For Your Safety

Prohibited

Warning

Ignoring instructions highlighted with this mark could result in
death or severe injury.

Caution

Ignoring instructions highlighted with this mark could result in
injury or damage to property.

This mark indicates actions that are prohibited.

This mark indicates instructions that must always be adhered to.

Warning

Caution

The following outlines precautionary measures to be taken to avoid injury to the users of this device
and others, and to prevent damage to property. Please familiarise yourself with the contents to
ensure the safe operation of this equipment.

Take care near water.

To  avoid damage, do not use this device near water or other
places where it may get wet.

This device must not be used on subjects with pacemakers or
other mechanical implants.

This device passes a weak electrical current through the body
which could interfere with and cause the malfunction of electrical
medical implants, resulting in serious repercussions.

To avoid injury, do not insert fingers into gaps and holes.

Avoid impacts on the display.

The acrylic screen may split and cause injury.

Quickly remove moisture from the display screen to avoid, deformity, colour
change, staining and fading.

Wipe over the impedance meter electrodes with disinfectant (alcohol, etc.) prior
to measuring.

This is to avoid the transmission of disease when the meter is placed on the
abdomen.

Use only the dedicated AC adapter and cord.

The use of other adapters/cords may result in damage or fire.

Ensure disabled persons do not attempt to use the equipment by themselves.

A companion must perform the measurements.

Continually monitor both the subject and the equipment for anomalies.

Should an anomaly with the subject or the equipment be discovered, take appropriate
action, such as stopping the equipment, while ensuring the safety of the subject.

Do not expose items sensitive to magnetic forces to the equipment.

Exposing items that may be affected by the magnetic force of the magnet on the
impedance meter (floppy disks, USB memory sticks, etc.) may result in corruption of
data.

Avoid using on subjects with allergies to metals.

Allergic reactions may be caused by the stainless steel used in the electrodes of this
device.

This device must not be used on women who are pregnant or
may be pregnant as the foetus may be affected.

Do not dismantle or modify.

There is a risk of electrocution or injury. Nor can precise analysis
be guaranteed.

Do not use double adapters.

May result in fire.

Do not interpret analysis results yourself (including evaluating
measurements and formulating exercise programmes based on
results, etc.).

Weight loss and exercise based on self-analysis could be
detrimental to your health. Always follow the advice of a qualified
professional.

Do not shine the laser beam directly into the eyes.

Damage to eyesight may occur.

always adhere to the following

Prohibited

Always…

Summary of Contents for ViScan AB-140

Page 1: ... AB 140 Abdominal Fat Analyser Misuse of this device may result in a serious accident Please ensure that you read this Instruction Manual thoroughly prior to use and store it in a convenient location for easy reference N B 2008 TANITA Corporation All Rights Reserved AB1407601 0 ...

Page 2: ...pedance Analysis BIA method to directly measure the abdomen of a subject in the supine position With this method the previously difficult task of managing the health of people who are unable to stand or are otherwise disabled becomes possible The AB 140 also has the latest reactance technology functions which allows analyses to reflect cellular changes in the abdominal cavity and individual differ...

Page 3: ...transmission of disease when the meter is placed on the abdomen Use only the dedicated AC adapter and cord The use of other adapters cords may result in damage or fire Ensure disabled persons do not attempt to use the equipment by themselves A companion must perform the measurements Continually monitor both the subject and the equipment for anomalies Should an anomaly with the subject or the equip...

Page 4: ...allow to stand for at least 2 hours before using Wet the area of the abdomen to which the electrodes are to be attached and ensure correct positioning To wet lightly wipe the area with moistened cotton wool or a damp cloth Due to the influence of the state of the skin and body hair etc abnormally high readings and measurement errors may occur if the device is used without wetting the area Use in a...

Page 5: ...be accommodated by with the main unit shifts to calibration mode when pressed for 2 seconds or more Power key Press to turn on and off Measure key Battery level Press to begin measuring Charging LED Green light comes on when the AC adapter is connected light goes off when charging is completed Gender selection key Press to select subject gender Carry bag Distance measuring sensors Power LED Infrar...

Page 6: ...ies in accordance with the regulations of your local governing body 2 Loosen screws 3 Turn over to front side and remove the cover 1 Turn over Image only Please Charge the battery immediately after purchase The main unit cannot measure during charging Remove the AC adapter from the main unit when taking measurements moving the main unit charging is complete 4 Insert batteries 1 Insert the AC adapt...

Page 7: ... as shown in the diagram above As the distance sensor measures the breadth of the abdomen ensure that no clothes or elbows impinge on the 10cm area centred on the navel Do not allow the distance sensors to come into contact with the abdomen Refer to page 21 Waist Circumferences Over 130cm when contact is unavoidable due to a large waist or when the main unit cannot accommodate the size of the abdo...

Page 8: ...s been selected 5 Blue print in display illustrations indicates parts that illuminate or flash Blue print in display illustrations indicates parts that illuminate or flash 2 Once the gender has been selected the screen will change as shown At this time the red Laser On LED will light up and the laser in the main unit will operate To change the gender selection turn the power off then re select Mea...

Page 9: ...e laser directly towards the eyes as this may cause damage to eyesight Please Have the subject breathe normally while measurements are being taken Do not allow the distance sensors to come into contact with the abdomen Refer to page 21 Waist Circumferences Over 130cm when contact is unavoidable due to a large waist or when the main unit cannot accommodate the size of the abdomen For Your Reference...

Page 10: ...indicates parts that illuminate or flash Warning Do not direct the laser directly towards the eyes as this may cause damage to eyesight Please To wet wipe lightly with moistened cotton wool or other cloth Please Check that the green Power LED is illuminated when positioning the impedance meter The impedance meter Power LED will automatically turn off when more than approximately 10 minutes passes ...

Page 11: ...anger on the main unit hook Press the key on the main unit to turn on The initial screen is displayed This mode allows measurements to be easily taken when the waist of subject is too big to be accommodated by the main unit Place the main unit close to the supine subject as shown in the diagram below The main unit will switch off automatically after two minutes in the absence of any operation 1 Pr...

Page 12: ...ositioned close by remote controllers for televisions etc are used near the impedance meter or the main unit the batteries have expired the impedance meter is outside the infrared ray communication range see diagram at right the communication distance is changed due to the effect of lighting appliances 25cm Please To wet wipe lightly with moistened cotton wool or a damp cloth Please Check that the...

Page 13: ...Item Format Content Output Order Standard Over 130cm Control data 0 Fixed at 16 1 5 byte variable length 1 1 Control data 0 Fixed at 1 1 5 byte variable length 2 2 Control data 1 Fixed at 1 1 5 byte variable length 3 3 Control data 2 Fixed at 1 1 5 byte variable length 4 4 Model number MO AB 140 8 byte fixed length 5 5 Gender GE 1 or 2 1 byte fixed length 1 Male 2 Female 6 6 Trunk fat FT XX X 3 4 ...

Page 14: ...n be addressed by calibrating the unit thus allowing accurate measurements to be taken again To Calibrate Correctly Calibrate on a flat stable surface Ensure no objects are between the distance sensors Calibrate at a temperature of 15 25 C Press the key on the main unit to turn on The initial screen is displayed 1 Blue print in display illustrations indicates parts that illuminate or flash No obje...

Page 15: ...lacing Please contact a Sales Office for a new battery See the last page for contact details Access battery from the bottom Battery housing Caution Never switch off the power while is displayed indicating the unit is calibrating Calibration cont d The battery in the main unit is a consumable item The battery must be replaced when the charge soon runs out even after lengthy recharging Remaining bat...

Page 16: ...ing down Ensure the equipment is not exposed to any strong impact as this may cause damage Take care not to drop the equipment when removing from the carry bag as this may cause damage 30 How to Use 1 Remove the single screw from the bottom of the battery housing and push up the lid 2 Draw out the connector 3 Remove the battery 5 Connect the connector of the new battery to the main unit and insert...

Page 17: ...d through actively engaging in exercise and food restrictions Please see a medical practitioner for a medical diagnosis Very High 5 3 High No need for concern at present Continue with a balanced diet and an appropriate amount of exercise Average 1 18 0 20 0 13 0 15 0 1 0 6 0 2 6 5 12 5 4 15 5 17 5 6 20 5 and more Determination Interpretation Visceral fat levels measured by this unit It is possible...

Page 18: ... immediately Check the AC adapter connection Nothing is displayed when the power is turned on The Charging LED does not light up even when charging has commenced Display 34 As Needed Troubleshooting Problem Try This Please try the following prior to arranging repairs Measu ring Impedance meter error Buzzer does not sound or or is displayed Store the impedance meter in the main unit to reset the im...