INTRODUCTION

Thank you for purchasing the Tannoy TX2 loudspeaker system controller.

The TX2 is an advanced electronic controller intended to optimise the performance
of Tannoy loudspeaker systems. It can be used in full range mode where it performs
equalisation functions, extending the low frequency response of the system
significantly. Also, it can be switched to 2-way active mode for applications requiring
greater capability at very low frequencies, where it provides a mono sub channel
output with optimised high and low pass internal crossovers.

The TX2 also features :

 stereo operation.

 balanced inputs and outputs.

 individual sub level control.

 high pass filters to protect against hazardous ultra low frequencies.

 industry standard 19’’ rack-mounting

As well as technical specifications, this manual contains some helpful advice on how
to use the controller. Thank you for taking a few minutes to read it prior to
installation.

OPERATING INSTRUCTIONS

Preliminary advice and information.

The information contained in this manual is relevant for all TX2 controllers although
versions will vary with different internal adjustments for equalisation or cross-over
sections. Each version is dedicated for use with a specific Tannoy loudspeaker
system. Make sure that the controller you are planning to use is suitable for your
loudspeakers, as degradation of the sound quality and unreliable operation could
result from an improper combination.

Please inspect the unit immediately after unpacking for signs of transit damage. In
the unlikely event that this has occurred please inform the carrier and the supplier. It
is always a good idea to keep the carton for possible future transportation.

Before the TX2 is connected to the mains supply, make sure that the unit is
selected for operation with the correct mains voltage
. This can easily be checked
by looking at the rear panel, where the selected input voltage appears on the voltage
selector itself, located near the mains socket. Where necessary, change the selection
by sliding the switch to the correct position. The position marked 115V is suitable for
any mains voltage from 100V to 120V, whereas the position marked 230V will suit
any voltage between 220V and 240V.

Figure 1. TX2 back panel

Summary of Contents for TX1

Page 1: ...ELECTRONIC LOUDSPEAKER SYSTEM CONTROLLER TX2 USER MANUAL ...

Page 2: ...NS 2 Preliminary advice and information 2 Input connections 3 Output connections 3 Operation with and without a sub bass system 3 SERVICING 5 Fuse replacement 5 List of spare parts 5 Warranty 5 TECHNICAL SPECIFICATIONS 6 Declaration of Conformity 7 ...

Page 3: ...his manual is relevant for all TX2 controllers although versions will vary with different internal adjustments for equalisation or cross over sections Each version is dedicated for use with a specific Tannoy loudspeaker system Make sure that the controller you are planning to use is suitable for your loudspeakers as degradation of the sound quality and unreliable operation could result from an imp...

Page 4: ... 3 pin male XLR connectors on the rear panel Two of them marked L for left and R for right are the output channels for the main system while the third one marked MONO SUB OUT is for the optional sub bass system On each of these connectors the signal is applied between pins 2 and 3 and pin 1 is grounded When devices connected at the input e g console and at the output i e amplifier are both balance...

Page 5: ... an optimised acoustic summation for the sub bass system On the sub bass channel signals from both left and right inputs are summed together and the resulting mono signal is low pass filtered before being sent through the level control section To sum up the push button should be in when a sub bass system is used out when not However it should be noted that the sub bass channel itself is not affect...

Page 6: ...tion please refer to the Service Manual or consult your local dealer or distributor PART NUMBER DESCRIPTION 6481 0273 TX2 User Manual 6883 0096 TX2 Front Panel 6883 0093 TX2 case Chassis 6883 0095 TX2 case Top cover Warranty No maintenance of the controller is necessary All Tannoy electronic components are guaranteed for a period of one year from the date of manufacture subject to the absence of o...

Page 7: ... 6dB Mains supply IEC mains connector with integral fuse holder Voltage selector for 115V or 230V operation 50 60Hz Fuse type 5 x 20mm rating T32mA 250V for 230V operation T63mA 250V for 115V operation Dimensions 1U high 19 rack mount width 44 5 mm H x 482 mm W x 150 mm D Weight 1 7 kg Tannoy operate a policy of continuous research and development The introduction of new materials or manufacturing...

Page 8: ...ed levels allowing radio and telecommunications equipment and other apparatus to operate as intended and the apparatus has an adequate level of intrinsic immunity to electromagnetic disturbance to enable operation as specified and intended The apparatus complies with the Principal Elements of the Safety Objectives of the Low Voltage Directive 73 23 EEC Details of the Apparatus Tannoy Active Crosso...

Page 9: ...428230 Internet http www tannoy com TGI Tannoy 300 Gage Avenue Kitchener Ontario CANADA N2M 2C8 Telephone 519 745 1158 Fax 519 745 2364 Tannoy Nederland BV Anthonetta Kuijlstraat 19 3066 GS Rotterdam THE NETHERLANDS Telephone 010 2860554 Fax 010 2860431 Tannoy is a member of the Group of Companies Issue 2 Part No 6481 0273 GH 30th March 1998 ...