Please read this Instruction Manual carefully and keep it 
for future reference.

ELECTRONIC SCALE

WB-150MA

Instruction manual

Temperature

:  

5°C – 35°C

Relative Humidity

:  

30% – 80%

(no condensation)

Maximum Altitude

:  

3,000m ASL

Pressure

:  

86kPa –106kPa

Temperature

:  

-10°C – 60°C

Relative Humidity

:  

10% – 90% 

(no condensation)

<Storage Conditions>

<Usage Conditions>

To avoid malfunctions, avoid storing the equipment in a location that is subject to 
direct sunlight, significant temperature changes, dampness, large amounts of dust, 
the risk of vibration or impact, or near naked flames. 

Summary of Contents for WB-150MA

Page 1: ...ative Humidity 30 80 no condensation Maximum Altitude 3 000m ASL Pressure 86kPa 106kPa Temperature 10 C 60 C Relative Humidity 10 90 no condensation Storage Conditions Usage Conditions To avoid malfunctions avoid storing the equipment in a location that is subject to direct sunlight significant temperature changes dampness large amounts of dust the risk of vibration or impact or near naked flames ...

Page 2: ... can be used to certify weights and or business transactions It can be used to obtain reference data during medical examinations such as peri odic checkups and can help the prevention of obesity Measurements can be taken quickly and easily causing minimal inconvenience to the patient during measurements ...

Page 3: ...stallation of the Equipment Remote Display Version Installation of the Equipment Column mounted version 12 Preparing the Power Supply Before use 3 Operating Instructions 13 Preparation Automatic power off to save battery life 13 Preparation Weight Lock Mode 14 Preparation Confirmation Software Version Number 14 Measuring Weight 15 How to use 4 Output Data Format 18 5 Troubleshooting 19 Specificati...

Page 4: ...wired outlet Only genuine cables and equipment can be used Do not use a multi plug adapter Doing so may cause fire Failure to follow instructions highlighted with this mark could result in death or severe injury Failure to follow instructions highlighted with this mark could result in injury or damage to property Keep this equipment away from flammable gas and oxygen rich environments This section...

Page 5: ...d unplug the AC Adapter from the wall socket If the equipment will be out of use for a prolonged period remove the batteries before storing the equipment The data provided by this equipment should be interpreted by a licensed professional Be sure to clean the scale platform with the appropriate disinfectant after each use Prohibited Always If an anomaly in the user or equipment is discovered take ...

Page 6: ...lectrodes etc for wear or damage Documentation for the current equipment model 3 Visually inspect the following at least monthly Screws on equipment Do not wipe the equipment with corrosive chemicals benzene cleaner etc Please use a neutral detergent to clean the equipment The warranty will be invalidated if an unauthorised person attempts to disassemble or repair any of the parts of this equipmen...

Page 7: ...sing dry cell batteries When using the AC Adapter Loosen the screw to slide the Battery Compartment out In case of emergencies keep the area around the outlet clear while operating this equipment GB Before use How to Measure Correctly ...

Page 8: ...splay Box Battery Compartment Platform Adjustable Feet AC Adapter MODEL FW7333SM 09 Instruction Manual Fixing Screw for the Bracket x 2 Accessories Accessories Battery Compartment Platform Adjustable Feet AC Adapter MODEL FW7333SM 09 Instruction Manual Screws x 3 Column Mounted Version Level Gauge Display Box GB Before use Product Assembly and Components ...

Page 9: ...f manufacture Follow operating instructions 9 Control Panel STEP ON Start measuring weight Net Net PT Indicates that the tare value is input Weight Lock Mode Indicates that the Weight Lock function is activated Weight Lock Indicates that the Weight is locked Stabilized Indicates that the displayed figure has stabilized Turn power ON Scale reset to zero Tare Decrease numerical value Turn Weight Loc...

Page 10: ...measurement place the equipment on as flat a surface as possible and adjust the level with the adjustable feet so the bubble in the level gauge is in the centre of the frame Pull out the stand at the back of the display box When putting away the display box insert the stand in the slot on the back of the display box There is a danger that the Display Box may fall down if it is not fixed securely A...

Page 11: ...e column before use Connect the connectors on the platform and column Turn the platform over Screw the column to the platform using three screws Insert the connector into the column 2 1 3 4 2 1 3 4 Ensure that the cable does not become wrapped around the screws Note GB Before use Product Assembly and Components ...

Page 12: ...If the polarity is incorrect the batteries may leak and damage the equipment Remove the batteries before storing the equipment if it is not to be used for a long time Insert the AC adapter jack into the DC jack socket of the Display Box and insert the AC Adapter plug into a wall socket Check that the Pilot Lamp on the AC Adapter lights Unscrew the Fixing Screws for the Battery Compartment on the r...

Page 13: ...ave battery life Press when there is nothing on the scale is displayed Press while is displayed and select the automatic power off time by pressing or After selecting the automatic power off time press to set the input time When is displayed the setting is completed 5minutes 10minutes 30minutes 60minutes Inactivate How to use Operating Instructions GB Turn on the power by pressing After flashes is...

Page 14: ...hen the weight lock mode is enabled Weight Lock Mode mark is indicated in the display When the weight lock function is enabled the measurement value is locked after the load is stabilized When the weight is locked the Weight Lock mark is indicated in the display 1 2 3 Preparation Confirmation Software Version Number Press when there is nothing on the scale is displayed Select by pressing or Press ...

Page 15: ...ntre of the platform After load is stabilized Stabilized mark is indicated Step off the scale When use Preset Tare functions Press in no load Net PT mark PT mark and flushes Input preset tare value by or within 20 0kg 0 1kg increments Set input preset tare value by Turn on the power by pressing After flashes is displayed 1 Turn on the power by pressing After flashes is displayed 1 2 3 4 5 2 3 or ...

Page 16: ...cancelled temporarily is displayed When inactivate preset tare function please set preset tare value to 0 0kg Press in using preset tare Input preset tare value by or within 20 0kg 0 1kg increments Net PT mark and PT mark are displayed Set input preset tare value by To change preset tare value Measuring Weight continued 1 2 1 2 or ...

Page 17: ...s the key An arrow NET will appear next to the mark and 0 0kg will be displayed When weighing a person object including tare items the weight of the person object minus that of the tare items which is the net weight will be displayed To change the tare weight cancel the tare weighing function and repeat from step 3 When using the tare weighing function the measurement range is reduced by the tare ...

Page 18: ...ion Explanation for RS 232C compliant output 18 GB Specifications Communication standard EIA RS 232C Communication method Asynchronous Signal speed 9 600bps Data bit length 8bit Parity NONE Stop bit 1bit Terminator CR LF Flow control None Signal line name and connection method Terminal no Signal name 1 2 TXD 3 Connection example WB 150MA PC etc 4 5 GND 6 7 8 9 This explanation is for the interface...

Page 19: ...teries The batteries may have run out Confirmthat the equipment is working by using the AC Adapter or new batteries 5 Troubleshooting 19 Transmission data GB Transmission data is output immediately after measurement regard less of the status of the reception side e g PC Therefore the reception side must always be ready to receive data before any measurements are taken Commas are used to separate d...

Page 20: ...ita co jp www tanita co in A 502 Mittal Commercia Off M V Road Andheri Kurla Road Marol Andheri East Mumbai 400 059 INDIA Tel 91 22 3192 6107 Fax 91 22 2859 9143 Shanghai Trading Co Ltd Power Source AC adapter FW7333SM 09 CLASS Ⅱ Input Voltage 100V AC 240V AC 50 60Hz 200mA Output Voltage 9V DC Rated Current 800mA Plug Type Centre Minus Internally Powered Equipment Battery Mode LR6 AA Alkaline batt...

Reviews: