background image

Release 08/2007 Ver. 2.0 

 

Technical Manual: C6 Multifunction Interface Controller

  

TAPESWITCH CORPORATION

 

 

Phone: 631-630-0442 

100 Schmitt Boulevard 

6

 

Fax: 631-630-0454 

Farmingdale, New York 1735 

 

www.tapeswitch.com 

M 1 D

M 1 B

M 1 A

M 1 C

+ 2 4

C O M

G 1 A

G 1 B

M 2 D

M 2 B

M 2 A

M 2 C

+ 2 4

C O M

G 2 A

G 2 B

M 3 D

M 3 B

M 3 A

M 3 C

+ 2 4

C O M

G 3 A

G 3 B

M 4 D

M 4 B

M 4 A

M 4 C

M 5 A

M 5 B

M 5 C

M 5 D

M 6 D

M 6 B

M 6 A

M 6 C

C T R

N /C

C T R

N /O

N /C

N /O

C T R

N /C

C T R

N /O

N /C

N /O

C T R

N /C

N /O

C T R

N /C

C T R

N /O

N /C

N /O

C T R

N /C

N /O

+

-

S

a

fe

ty

 O

/P

 1

S

a

fe

ty

 O

/P

 2

M

o

n

ito

r

O

/P

 1

M

o

n

ito

r

O

/P

 2

M

o

n

ito

r

O

/P

 3

M

o

n

ito

r

O

/P

 4

M

o

n

ito

r

O

/P

 5

M

o

n

ito

r

O

/P

 6

M

A

T

 1

G

U

A

R

D

 1

M

A

T

 2

M

A

T

 3

M

A

T

 4

M

A

T

 5

G

U

A

R

D

 2

G

U

A

R

D

 3

R

E

S

E

T

2

4

 V

 D

C

A

U

T

O

/

M

A

N

U

A

L

R

E

S

E

T

P

R

O

G

R

A

M

J

U

M

P

E

R

S

3

5

6

4

2

1

M

A

T

 6

A ll u n u s e d  m a t in p u ts  m u s t b e  lin k e d  o u t
u s in g  ju m p e r w ire s  in  o rd e r fo r th e  c o n tro lle r
to  o p e ra te , i.e .,

L IN K  A -B
L IN K  C -D

If yo u  a re  c o n n e ctin g  a  G u a rd  to  G u a rd  # 1
N O  C O N N E C T IO N S  sh o u ld  b e  m a d e  to  M a t
# 1 .  S a m e  h o ld s tru e  fo r G u a rd  # 2  a n d
G u a rd  # 3 .

C 6  C O N T R O L L E R

C O N N E C T IO N S

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

Figure 5 - PC Board Terminal Block Locations

 

 

Summary of Contents for C6

Page 1: ...they are correctly fitted to a suitable machine It is essential that the full contents of this manual and all the international documents referred to herein are fully understood before any attempt at...

Page 2: ...ork 1735 www tapeswitch com CONTENTS Page 1 INTRODUCTION 3 2 METHODS OF INTERFACING 3 3 ELECTRICAL CONNECTIONS 4 3 1 Reset Manual Automatic 3 2 Pressure Sensitive Sensor s Connections 3 3 Mechanical 3...

Page 3: ...two closed contacts will open when the sensing device is actuated i e safety mat is stepped on or should a fault occur within the safety device or in the event that the power is removed The outputs wi...

Page 4: ...e g as an input to a PLC To protect the contacts of the safety output relays from the effects of switching inductive loads an appropriately rated power factor correction device must be installed for t...

Page 5: ...on Wiring Diagram taking particular care that there are no stray strands which could cause a short between the adjacent terminals A number of sensors can be connected in series See Figure 6 for detail...

Page 6: ...O N C N O CTR N C N O CTR N C CTR N O N C N O CTR N C N O Safety O P 1 Safety O P 2 Monitor O P 1 Monitor O P 2 Monitor O P 3 Monitor O P 4 Monitor O P 5 Monitor O P 6 M AT 1 GUARD 1 MAT 2 M AT 3 MAT...

Page 7: ...ensor 2 Edge sensor N SMOOTH 1 RIBBED 1 SMO RIB C D B A SMOOTH SMOOTH 2 RIBBED RIBBED 2 SMO SMO SMO RIB RIB RIB Edge sensor 1 Edge sensor N Edge sensor 2 INTERCONNECT DIAGRAMS DAISY CHAINED SERIES CON...

Page 8: ...Controller Safety Outputs to Machine Controls Power Input Zone 6 Zone 5 Zone 4 Zone 2 or Sensor 1 Emitter 1 Receiver 1 W1 W2 Zone 1 Sensor 2 or Receiver 2 Emitter 2 W2A W1A Zone 3 Sensor 3 or Emitter...

Page 9: ...W 2 Gray Output 2 5 G1B W 2 Pink Data 6 Isolate 6 7 No Connection W 2 Blue Data 7 Isolate 6 7 No Connection W 2 Shield Ground 8 COM Cable Cable Type Color Code Function From Light Curtain 2 C6 to Guar...

Page 10: ...V DC 2 COM W 1 B Blue Test Out TWIST PAIR TOGETHER Black Blue Wire No Connection W 1 B Black Test In No Connection W 1 B Gray Ground 5 COM RKT8 09 XX Receiver 8 Pin Quick Disconnect W 2 B White OV DC...

Page 11: ...even if the sensors and or light curtain is cleared until the key switch reset is applied 4 Once the reset is applied the flashing red light s for the activated zone s will turn off and the six green...

Page 12: ...C Power Consumption 30VA TYPICAL Enclosure Type Metal Wall Mount Protection Rating NEMA 1 Standard IP10 NEMA 12 Optional IP52 Weight 9 5 lbs 4 3 kg Sensor Wiring Fail Safe Reset Mode Automatic supplie...

Page 13: ...100 Schmitt Blvd Farmingdale NY 11735 Toll Free 1 800 234 8273 Tapeswitch CORPORATION MANUAL MODE OUTPUT OFF OUTPUT ON C 6 M U L T IF U N C T IO N C O N T R O L E R C6 Multifunction Controller C6 10M...

Reviews: