01/01/2016

Setting Up the Device

Select "Various Setting".

Select the setting option you wish to change.

When you are finished with the settings, select "Back" on the "Various 

Setting" screen. This will take you back to the initial screen.

Note 

(          P.21)

Select this option to set date and 

time to be printed on reports and 

to be recorded into the database.

Date and Time

Select this option to configure 

an external printer.

Printer

(          P.22)

Select this option to configure 

communication parameters.

PC Connection

(          P.24)

Select this option to connect 

external devices.

External Device

(          P.25)

Select this option to configure 

measurement options.

Measurement Mode

(          P.26)

Select this option to adjust 

brightness and other functions.

Controller

(          P.28)

How to Set Up

01/01/2016

Summary of Contents for MC-980MA-N PLUS

Page 1: ...86 to 106kPa Temperature Range Relative Humidity Range 10 to 90 non condensing Atmospheric Pressure Range 70 to 106kPa To avoid malfunctions avoid storing the equipment in a place with direct sunlight significant temperature changes a risk of dampness a large amount of dust or a risk of vibration or impact or in the vicinity of flames Please read this Instruction Manual carefully and keep it for f...

Page 2: ...ch as diabetes hyperlipidemia bariatric surgery hypertension and fatty liver disease monitoring increases of muscle mass reduction of body fat and hydration levels as part of a fitness or training program assessing the true effectiveness of nutrition and physical activity programs where body mass index cannot identify key changes in body composition collating subject data for large cohort research...

Page 3: ...Change Password 40 Measuring Body Composition 38 Measurement Flow 37 General Instructions for Measuring Body Composition 50 Taking a Measurement 54 Measuring Body Weight Only How to Use Assembling the Main Unit 9 Checking the Delivered Parts 8 Part Names Connection Procedure 14 55 Troubleshooting Other Information 56 Specifications ...

Page 4: ...ts with pacemakers or other mechanical implants Keep this equipment away from flammable gas and oxygen rich environments This device passes a weak electrical current through the body which could interfere with and cause the malfunction of electrical medical implants with serious consequences Do not handle the plug with wet hands This may result in electric shock fire or current leakage Do not use ...

Page 5: ...xercise programs based on results must be performed by a professional Weight loss measures and exercise based on self analysis could be harmful to your health Always follow the advice of a qualified professional This equipment is designated a Class B IT device mainly for systems intended to be used in indoor environments and is CE EMC certified but it may affect devices that are sensi tive to elec...

Page 6: ... bare and placed correctly on the electrode platform Arms should be straight down during measurement This may cause inaccurate measurements For greater accuracy avoid using directly after waking up Use at the same time of day each time at least three hours after the last meal Use in a stable location Errors in measurements may occur if the device is used in an unstable location Use the equipment u...

Page 7: ...ualified personnel before using again 1 Check the following at least daily Check that the unit is on a stable and level surface e g on firm flooring not on a thick carpet Date and time settings 2 Visually inspect the following at least weekly Inspect the display for any damage or contamination Inspect all cables cords and connector ends for damage or contamination Inspect all safety related labeli...

Page 8: ...it D E H I A B C D I J J K K L M M Column F G C B A J E F G H M InstructionManual thismanual TechnicalNotes QuickStartGuide Platform Cover Large Cover Small Display Unit Screws 6 pcs Communication Cable Power supply Cord AC Cord Clamps 2pcs Column Body Cover for Slit Display Cover Screwdriver Clamp and display cover are already installed to column body ...

Page 9: ...se the fastening screws on the cover small Pull up the cover and release the hook that fits the slit in the cover large Pull the two tabs at the right end and the left end of the cover large toward the outside and remove the cover Press the two tabs at each side of the display cover to detach it Two persons are needed to open the box and unpack the unit This is a heavy appliance and can cause inju...

Page 10: ...nication connector firmly into place Insert the communication cable and the power supply cord into the column slit Fix these two cables into place with the hook at the top of the column Insert the plugs for the power supply cord and the communication cable to the respective connector on the display unit Use the provided screwdriver to fix the communication connector firmly into place Firmly suppor...

Page 11: ...ides of the column Insert the cables from both grips into the slit on the column Fix the cables from both grips to the column using clamp as shown in the figure on the left This figure does not show the power supply cord and communication cable Insert the bottom of the display cover to the column and fix into place by it inserting both of the top tabs into the column J ...

Page 12: ...hen the cover so it faces right Forcing the cover may damage it Fit into place and lock the cover to the platform L 9 Cover the slit 10 Fix the pole cover large into place Do not insert your fingers into any gaps while assembling Doing so could cause your fingers to become caught or injured Warning ...

Page 13: ...ave now fully assembled the device Insert the cover small into the slit in the cover large Use the screws 2 pcs to fix the cover into place The screws are already attached to the cover small 11 Fix the cover small into place ...

Page 14: ...at the equipment is level Screws 6 pcs Instruction Manual this manual Technical Notes Quick Start Guide Communication Cable Power Supply Cord AC Cord Screwdriver Level Gauge Black ring Air bubble For accurate measurements place the machine as level as possible Rotate the adjustable feet 4 positions for adjustment until the bubbles in the level gauge are in the center 14 en ...

Page 15: ...FF Power Switch Display unit on Polarity of the DC power connector Computer network Serial interface See the instructions ON power OFF power Direct current Serial number General prohibition sign General mandatory action sign Warning Electrictiy Caution Risk of electric shock Alternating current Class II equipment Input output Caution Refer to the attached notes Type BF applied part Grips and platf...

Page 16: ... Various settings P 20 Database management settings P 29 1 3 Initial screen Connect the AC cord to the platform and plug it in to power outlet Turn on the power of the platform The initial screen is displayed Then turn on the power of the Display unit 01 01 2016 Turning On the Power ...

Page 17: ...se en 1 2 Select Setup and then select Shutdown or press the power button on the Display unit to turn off the power Turn off the power of the platform 01 01 2016 Power Supply Turning Off the Power MC 980MA N plus ...

Page 18: ...gency by removing the plug from the power outlet Make sure that there are no obstructions around the power outlet when using this equipment Power Supply Emergency Shutdown Do not turn off the power by removing the plug from the power outlet except in an emergency Note ...

Page 19: ...nter Page 22 PC Connection Page 24 External Device Page 25 Measurement Mode Page 26 Controller Page 28 Change Password 01 01 2016 01 01 2016 01 01 2016 Call up Member Data Page 30 Page 31 Output Measurement Result Page 34 Page 35 Data Backup Database Management Page 29 Page 36 Add Remove or Change Register New User Search Registered User Import User Data Export User Data 01 01 2016 ...

Page 20: ... set date and time to be printed on reports and to be recorded into the database Date and Time Select this option to configure an external printer Printer P 22 Select this option to configure communication parameters PC Connection P 24 Select this option to connect external devices External Device P 25 Select this option to configure measurement options Measurement Mode P 26 Select this option to ...

Page 21: ...P 20 For example to enter January 21 2016 2 1 0 1 0 1 6 2 Set the Date and Time Select any field to enter or edit information The field to edit will be highlighted For example to enter 9 43 AM 0 9 4 3 2 Time 1 Date 1 2 Select Back to stop entering information The date and time will not be changed and you will be taken back to the Various Setting screen Note ...

Page 22: ...m of the screen once the printing function is ON OFF No automatic printing 1 Prints 1 sheet at end of a measurement 2 Prints 2 sheets at end of a measurement 3 Paper You can select between pre printed sheets and printing blank sheets A4 size Pre printed form Dedicated sheets will be used for reports Plain paper Full color printing to a regular A4 clear sheet 1 2 3 4 5 6 7 This option allows printi...

Page 23: ...s will be displayed The check mark indicates the current printer Checking the box of another printer will change the selection to that printer 7 Printer Selection 6 Information You can set any text such as a name of a hospital gym etc to be printed on the measurement report Select Back to stop entering information The date and time will not be changed and you will be taken back to the Various Sett...

Page 24: ...e and a PC Select PC Connection 1 Baud Rate Select from 4800 9500 or 19200 2 Flow Control Select from OFF Hardware or Xon Xoff Select Back to stop entering information The date and time will not be changed and you will be taken back to the Various Setting screen Note After configuring all settings select OK to save and return to the Various Setting screen P 20 ...

Page 25: ... touch screen NFC Select this to use an NFC reader Optional function Barcode Select this to use a barcode reader Optional function Select the number of characters in the barcodes to be used Select Back to stop entering information The date and time will not be changed and you will be taken back to the Various Setting screen Note After configuring all settings select OK to save and return to the Va...

Page 26: ...ase after each measurement Serial No Automatic Starts at 1 The user number will automatically increase after each measurement Turns Athletic Mode ON OFF P 37 OFF Disables Athletic Mode ON Enables Athletic Mode This displays additional details muscle mass parameters P 51 in the Measurement Result OFF The additional information button is not displayed ON The additional information button is displaye...

Page 27: ...nd outputs You can change reference the BMI range as needed Default range 18 5 to 24 9 Change numbers by pressing or 5 Output Type 6 BMI Normal Range 5 6 Select Back to stop entering information The date and time will not be changed and you will be taken back to the Various Setting screen Note After configuring all settings select OK to save and return to the Various Setting screen P 20 ...

Page 28: ...p OFF Does not beep on touch ON Beeps on touch 3 Vibration mode The language is selected on the Main Menu screen The display will switch to the selected language 01 01 2016 1 2 3 Makes the screen darker Makes the screen brighter OFF Does not vibrate on touch ON Vibrates on touch Select Back to stop entering information The date and time will not be changed and you will be taken back to the Various...

Page 29: ...rd P 31 You can also acquire data using data management application software 3 Output Measurement Result Output data stored internally in CSV format P 34 4 Data Backup Makes a backup file at specified location P 35 Note When you are finished with the settings select Back Managing the Database Database Management 1 2 3 4 MC 980MA N plus ...

Page 30: ... and giving workout guidance 01 01 2016 Recall stored measurement result data Input a user ID name or measurement date and select Search If you search without inputting any data all of the stored measurement results will be displayed If you enter multiple criteria all data that meets the search conditions will be displayed Choose a data item and select View 01 01 2016 ...

Page 31: ...all other personal information and press Register September 24th 1973 24 09 1973 Example e Type Select Standard Mode Athletic Mode Athletic Mode P 37 f Height Enter a height between 90 0 and 249 9cm g Password Enter a number with a maximum of 10 digits Password is optional a b c d e f g 01 01 2016 d Gender Select the gender Note Duplicate ID numbers are not accepted a ID Enter a maximum of 16 alph...

Page 32: ...er the ID of the desired record 2 Enter new data After entering all digits of the ID select Enter or Search The corresponding data will be displayed Select a field and change it P 44 When you have finished inputting the information select Enter to update the field ...

Page 33: ...f the entry you want to delete After entering all digits of the ID select Enter or Search The corresponding data to be deleted will be displayed 2 Delete data Select Delete to have the data deleted When you are finished deleting select Back ...

Page 34: ...lect Search The search result will be displayed The search result will not be available if there are over 100 matches If this occurs change the range and search again 2 Output data Check the data and select CSV Output 3 Choose the destination folder and file name Then select Save Managing the Database continued ...

Page 35: ...35 en How to Use Data Backup Choose a destination for the backup file and press OK Select Data Backup ...

Page 36: ...36 en How to Use Change Password 1Select Setup 4Enter the new password 01 01 2016 01 01 2016 2Input the password then select Enter Initial password 9999 01 01 2016 3Select Change Password 01 01 2016 ...

Page 37: ... vascular exercise a week or exercise for 12 hours or more per week People who belong to a sports team or a sporting organization with the aim of participation in competitions etc Professional athletes Inaccurate results may occur after excessive food fluid intake or after periods of intense exercise If the clothes weight is input the clothes weight is subtracted from the weight measurements Stand...

Page 38: ...38 en How to Use Measurement Flow Initial screen Enter an ID Measure body weight Single measurement Member measurement ...

Page 39: ...39 en How to Use Confirm the entered details and measure body weight Measure body composition Enter personal information The measurement results are displayed 69 5 ...

Page 40: ...even without setting the clothes weight Displays your weight minus the clothes weight When the measurement result is heavier than 2 0 kg and becomes stable the screen will automatically switch to Enter user number Select Data input to enter the required fields before body weight measurement You can hide body weight from the display If you turn on Clothes weight the Tare sign will be displayed The ...

Page 41: ... screen will be displayed 4 Select gender 5 Select body type Note Note on Athletic Mode P 37 The Select body type feature is not available in the following cases The user is younger than 18 years old Athletic Mode is set to OFF the body type will be Standard Athletic Mode is set to AUTO the body type will be automatically selected 69 5 69 5 ...

Page 42: ...asurement to measure body composition If you want to store all of the data as a user record select New User Registration P 44 Use the number keys to enter the user s height Select Enter This will cause the screen to switch to Set target body fat 6 Enter age 7 Enter height 8 Set target body fat Note You can enter an age from 5 to 99 Users over 100 years old should enter 99 Users younger than 18 yea...

Page 43: ...asurement Note If you entered the data previously the impedance will be measured after body weight 12 The result will be displayed Adult Child The correct position for measurement Note For some settings the data will also be transferred automatically from the output port Select the button at the bottom of the screen to show information on each of the items P 50 Select Quit then select Yes on the c...

Page 44: ...D to start measuring You can create a new record for the past to observe your fitness progress or to measure the same users again Member s Measurement Measuring Body Composition continued Select New User Registration Input the user s ID name and other personal information and select Register 3 Enter the ID to be set as the user number Use the keyboard to enter the ID and press Enter 01 01 2016 ...

Page 45: ...y month year format Press Enter after input to confirm 6 Select gender Choose gender by selecting one of the displayed gender buttons Female or Male Note You can enter name with up to 16 characters Note The oldest year of birth that can be registered is 1900 Users aged 100 or over are registered as 99 years old Example September 24th 1973 24 09 1973 ...

Page 46: ...dy type Note Note on Athletic Mode P 37 The Select body type feature is not available in the following cases The user is younger than 18 years old Athletic Mode is set to OFF the body type will be Standard Athletic Mode is set to AUTO the body type will be automatically selected 8 Enter height Note You can enter a height from 90 0 to 249 9 cm 9 Enter password Optional Note You can use a number com...

Page 47: ...istered a password Note You can skip impedance measurement if necessary You can recall stored individual data to avoid re entering data before another measurement This function also allows you to browse past measured results Member s Measurement Rendering Individual Data From the Second Time Step onto the analyzer with bare feet 01 01 2016 01 01 2016 01 01 2016 Use the number keys to enter the pas...

Page 48: ...ment Press Recall data before body weight measurement Measuring Body Composition continued Follow the instructions on screen to measure body composition 4 Start measurement Hold the grip handles gently and put your arms naturally by your sides Stand evenly on the electrodes under your toes and heels Adult Child The correct position for measurement ...

Page 49: ... show information for each of the items P 50 Select Quit then select Yes on the confirmation screen You will be taken back to the Weight screen P 47 The result will be stored automatically once the measurement is completed 5 End measurement 6 Displaying the results Return the grip handles 7 Check details Select the Details button to display the details 69 5 ...

Page 50: ...at that counts towards body mass Desirable The standard value is for the Standard mode When Athletic Mode is used the standard value is used for reference Target Predicted weight and fat mass are displayed according to the set target BF Previous Displays the difference with the previous result Initial Displays the difference with the initial result Bone free lean tissue mass LTM Entire amount of b...

Page 51: ...M Appendicular Skeletal Muscle Mass MM H2 Whole body muscle mass Height m 2 MM BW Whole body muscle mass Body Weight SMI Total muscle mass value of right arm left arm right leg and left leg Height m 2 Total muscle mass value of right arm left arm right leg and left leg BodyWeight ASM BW 01 01 2016 Measurement Results continued Taking a Measurement Additional Information ...

Page 52: ...centage of extracellular water in relation to the total body water ECW TBW 01 01 2016 Balance Leg Muscle Score A score is given to the user s physical condition and plotted against average healthy values for the user s gender and age The score is based on the user s leg muscle mass divided by their body weight For example a healthy 20 to 25 year old should achieve a score of 100 Balance Muscle Mas...

Page 53: ...upper to lower body fat is calculated and plotted against average healthy values for the user s gender and age Balance Physique Rating Gives a rating for the user s body type taking into account the proportions of fat and muscle in their body History Displays the measurement result trends 01 01 2016 01 01 2016 01 01 2016 Measurement Results continued Taking a Measurement ...

Page 54: ...unavailable To change the clothes weight press Clothes weight PT P 40 The entered weight will be shown in a negative value Select Back to be taken back to the previous screen Measuring Body Weight Only 1Select Weight Only on the initial screen 2 Enter the user number 3Get on the platform Select Enter This will cause the Weight Only screen to be displayed If this item is not displayed it is because...

Page 55: ...d Is something blocking the gaps in the measuring platform Remove any inserted objects Nothing is displayed even when the power is turned on Touch panel screen display is dark Confirm that the power is connected correctly Backlight failure Contact the retailer where you purchased the analyzer is displayed The weight to be measured exceeds the maximum capacity Display Hold the handgrips and electro...

Page 56: ...k 75 0 to 1 500 0Ω 0 1Ω increments 2 Strain gauge load cell 300kg including preset tare value 0 1kg 0 2kg 10 4 TFT color LCD touch panel USB Type A Port USB host x3 USB Type B Port Device x1 LAN port x1 Platform Product Platform size 450 x 490mm Height 65mm Height 1240mm 33kg Input Items Single Measurement Clothes Weight Serial No Gender Body Type Age Height Target Body Fat Registered User Clothes...

Page 57: ... 0 1 increments 0 1kg increments 0 1kg increments 12 to 90 1 increments 1 to 59 1 increments 0 1kg increments 0 1 increments 0 1kg increments 0 1kg increments 0 1 increments 0 1kg increments 4 to 4 1 increments 1 0 to 75 0 0 1 increments 0 1kg increments 4 to 4 1 increments Whole body Muscle Mass kg Height m 2 Whole body Muscle Mass kg Body Weight kg Total muscle mass value of Right arm Left arm R...

Page 58: ...ast Mumbai 400059 Maharashtra India TEL 91 771 801 1511 91 771 801 1382 FAX 852 2838 8667 www tanita co in TANITA India Private Limited Room 8005 877 Huai Hai Zhong Lu Shanghai The People s Republic of China TEL 86 21 6474 6803 FAX 86 21 6474 7901 www tanita com cn TANITA Shanghai Trading Co Ltd Unit 301 303 Wing On Plaza 3 F 62 Mody Road Tsimshatsui East Kowloon Hong Kong TEL 852 2834 3917 FAX 85...