Tascam HS-4000 New Features Manual Download Page 10

X

HS-4000

10 

TASCAM HS-4000

 

0

Necessary setting for VNC connections 
The following settings are necessary for connecting to this unit using a 
VNC viewer application. 
IP address:   This unit’s IP address is shown in the 

IP Address

 field of 

the 

REMOTE SETUP

 screen 

ETHERNET

 page. 

Password:   HS-4000 (default, case sensitive)
 

 

 

 

 This setting can be changed by using the 

Password

 

Change

 button on the 

REMOTE SETUP

 screen 

ETHERNET

 

page. 

NOTE

 

i

2 or more simultaneous VNC connections are not possible. 

 

i

When EXTERNAL Control has been set to LOCK on the Lock Setup screen, display  

is possible but operation is not when using a VNC viewer application. 

 

i

Changing any settings on the REMOTE SETUP screen of the ETHERNET page will 

also end any active VNC connection. 

 

i

For information about VNC viewer application that have been confirmed to work 

properly with this unit, please contact TASCAM customer support. 

 

i

When files are being transferred by FTP or when the system sampling frequency is 

88.2 or 96 kHz, VNC viewer application display and operation will not be smooth. 

Changed pop-up messages 

Old message 

New message 

Details and responses

Remarks 

CFn not recommended format for 

Recording/Playing.

When media loaded: 

CFn formatting not optimal for 

Recording/Search.

When starting recording: 

CFn formatting not optimal 

for Recording.

Since the media was not formatted by 

this unit, normal recording and search 

operations cannot be guaranteed. 

Format the media with this unit before 

use. 

n = 1 or 2

This appears when the card is format-

ted with a cluster size that is smaller 

than the standard of this unit.

CFn not recommended for 

Recording/Playing.

(not UltraDMA) 

When media loaded: 

CFn not recommended type 

for Recording/Search.

(not UltraDMA) 

This CF card does not meet the speci-

fications required by the system, so 

normal recording/playback operations 

cannot be guaranteed.

n = 1 or 2

New popup messages in HS-4000 V1.21 

Message 

Details and responses

Remarks 

Cannot Change Now 

Currently ON AIR

Changes cannot be made when on air. 

Cannot Copy. 

Destination Project is 

different Fs.

The copy destination sampling frequency is different so copying 

is not possible. 

Cannot Copy.

Selected Take already exist

in Copy destination.

The selected take already exists in the copy destination so  

copying is not possible. 

Cannot set Mark point 

in ON AIR Mode.

Marks cannot be set when in on air mode. 

Cannot use Bridge file 

because it is illegal.

The bridge file is not formatted correctly, and could not be 

understood.

Capture BC$ Time to ALL?

BC$STANDBY    -> Start

BC$END 

   -> 

End

Confirm changing all entries to the BC$STANDBY/BC$END mark 

time range. 

Capture BC$ Time?

BC$STANDBY    -> Start

BC$END 

   -> 

End

Confirm changing to the BC$STANDBY/BC$END mark time 

range. 

CFn(vvvvvvvv)

    Fs 

fs

USED   SIZE  : u

FREE    SIZE  : f

TOTAL  SIZE  : t

This shows information about the CF card when in on air mode

n = 1 or 2

vvvvvvvv = volume level

fs: the current sampling frequency setting

u: used capacity

f: unused capacity

t: total capacity of CF card

Change Fs to nnkHz?

Confirm changing the system Fs to the shown sampling  

frequency. 

nn: sampling frequency

Confidence Monitor is not available 

with current Fs/Rec CH settings.

The sampling frequency or recording channel settings prevent 

the use of confidence monitoring. 

Copy n selected Take?

Confirm copying selected take(s). 

n = number of takes

Takes if n is 2 or more

Copying Take...

Take is being copied. 

"Takes..." when multiple takes are being copied

Directory contents changed 

via FTP.

REBUILD required.

REBUILD Now?

The contents of the directory were changed by FTP, so rebuild-

ing is necessary. 

EDL Import completed 

but there are some wrong regions.

EDL importing has completed, but some regions have problems. 

Summary of Contents for HS-4000

Page 1: ...the time display mode is T C you can now locate manually based on the timecode time in take and playlist modes Take name resets when new project session created When a new project session is created...

Page 2: ...nd then touch the ADJUST ENTRY button in the pull down menu to open the ADJUST XXX screen XXX is the entry number NOTE You can also open this by touching the MENU button and then touching the ADJUST b...

Page 3: ...hange assignments on the right side Change the BC STANDBY END range in one operation A new function allows you to change the BC STANDBY BC END mark range in one operation 1 In playlist mode open the p...

Page 4: ...buttons on the left side to check uncheck files Checked files will be used for on air playback Remove a check mark making the box grey to deselect the file for on air playback 5 Touch a file name butt...

Page 5: ...the transport jumps to the BC STANDBY mark of the next take and playback continues If the next take does not have a BC STANDBY mark playback will continue without jumping NOTE i i This setting can on...

Page 6: ...e the Last Setting or Factory Preset settings will not be reloaded The next time the unit is started the Last Setting or Factory Preset settings will be loaded Auto Marker PRE REC END ON OFF setting O...

Page 7: ...e show the current values of these settings When IP SETUP is set to STATIC use these field to set the values Default values 0 0 0 0 Depending on the IP SETUP setting this area appears differently as s...

Page 8: ...this unit You can add a new folder to this unit at any time 6 Delete a folder from this unit You can only delete the current folder when stopped You can delete any folder other than the current from...

Page 9: ...Changing any settings on the REMOTE SETUP screen of the ETHERNET page will also end any active Telnet connection i i For information about this unit s RS 232C command protocol please contact TASCAM c...

Page 10: ...is CF card does not meet the speci fications required by the system so normal recording playback operations cannot be guaranteed n 1 or 2 New popup messages in HS 4000 V1 21 Message Details and respon...

Page 11: ...ading factory presets PLEASE CONFIRM Load User Preset Reconfirm loading user preset settings PLEASE CONFIRM Reset ALL Start End Point Confirm resetting the starting and ending times of all entries to...

Page 12: ...X HS 4000 12 TASCAM HS 4000 Printed in China...

Reviews: