3
MEMORY START PLAY
Unless you are starting from the beginning of a program, you should first
capture a locate point using one of the two MEMO locations.
1) Press MEMORY START - its LED will light solid
2) Press either ID SEARCH ( for beginning of desired program ) or the LOC key
( either 1 or 2 ) that corresponds to the desired memory point
3) Tape will position itself and store audio into the memory buffer during which time
the MEMORY START LED blinks
4) Once the buffer is loaded, the tape repositions to the original cue point and the
MEMORY START LED once again lights solid - the STOP button lights solid while
the PLAY button blinks - the DA-60
MK
II is now in Memory Start Standby mode
Note: The Memory Start function's performance may vary, depending upon the status
of the Auto Cue feature. Screen 12 “iSdFt” and its three possible parameters (oFF,
iS on, iS-cuE on) determines whether only MEMORY START or a combination of
MEMORY START and AUTO CUE is automatically activated each time the unit is
turned on.“Off” is the default parameter. Consult the Owner's Manual for more
information.
MEMORY START POINT TRIM
1)
While in Memory Start Standby mode, press DATA - you will hear an audio loop
approximately 200 msec. in length
2) Rotate DATA DIAL either clockwise or counter clockwise, loop moves forward or
backwards in single frame increments (maximum
±
30 frames from original point)
3) Upon reaching the desired cue point, press SET - to abort function and return to
original point, press RESET
MEMORY START PREVIEW
(Audition Buffered Audio)
1) Press REHEARSAL - function dependent upon Memory Start feature
OFFSET
1)
Press MENU
▲
or
▼
and select "
■
CHASE OFFSET"
2) Press DATA - the "hour" digits of the offset screen will blink and successive
presses of DATA enable you to cycle from "minutes" to "seconds" to "frames" to
"sub frames" and back to "hour"
3) Enter the desired offset using the DATA DIAL and DATA key - upon completion,
press SET
P2 EXTERNAL CONTROL SETUP
1)
Set REMOTE to ON
2) Set CLOCK to VIDEO or WORD
3) Hold SHIFT and press MENU
▲
or
▼
until you arrive at screen display "26 SYncP",
press DATA (current status will blink)
4) Rotate the DATA DIAL to "on" and press SET
5) Hold SHIFT and press MENU
▲
or
▼
until you arrive at screen display "--P2--",
press DATA (current status will blink)
6) Rotate the DATA DIAL to "oPEn" and press SET