9
SERIES
6.1
VQ 60 BI-AMP SYSTEM PARAMETERS
y
Parameter
Unit/Name
Low (2x12")
Mid/High
PSW
™
Gain
(dB)
0
-10
Delay
(ms)
0.7
0
Polarity
Positive
Positive
Freq (Hz)
70
450
Slope (dB/oct)
12
24
HPF *
Filter Shape
Butterworth
Linkwitz-Riley
Freq (Hz)
500
out
Slope (dB/oct)
48
LPF
Filter Shape
Linkwitz-Riley
Freq (Hz)
149
600
Level (dB)
+4
+3
Type
Parametric
Parametric
PEQ 1
Q/Bandwidth
3.0/0.479
8.54/1.71
Freq (Hz)
278
2100
Level (dB)
-6
-2
Type
Parametric
Parametric
PEQ 2
Q/Bandwidth
2.4/0.597
5.04/0.286
Freq (Hz)
1220
4600
Level (dB)
-15
+4
Type
Parametric
Parametric
PEQ 3
Q/Bandwidth
5.04/0.286
2.0/0.714
Freq (Hz)
6000
Level (dB)
-3dB
Type
Parametric
PEQ 4
Q/Bandwidth
3.6/0.40
Freq (Hz)
12000
Level (dB)
+4
Type
Parametric
PEQ 5
Q/Bandwidth
5.04/0.286
-40
-30
-20
-10
0
10
10
100
1000
10000
100000
LF
MF/HF
Electrical Transfer Function - Biamp VQ 60
Frequency (Hz)
Level (dB)