background image

Fig. T 

Fig. U 

7

. Remove the screw (Fig. U) from the side reflector and lift it up away from the heater to remove it. Repeat at 

opposite end to remove other side reflector. 
 
 

8

.  The  lamp  emitter  wires  should  be  pulled  out  of  the  side  slots  and  the  lamp  emitter  can  be  lifted  up        

completely (Fig. V). The wires should be gently pulled so they come out from behind the reflector. 

9

. The lamp emitter should now be removed from the heater as shown in Fig. X. 

 
 

10

.  Refit  the  new  lamp  emitter  in  reverse  order  ensuring  that  no  wires  get  trapped  and  all  screws  are  fully         

tightened.

 

Fig. X 

Fig. V 

10 

Keep the mains supply cord away from the body of the heater which will 
get hot during use. 

 

Arrange the mains supply cord so it cannot be tripped over or damaged. 

 

Do not cover or obstruct the heater while it is in use. 

 

Do not insert any object through any slot or opening in the heater. 

 

Do not use if a guard is not present. 

 

Do not install less than the minimum mounting distance from the floor. 

 

WARNING: 

This heater should only be installed with an energy saving 

device to control the room temperature and operated by users capable 
of  using  the  device.  Do  not  use  this  heater  in  small  rooms  when  they 
are occupied by persons not capable of leaving the room on their own, 
unless constant supervision is provided. 

 

Do not touch the heater when it is turned on, as the body gets hot. 

 

Do  not  use  the  heater  in  a  bathroom,  laundry  areas  and  similar        
locations. Never locate the heater where it may  fall  into  a  bathtub  or 
other water container. 

 

A heater has hot parts inside. Do not use it in areas where petrol, paint, 
or flammable liquids are used or stored. 

 

If  the  supply  cord  becomes  damaged,  it  must  be  replaced  by  the     
manufacturer, its service agent or a similar qualified person in  order to 
avoid a hazard. 

 

WARNING

:  This  appliance  must  be  connected  to  a  supply  that  is 

earthed!

 

 
I M P O R TA N T   -  
S AV E   T H E S E   I N S T R U C T I O N S   F O R   F U T U R E   R E F E R E N C E  

 

 Keep combustible material such as furniture, papers, 
 clothes and curtains at least 1.8m (6ft) away from the 
 sides and rear.

 

W A R N I N G :   R I S K   O F   F I R E

W A R N I N G :   R I S K   O F   F I R E

W A R N I N G :   R I S K   O F   F I R E

W A R N I N G :   R I S K   O F   F I R E  

1.8m 

(6ft) 

Summary of Contents for Sorrento IP Triple

Page 1: ... waste disposal service or the shop where you purchased the product INFORMATION FOR EU MEMBER STATES DECLARATION OF CONFORMITY This product complies with the Harmonised European Standard EN 60335 1 2012 in conjunction with EN 60335 2 30 2009 A11 and EN 62233 and the European Standard Electromagnetic Compatibility EEC Directives 2004 108 EC and 89 336 EEC and the RoHS Directive 2011 65 EU Reference...

Page 2: ... of less than 3 years should be kept away unless continually supervised Children aged from 3 years and less than 8 years shall only switch on off the appliance provided that it has been placed or installed in its intended normal operating position and they have been given supervision or instruction concerning use of the appliance in a safe way and understand the hazards involved Children aged from...

Page 3: ...om the floor WARNING This heater should only be installed with an energy saving device to control the room temperature and operated by users capable of using the device Do not use this heater in small rooms when they are occupied by persons not capable of leaving the room on their own unless constant supervision is provided Do not touch the heater when it is turned on as the body gets hot Do not u...

Page 4: ...178 460 142 16 0 IP55 2 x SOR 215IPT 230 6 x 1 5 9 0 6 5 39 1 5 0 0 5 1 5 1178 460 142 16 0 IP55 2 x SOR 220IPT 230 6 x 2 0 12 0 8 7 52 2 5 0 0 5 1 5 1178 460 142 16 0 IP55 Ingress Protection IP 9 1 Ensure the heater and lamp emitter are cool and the power supply is disconnected by removing the plugs from the socket outlet all plugs must be removed even if only one emitter is to be replaced or dis...

Page 5: ...joined to one or two more units for chain hanging only using joining bars available separately to increase the size and output of the installation Please read the section joining individual heaters together for information on how this should be done INSTALLATION ALL CONFIGURATIONS Warning this appliance must be connected to an earthed supply The wired versions 030IP UK 030IP EU 045IP UK 045IP EU 0...

Page 6: ...SSEMBLING TWO INDIVIDUAL HEATERS JOINED 1 Take the first heater and place it face down on a flat surface 2 Take the second heater and place it face down and positioned parallel to the first heater 3 Push the M8 bolts used to hold the wall brackets through the hole in the brackets on the rear heaters and slide a shake proof washer on all the threads from the protruding side 4 Slide the joining bars...