

ENTRY

 and 

file 

ASSIGN

 screens, and that file will be ignored for playback. 

To enable playback of a file that has overwritten another, add the overwrit-

ten file as an entry.

Precautions in on air mode

 

i

In on air mode, if you overwrite a file shown in the on air list screen, the 

corresponding take will be unchecked and the file will be ignored for 

playback. 

 

i

When the following rebuild confirmation message is shown, touch 

OK

When you rebuild all the takes will be enabled for playback (checked), so 

deselect any that you do not want to be played back.

Precaution when overwriting files with different properties 

If overwriting causes the size, number of channels, bit-rate or sampling 

frequency of an audio file to be different from the previous file, inconsisten-

cies could occur in the existing timeline or playlist. If such an inconsistency 

occurs, the following error message will appear when you start playback. 

Conduct the following to eliminate the inconsistency and stop the error mes-

sage from occurring. 

 

i

Timeline mode:  Erase the affected region. 

 

i

Take mode:    

Delete the affected take from the CF card.

 

i

Playlist mode:    Add the overwritten file as an entry. 

 

i

On air mode:   

 Use the Home Screen pull-down menu 

REBUILD

 

button. 

CAUTION 

Do not overwrite an existing audio file with a file that uses a different sampling 

frequency. The inconformity that results could become unresolvable. 

Precautions when deleting files on the unit

The current take can be deleted only when the unit is stopped. Files other 

than the current take can be deleted at any time. 
Deleting files will cause inconsistencies between the system files and audio 

files, so it is necessary to rebuild after deleting a file. 
After deleting a file (and stopping if another file has been playing back or 

recording), the following rebuild confirmation message will appear. Touch 

OK

 

to rebuild. 

Summary of Contents for HS-4000

Page 1: ...the time display mode is T C you can now locate manually based on the timecode time in take and playlist modes Take name resets when new project session created When a new project session is created...

Page 2: ...nd then touch the ADJUST ENTRY button in the pull down menu to open the ADJUST XXX screen XXX is the entry number NOTE You can also open this by touching the MENU button and then touching the ADJUST b...

Page 3: ...hange assignments on the right side Change the BC STANDBY END range in one operation A new function allows you to change the BC STANDBY BC END mark range in one operation 1 In playlist mode open the p...

Page 4: ...buttons on the left side to check uncheck files Checked files will be used for on air playback Remove a check mark making the box grey to deselect the file for on air playback 5 Touch a file name butt...

Page 5: ...the transport jumps to the BC STANDBY mark of the next take and playback continues If the next take does not have a BC STANDBY mark playback will continue without jumping NOTE i i This setting can on...

Page 6: ...e the Last Setting or Factory Preset settings will not be reloaded The next time the unit is started the Last Setting or Factory Preset settings will be loaded Auto Marker PRE REC END ON OFF setting O...

Page 7: ...e show the current values of these settings When IP SETUP is set to STATIC use these field to set the values Default values 0 0 0 0 Depending on the IP SETUP setting this area appears differently as s...

Page 8: ...this unit You can add a new folder to this unit at any time 6 Delete a folder from this unit You can only delete the current folder when stopped You can delete any folder other than the current from...

Page 9: ...Changing any settings on the REMOTE SETUP screen of the ETHERNET page will also end any active Telnet connection i i For information about this unit s RS 232C command protocol please contact TASCAM c...

Page 10: ...is CF card does not meet the speci fications required by the system so normal recording playback operations cannot be guaranteed n 1 or 2 New popup messages in HS 4000 V1 21 Message Details and respon...

Page 11: ...ading factory presets PLEASE CONFIRM Load User Preset Reconfirm loading user preset settings PLEASE CONFIRM Reset ALL Start End Point Confirm resetting the starting and ending times of all entries to...

Page 12: ...X HS 4000 12 TASCAM HS 4000 Printed in China...