A instalação deste produto deverá ser feita por um profissional qualificado.
The installation of this product must be made by a qualified professional.
Page 1: ...A instala o deste produto dever ser feita por um profissional qualificado The installation of this product must be made by a qualified professional...
Page 2: ...sn oautorizadas Danos de qualquer natureza consequentes de problemas no produto bem como perdas causadas pela interrup odouso Defeitosprovocadosporacess rios modifica esouequipamentosacopladosaoprodut...
Page 3: ...lisaas caracter sticas e condi es das mesmas e faz a recarga buscando a melhor performance Se o n vel de carga das bateriasestivercr tico afonteajustaautomaticamenteacorrentedesa da fazendocargasmartd...
Page 4: ...taporumprofissionalqualificado TOMADA A tomada dever ser dimensionada de forma a suportar a corrente m xima consumidapelafonte EXTENS O Opcional n oacompanhaoproduto Comprimentom ximode10metros 127V _...
Page 5: ...edi ria ou m xima Este sistema garante uma maior vida til aos coolers e proporciona um ambiente mais silencioso pois os coolers s entram em opera o em caso denecessidade Obs Caso a fonte seja desligad...
Page 6: ...derecarga Caso o LED esteja piscando lento a bateria foi desconectada ou a sa de da bateria possa estar comprometida LOGOILUMINADO Acendecomafonteligadaeinformaquandoatuaasprote es Recargas de bateria...
Page 7: ...MODO TENS O FIXA poss vel fixar a tens o de sa da da fonte e desabilitar as fun es SMART Paraisso comafontedesligada pressioneateclaSMARTKEYpor15segundos OLEDs da logo mostram a configura o Ap s isso...
Page 8: ...V AC 1300W 2000VA ou 1450W FP 0 60 capacitivo 10A 2 90A 90 18A 3W Bivolt Automatic 127 220VAC 12 0V 14 5V 182 x 52 x 256mm Prote odecurto Desligamomentaneamenteasa dacasoumcurtosejadetectado Prote o t...
Page 9: ...ct The product presents damage resulting from drops impacts or the action of agents of nature floods lightning etc Costs of removal and reinstallation of the equipment as well as its transport to the...
Page 10: ...lation and use of all the benefits this product can offer If there is any question after reading this manual contact our technical support at the phone number 55 18 3266 4050 or through ourwebsitewww...
Page 11: ...nded CircuitBreaker 100A Cable 16mm 5AWG BATTERYCABLES Itisindispensable toinstallacircuitbreakernear thepowersupply AC mains connections IMPORTANT Any connection to the power supply must be made with...
Page 12: ...heir speed according to temperature and output current This system ensures a useful life for the coolers and provides a quieter ambient as the coolers only come into operation only if necessary With t...
Page 13: ...thepowersupply 12 LED indicators protection system LEDs flashing 3x LEDs Flashing 2x LEDs flashing 6x per second and continuously LEDs flashing 1 second on and 1 second off 3x 2x 6x High temperature p...
Page 14: ...the power supply will indicate by the FULL POWER LED and will already have the CAIXA BOB MODE activated The voltagecanbechangedbytheSMARTKEY 12 6V 13 8V 14 4V CAIXABOBMODE Withbattery As soon as it i...
Page 15: ...AC 190 250V AC 90A 90 18A 10A 2000VA or 1450W FP 0 60 capacitive 3W 2 20A 12 0V 14 5V 182 x 52 x 256mm 7 17 x 2 05 x 10 1 1 86Kg 4 09lb ShortProtection Temporarilyshutsofftheoutputifashortcircuitisdet...
Page 16: ...MN_019947_R00 Fabricado por Manufactured by TARAMPS ELECTRONICS LTDA CNPJ TAX ID 11 273 485 0001 03 R Jo o Silv rio 121 Res Manoel Martins Alfredo Marcondes SP Ind stria Brasileira Made in Brazil...