1. INSTALLATION
IOM manual Tapflo Metal Series
8
1.
INSTALLATION
1.1.
Operation principle
The Tapflo diaphragm pump is driven by compressed air. The two diaphragms are connected
by a diaphragm shaft and pushed back and forth by alternately pressurising the air chambers
behind the diaphragms using an automatically cycling air valve system.
The Suction Cycle:
➢
Suction
One diaphragm creates a suction action in one chamber (on the right) when being pulled
back from the housing.
➢
Discharge
The other diaphragm simultaneously transmits the air pressure to the liquid in the second
chamber (on the left) of the housing, pushing it towards the discharge port.
During each cycle the air pressure on the back of the discharging diaphragm is equal to the
head pressure on the liquid side. Tapflo diaphragm pumps can therefore be operated against
a closed discharge valve with no negative effect to the life of the diaphragms.
1.2.
Receiving inspection
Although precaution is taken by us when packing and shipping, we urge you to carefully check
the shipment on receipt. Make sure that all parts and accessories listed on the packing list are
accounted for. Immediately report any damage or shortage to the transport company and to
us.
Summary of Contents for Metal Series
Page 32: ...5 SPARE PARTS IOM manual Tapflo Metal Series 32 5 1 3 TX70 TX420 Spare parts drawing...
Page 36: ...5 SPARE PARTS IOM manual Tapflo Metal Series 36 5 1 6 TX820 Spare parts drawing...
Page 40: ...5 SPARE PARTS IOM manual Tapflo Metal Series 40 5 2 3 T220 T420 Spare parts drawing...
Page 44: ...5 SPARE PARTS IOM manual Tapflo Metal Series 44 5 2 6 T820 Spare parts drawing...
Page 51: ...6 DATA IOM manual Tapflo Metal Series 51 Dimensions T820 S...
Page 56: ......