5) Once the pairing process is completed with the platform, the remote display 

shows "donE" and then the clock will be displayed. If the remote display 
shows “ P-Err ”, please try the pairing process again.

Note :  To confirm the paired serial number on each personal nuber after completion the pairing process:

Press and hold the SET button for 2 seconds on the remote display. The remote display will show "-1-". Select the per

-

sonal number using 

s

/

t

 buttons, and press the SET button to confirm. The display shows the paired serial number for 

3 seconds. "-----" is shown if there is no serial number stored for selected personal number.

Setting and storing personal data in the remote display

You will receive readings only if data has been programmed into the Tanita remote display.

1.  Select Personal Data Number

Use the SET button to activate the unit. Use 

s

/

t

 buttons to select a personal data number. Press SET button.

2. Set Age (Applicable Age: 7 - 99)

Use 

s

/

t

 buttons to select age. Press SET button.

3. Select Female or Male (Applicable Athlete Age: 18 - 99)

Use 

s

/

t

 buttons to select Female / Male / Athlete Female / Athlete Male. Press SET button.

4. Specify  Height

Use 

s

/

t

 buttons to select height. Press SET button to confirm.

The remote display will beep twice and the display will flash all data three times to confirm the programming.

The power will then shut down automatically.

Taking body composition readings

1.  Before proceeding, make sure that the platform and remote display are within 17 feet (5 m) of each other.
2.  Press 

t

 (User) button to turn the unit on and then press 

s

/

t

 buttons to select personal data number.  

(

Do not stand on the platform

.)

3.  Press the SET button to confirm your personal number.
4.  When the remote display and platform are paired, the platform will beep 

once, and the Green Indicator Light on the platform will blink.

5.  Step onto the platform while the Green Indicator Light is blinking.
6.  After the measurement is complete, the platform will beep twice, readings 

will automatically show on the remote display (Refer to fig. 1).

7.  Carefully step off platform after measurement is complete.
8.  At anytime during and after the “Auto Display Process”, the user may use 

s

/

t

 buttons to scroll through the different results. For advanced scrolling, 

the user may press and hold 

s

/

t

 button. 

  Upon reading the desired readings, release the button to view the result, 

readings will appear for 30 seconds before the unit automatically shuts off.

Note

: For children (age 7-17), the unit will only display the Weight and the Body Fat % (it will not display the Healthy Range 

Indicator).

Weight
Body Fat %
Body Water %
Muscle Mass
Physic Rating
BMR or DCI
Metabolic Age
Bone Mass
Visceral Fat Rating




n/a
n/a
n/a
n/a
n/a

BC-1100F Displayed Readings

fig.1

Summary of Contents for FitScan BC-1100F

Page 1: ...Model FitScan BC 1100F MANUAL Instruction Manual Read this Instruction Manual carefully and keep for future reference ...

Page 2: ...onitor is intended for adults and children ages 5 17 with inactive to moderately active lifestyles and adults with athletic body types Tanita defines athlete as a person involved in intense physical activity of approximately 10 hours per week for at least 6 months and who has a resting heart rate of approximately 60 beats per minute or less Tanita s athlete definition includes lifetime of fitness ...

Page 3: ...oid soaps Do not step on the platform when wet Do not drop any objects onto the platform Do not use this scale while operating transmitters such as a cell phone as this may affect your results If not in use for a prolonged period of time it is recommended that you remove the batteries Getting accurate readings To ensure accuracy readings should be taken without clothing and under consistent condit...

Page 4: ...m of each other 2 Press and hold OFF button for 2 seconds on the remote display The remote display will show 1234 for selecting a personal number Select the preferred personal number which will be paired with the platform using s t buttons and press the SET button to confirm 3 The remote display will show SEt P Select YES or no using s t buttons and press the SET button to confirm a YES The pairin...

Page 5: ...ash all data three times to confirm the programming The power will then shut down automatically Taking body composition readings 1 Before proceeding make sure that the platform and remote display are within 17 feet 5 m of each other 2 Press t User button to turn the unit on and then press s t buttons to select personal data number Do not stand on the platform 3 Press the SET button to confirm your...

Page 6: ...ea Do not step onto the platform before the platform beeps once and the Green Indicator Light blinks Do not step off until after hearing a double beep or the Green Light remains solid stops blinking the measurement is taken and the readings are displayed on the applicable device e g Tanita Remote Display and or PC If you do not step onto the platform within 30 seconds after Green Indicator Light b...

Page 7: ... found to comply with the limits for a Class B digital device pursuant to part 15 of the FCC Rules These limits are designed to provide reasonable protection against harmful interference in a residential installation This equipment generates uses and can radiate radio frequency energy and if not installed and used in accordance with the instructions may cause harmful interference to radio communic...

Reviews: