Installation
Recommended wire gauge & fuse
CAUTION: All connections to power supply, input and output connectors must be
carried out only with amplifier off.
Caution: Using wire gauges below the recommendation will result in power loss and
overheating of wiring.
Positive / negative power supply cable ___________________
______________11 AWG
Remote cable ___________________
_________________________________
_
18 AWG
Calculated considering a maximum length of 4m. Distance greater than this, you will
need to increase the cable gauges.
Protection fuse or circuit breaker
_______________________________________
__
20A
It is compulsory to install a protection fuses or circuit breakers as close as possible from
batteries.
Output cables with gauge_______________________________
___________ 15 AWG
Check polarity and never reverse power supply cables due to the risk of damage to the
amplifier.
ENGLISH
11
4 ohms
4 ohms
4 ohms
4 ohms
Note:
In case of horns and tweeters you must install a passive filter in the positive
terminal of the same ones (Consult transducer’s manufacturer manual).
Connection example in the output: Stereo
RCA Cable
Taramps
Head Unit
12V
GND
*Illustrative images
Remote Cable 18 AWG
4mm² (11 AWG)